XGB Analog edition manual
13.4 Characteristic of I/O Conversion
Voltage/Current input ranges are able to set from each channel by using user program or I/O
parameter. Data output type of digital is defined as below.
(1) Unsigned Value
(2) Signed Value
(3) Precise Value
(4) Percentile Value
Digital
output
value
0
4000
8000
12000
16000
16191
-192
-8000
-4000
0
4000
8000
8191
-8192
0
2500
5000
7500
10000
10119
-120
DC 1 ~ 5 V
DC 0 ~ 5 V
DC 0 ~ 10 V
DC 4 ~ 20 mA
1 V
5 V
3 V
0 V
2.5 V
5 V
0 V
5 V
10 V
4 mA
12 mA
20 mA
Analog
input
value
Analog input applicable
range
Offset
value
Gain
value
DC 0 ~ 20 mA
0 mA
10 mA
20 mA
DC -10 ~ 10 V
-10 V
0 V
10 V
(1) DC 4 ~ 20mA Input range
Digital
output range
Analog input current (
㎃
)
3.808
4
8
12
16
20
20.191
Unsigned value
(-192 ~ 16191)
-192
0
4,000
8,000
12,000
16,000
16,191
Signed value
(-8192 ~ 8191)
-8,192
-8,000
-4,000
0
4,000
8,000
8,191
Precise value
(3808 ~ 20191)
3,808
4,000
8,000
12,000
16,000
20,000
20,191
Percentile value
(-120 ~ 10119)
-120
0
2,500
5,000
7,500
10,000
10,119
(2) DC 0 ~ 20mA Input range
Digital
output range
Analog input current (
㎃
)
-0.24
0
5
10
15
20
20.239
Unsigned value
(-192 ~ 16191)
-192
0
4,000
8,000
12,000
16,000
16,191
Signed value
(-8192 ~ 8191)
-8,192
-8,000
-4,000
0
4,000
8,000
8,191
Precise value
(-240 ~ 20239)
-240
0
5,000
10,000
15,000
20,000
20,239
Percentile value
(-120 ~ 10119)
-120
0
2,500
5,000
7,500
10,000
10,119
13 - 6
Содержание XGB Series
Страница 70: ...XGB Analog edition manual 2 36 Program in case of IEC type ...
Страница 72: ...XGB Analog edition manual 2 38 ...
Страница 73: ...Chapter 2 Analog Input Module XBF AD04A 2 39 Program in case of IEC type ...
Страница 134: ...Chapter 4 RTD Input Module XBF RD04A XBF RD01A 4 Program example using PUT GET function block inn case of IEC 4 27 ...
Страница 340: ...XGB Analog edition manual e Select View Variable Comments Variable and comment both are displayed 9 20 ...
Страница 491: ...XGB Analog edition manual 4 Click Yes 5 As shown below the variables are registered 13 30 ...
Страница 494: ...Chapter 13 Analog Input Module XBF AD04C 4 Select View Device Comments Devices and comments are both displayed 13 33 ...
Страница 495: ...XGB Analog edition manual 5 Select View Variables Comments Variables and comments are both displayed 13 34 ...
Страница 546: ...XGB Analog edition manual 4 Program example using PUT GET instruction in case of IEC type 14 38 ...
Страница 581: ...XGB Analog edition manual 15 32 In case of IEC type APM_WRT funcion block is used ...
Страница 597: ...XGB Analog edition manual 15 48 d In case of IEC type example program In case of IEC type the following program is used ...
Страница 607: ...Appendix 2 Thermo electromotive force and compensating force Appendix 2 2 Type T Type R unit unit ...
Страница 611: ...Appendix 3 Appendix 3 1 Appendix 3 Dimension 1 Dimension of XBF AD04A Unit mm 2 Dimension of XBF DV04A DV04C Unit mm ...
Страница 613: ...Appendix 3 Appendix 3 3 5 Dimension of XBF TC04S Unit mm 6 Dimension of XBF AH04A Unit mm V I XBF AH04A ...
Страница 614: ...Appendix 3 Appendix 3 4 7 Dimension of XBF AD08A Unit mm 8 Dimension of XBO AD02A Unit mm ...
Страница 615: ...Appendix 3 Appendix 3 5 9 Dimension of XBO DA02A Unit mm 10 Dimension of XBO AH02A Unit mm ...
Страница 616: ...Appendix 3 Appendix 3 6 11 Dimension of XBO RD01A Unit mm 12 Dimension of XBO TC02A Unit mm ...