XGB Analog edition manual
2 - 6
2.5 Conversion Characteristic according to Input Range
Voltage input range can be set through user program or special module package for respective
channels. Output formats of digital data are as specified below;
A.
Unsigned
Value
B. Signed Value
C. Precise Value
D.
Percentile
Value
2.5.1 If the range is DC 0 ~ 10V
Digital output value for voltage input characteristic is as specified below.
(Resolution (based on 1/4000): 2.5 mV)
Digital output
range
Analog input voltage (V)
0
2.5
5
7.5
10
10.11
Unsigned value
(0 ~ 4047)
0 1000 2000 3000 4000 4047
Signed value
(-2000 ~ 2047)
-2000 -1000 0 1000 2000 2047
Precise value
(0 ~ 1011)
0 250 500 750
1000
1011
Percentile value
(0 ~ 1011)
0 250 500 750
1000
1011
Содержание XGB Series
Страница 70: ...XGB Analog edition manual 2 36 Program in case of IEC type ...
Страница 72: ...XGB Analog edition manual 2 38 ...
Страница 73: ...Chapter 2 Analog Input Module XBF AD04A 2 39 Program in case of IEC type ...
Страница 134: ...Chapter 4 RTD Input Module XBF RD04A XBF RD01A 4 Program example using PUT GET function block inn case of IEC 4 27 ...
Страница 340: ...XGB Analog edition manual e Select View Variable Comments Variable and comment both are displayed 9 20 ...
Страница 491: ...XGB Analog edition manual 4 Click Yes 5 As shown below the variables are registered 13 30 ...
Страница 494: ...Chapter 13 Analog Input Module XBF AD04C 4 Select View Device Comments Devices and comments are both displayed 13 33 ...
Страница 495: ...XGB Analog edition manual 5 Select View Variables Comments Variables and comments are both displayed 13 34 ...
Страница 546: ...XGB Analog edition manual 4 Program example using PUT GET instruction in case of IEC type 14 38 ...
Страница 581: ...XGB Analog edition manual 15 32 In case of IEC type APM_WRT funcion block is used ...
Страница 597: ...XGB Analog edition manual 15 48 d In case of IEC type example program In case of IEC type the following program is used ...
Страница 607: ...Appendix 2 Thermo electromotive force and compensating force Appendix 2 2 Type T Type R unit unit ...
Страница 611: ...Appendix 3 Appendix 3 1 Appendix 3 Dimension 1 Dimension of XBF AD04A Unit mm 2 Dimension of XBF DV04A DV04C Unit mm ...
Страница 613: ...Appendix 3 Appendix 3 3 5 Dimension of XBF TC04S Unit mm 6 Dimension of XBF AH04A Unit mm V I XBF AH04A ...
Страница 614: ...Appendix 3 Appendix 3 4 7 Dimension of XBF AD08A Unit mm 8 Dimension of XBO AD02A Unit mm ...
Страница 615: ...Appendix 3 Appendix 3 5 9 Dimension of XBO DA02A Unit mm 10 Dimension of XBO AH02A Unit mm ...
Страница 616: ...Appendix 3 Appendix 3 6 11 Dimension of XBO RD01A Unit mm 12 Dimension of XBO TC02A Unit mm ...