4.11 Attendance and maintenance, fault clearance
Attendance and maintenance
Check the filter for contamination regularly. The interval depends on the water
quality.
Attention! The filter cartridges can be blocked! In extreme case the water can not flow
anymore!
Inspect the whole drinking system of leakages between the circles. Also inspect the
nipples. Should there be more than two drops within five minutes, the drinking line
should be cleaned. We suggest EVC 12 for the cleaning between the passages. EVC
12 is available from us.
At using the automatical flush system you have to check the correct position of the
connection to the magnetic valve. Check the cables in the hutch of damaged
isulation.
Trouble shooting
Trouble
reason / corrective
Flooding of the cup
Contamination of the valve seat in the nipple. Clean the
valve seat and change the nipple if necessary!
Pendulum clamps. Pendulum is too hard to move. Take
away the Pendulum and clean the Pendulum and the
intake!
Cup is empty
Accumulation at the nipple. Clean the nipple!
Pendulum clamps. Pendulum is too hard to move. Take
away the Pendulum and clean the Pendulum and the
intake!
Insufficient water
absorbtion of the
animals
The drinking line is adjusted too high. Check the height
adjustment according to the hight table (page 36).
Insufficient water
pressure at the
Breather Unit
The water pressure is too low. Check the water supply!
Look after the water filter because of accumulation!
Wet litter
The drinking lines are to low. Check the height adjustment
according to the hight table (page 36).
Accumulation staying
at the edge of the cup
The drinking lines are to low. Check the height adjustment
according to the hight table (page 36).