Alfa LU-VE reserves the right to change specifications without prior notification. 

Cold parts. Danger of frostbite injuries. 

Wear adequate protection.

Risk of injuries. 

Wear protective gloves.

A3 flammable gas.

1.5  Health, safety and hygiene

Ensure that the following guidelines are observed:

•   All work on the equipment must be carried out by trained personnel.

•   The electrical supply is suitable for the equipment supplied.

•  Refrigerant, temperature and pressure must agree with the data on the product label of the 

relevant heat exchanger.

•   As the heat exchanger is supplied indirectly, the producer is not acquainted with its actual 

application. 

•   The heat exchanger should be installed in conformance with the recognized national standards 

of electrical and refrigeration installation practice. 

•   The supplied heat exchanger is optimized for the refrigerants as stated in the data sheet or 

order documents. The allowed maximum pressure is noted on the type plate. During production 

the heat exchanger was subjected to a strength test exceeding the design pressure. However, 

during normal use the design pressure may not be exceeded.

•   Heat exchangers supplied by Alfa LU-VE are normally not equipped with a high-pressure cut 

out. The installer is responsible for fitting a high-pressure cut out on the system in which the 

heat exchanger is used.

•   The heat exchanger shall not be blocked in. If the ambient temperature rises, the pressure could 

rise and exceed the design pressure.

•   It is not permitted to use the heat exchanger for any purpose other than the one it was designed 

for by Alfa LU-VE.

•   If the equipment is used in the food industry, responsibility with regard to hygienic conditions lies 

with the end user.

1.6  Use of flammable gas

•  The product must be stored and installed in rooms where the use of open flames or other  

 

  ignition sources is forbidden

•  During transport, handling, installation, the product and, in particular, the pipes must be  

 

  protected to avoid physical damage which may cause it breakage.

•  In the event of suspicious damages or doubts about the correct handling (eg. damaged  

 

  packaging) do not install the product before carrying out a thorough integrity check.

•  Install the product only and exclusively in places that comply with the minimum size and/or air  

  exchange requirements established by the applicable standards, in relation to the total charge of  

  flammable fluid provided for in the installation in which it is incorporated.

•  All ordinary and extraordinary maintenance operations must be performed only by qualified    

  personnel in the use of equipment with flammable fluid. special attention to operations that    

  require interventions on the pipes.

•  The use of refrigerants different than those indicated in the data plate or in this manual is  

 

 forbidden. 

 

  In general, the use of refrigerants that are not included in the list of the IEC 60335-2-40 Annex b  

  standard is forbidden.

•  Before performing any maintenance operation, exclusively by qualified staff, perform a check for  

  the absence of gas in the room and around the product through an appropriate detector.

•  Before performing any operation for opening the pipes of the refrigerant circuit, by means of    

  mechanical operations or with open flames, make sure that the circuit does not have any  

 

  quantity, even minimal, of inflammable gas and that it has been washed internally with inert    

  gas (ex. nitrogen). all operations must be performed by personnel qualified in the use of  

 

  flammable gases.

•  The product shall not be modified in any part of it, by removing or adding component.s

Содержание ALFA ptigo PF27MC

Страница 1: ...ORIGINAL INSTRUCTIONS 31573808EN 02 Optigo PF27MC Instruction manual Product description Product labels Unpacking lifting Installation Maintenance Spare parts ...

Страница 2: ...d configuration 6 2 3 Options 6 2 4 Code description 6 3 Product labels 7 4 Transport and storage 8 5 Unpacking and lifting 9 6 Installation 11 6 1 Mounting dimensions 11 6 2 Mounting bracket 12 6 3 Technical spaces 12 6 4 Refrigerant connections 13 6 5 Cooler capacity check 14 6 6 Drain line 14 6 7 Electrical connections 15 6 8 Power failure 15 6 9 Fan motors connections 16 6 10 Defrost 16 7 Main...

Страница 3: ...find product information Detailed technical data for individual product models are available in order related documents on the product label and in product data sheets Comprehensive technical information for all Alfa LU VE air heat exchanger products is available on line on alfa luvegroup com This includes Product manuals Instruction manuals Product leaflets brochures Product data sheets selection...

Страница 4: ...y responsibility with regard to hygienic conditions lies with the end user 1 6 Use of flammable gas The product must be stored and installed in rooms where the use of open flames or other ignition sources is forbidden During transport handling installation the product and in particular the pipes must be protected to avoid physical damage which may cause it breakage In the event of suspicious damag...

Страница 5: ...e must be reported on the delivery note with a description of the damage Damaged heat exchangers including when the damage is not externally visible are to be reported to the shipping agent and Alfa LU VE within 24 hours 1 8 Return of unused heat exchangers Air heat exchangers that have been delivered in accordance with orders are in principle not returnable Heat exchangers can only be returned un...

Страница 6: ...e with 1 to 4 fans fitted with high efficiency single speed Ø 275 mm EC fan motors drawing through the coil Power supply 230 50 1 Fan motors are wired to a central connection box Durable galvanized steel casing powder coated RAL 9003 Dismountable and openable casing for cleaning and inspecting purposes Each heat exchanger is leak tested with dry air and finally supplied with a dry air pre charge D...

Страница 7: ...s 40 C 55 C Max Pres 2 4 MPa VENTILATION Nr Motors 2 PowerS 230 V 50 Hz 180 W 0 8 A N N MADE IN POLAND DEFROSTING E X A M P L E E X A M P L E 2 Product label This label is positioned inside the casing Model Refer to paragraph 2 4 Code description Product code Product Serial nr Communicate these when ordering spare parts as they identify the unit PED Category According to PED Fluid Refrigerant Volu...

Страница 8: ...may cause damage to the product If required consult Alfa LU VE and disassemble during transport any parts that are likely to be set into vibration Air heat exchangers must be adequately fixed on the transport vehicle If temporary storage of the heat exchanger is required the following points should be observed Store the heat exchanger in its packing in a dry place with sufficient protection agains...

Страница 9: ... from the original support pallet now on top and remove it The cooler is now in mounting position PF27MC models are delivered on a wooden pallet covered with a reinforced cardboard box Handling and positioning can take place manually smaller models or with use of a forklift 5 Unpacking and lifting In order to avoid damage to the air cooler or falling of the unit ensure that the lifting forks cover...

Страница 10: ...ing secured the cooler the forks may be lowered and the remaining packaging materials can be removed Ensure that the cooler is not lifted directly onto the drip tray or the finned coil Utilizing the proper wooden transport beams and or pallets prevents the cooler bending at the extremes such that the cooling circuit or other components are damaged All lifting procedures must be carefully carried o...

Страница 11: ...nstall in a location too close to heat sources that may increase the vibration of the unit that cannot support the weight of the unit subject to risk of exposure to combustible gas exposed to oils and vapours with unusual environmental conditions Choose a location where the noise and exhaust air are within the limits permitted by applicable standards and regulations protected from headwinds with t...

Страница 12: ...restrictions Recirculation of air is to be avoided The heat exchangers should not be connected to ducting on either the air inlet side or discharge side unless the heat exchanger has been specifically designed for such an application It is important to remember that the total amount of heat to be dissipated depends on receiving the full design air volume at the design entry air temperature which a...

Страница 13: ...to the pipework All pipework should be adequately attached to the walls ceilings of the cold room and not only to the cooler itself Pipework must be adequately supported to prevent vibration or external load on the cooler headers etc Components that may cause gas leaks for example pressure points must not be installed inside the product All refrigeration connections must be made by brazing Do not ...

Страница 14: ...itted must be correctly sized for the installation conditions and adjusted for correct system operation Connect the drain tubing F to the drain connection G All pipework should be adequately attached to the walls ceilings of the cold room and not only to the cooler itself 6 6 Drain line Check all drain lines and driptray to ensure that no improper material such as e g packaging material blocks the...

Страница 15: ...by the manufacturer The following data determine which connection diagram is to be selected and respected for electrical installation Heat exchanger model indication Fan motor type Electrical options When in doubt always contact your local supplier or Alfa LU VE representative for assistance Ensure complete electrical isolation before performing any wiring In accordance with the current legislatio...

Страница 16: ...tral wire it must be connected if indicated in the electrical scheme It must not be connected if it is not shown in the electrical scheme Coolers without defrosting facilities may not be used in room temperatures below 2 C If the cooler is working on a time termination cycle it is suggested that an initial defrost period be set at 35 to 45 minutes in combination with the number of defrost periods ...

Страница 17: ...ectrical isolation before performing any wiring n of fans Electric defrost in coil and driptray heater E E E HD n W x1 W tot W tot 1 4 250 1000 1200 2 4 450 1800 2150 3 4 650 2600 3080 4 4 800 3200 3850 available only for 7 mm fin spacing units n of fans Driptray heater HD n W 1 1 200 2 1 350 3 1 480 4 1 650 3 N 400V 50 60Hz E E E E E HD HD STANDARD N L3 L2 L1 PE L3 L2 L1 N N PE ...

Страница 18: ...able Moisture can cause malfunctioning in the refrigeration operation A lesser known problem is that small amounts of moisture in the refrigeration system can after a time cause leakage through the formation of frost clumps These frost clumps are the result of moisture seeping from the refrigeration system during defrost as water seeps into the soldering seams and then freezes resulting in a volum...

Страница 19: ...e heaters are at ambient temperature 1 2 HD E 4 3 1 2 5 U 6 E U V To remove electric defrost elements E open the driptray and side covers on both sides Disconnect heater element from connection box On the opposite cooler side remove fixing clip U and extract element from coil 3 3 7 8 10 10 9 U U 3 12 12 11 new new Mount new element in reverse order and reassamble the fixing clip in the correct pos...

Страница 20: ...elements replacement Before handling heater elements always disconnect power supply ensure heaters are at ambient temperature To remove driptray heater elements HD open the driptray Z HD 1 2 HD E Disconnect heater element and remove element from bottom plate while gently bending the fixing clips Z Mount new element in reverse order Close driptray and restore electrical connections ...

Страница 21: ...lso be checked for any erosion or corrosion and remedial action taken as necessary All dirt and other contamination should be removed to avoid imbalanced running of the fan and motor bearing overheating The security of the fan fastenings and the integrity of the components should be checked integrally as part of the routine maintenance operation Particular attention should be paid to the fastening...

Страница 22: ...hot Use reliable protection Working fluids Working fluids might be toxic and or flammable These substances may only be handled by qualified staff while taking all necessary precautions and following any applicable regulations Fan vibrations Continuous fan vibrations can cause material failure and hence a risk of injury or damage due to loose parts Therefore vibrations must be reduced to a minimum ...

Страница 23: ...s the right to change specifications without prior notification Spare parts Optigo PF27MC 1 Electric defrost E only for 7 mm fin spacing 2 Fan motor 3 Impeller 4 Fan grid 5 Driptray heater HD 6 Driptray Contact your local Alfa LU VE representative for spare parts order and assistance 10 Spare parts ...

Страница 24: ...alfa luvegroup com ...

Отзывы: