T9601 Quick Programming Functions Guide
When programming functions:
1.Press PROG
2. Enter the Function Code
3. Press ENT
* Make sure POCSAG Start is set
Long Range Systems
19
T9601 User Manual
Function
Function
Code
Notes
Reset
0
System settings default to:
Station ID = 1
System ID = 0
Vibration 1, 2, or 3
9 2 #
# = Vibration = 1, 2, or 3
POCSAG Start
8 # #
## = Start = 01 – 99
System ID (Restaurant ID)
9 ##
## = ID = 00 – 19
Time: Send to Pager
9 3 1
Sends Time and Date to Alpha Pagers
Set Time
9 3 2
At
TIM
enter hh mm (Hour, Minute) Press ENT
Press A or P (AM/PM)
Set Date
9 3 3
At
DTE
enter mm (Month), press ENT
dd (Day), press ENT
yy (Year), press ENT
Setup All Call
9 3 #
# = 4= ON # = 5 = OFF
Vibration Strength
9 4 #
(# = 1 – 9) # = 0 = OFF
# = 1 = Minimum # = 9 = Maximum
Simultaneous Manager Paging
9 5 #
# = 1 = ON # = 2 = OFF
Language
9 5 #
# = Language
• English = 3
• Spanish = 4 • French = 5
• German = 6 • Italian = 7
• Portuguese = 8
Station ID
9 6 #
# = ID = 1 – 9
Firmware Version
9 7 5
Duty Pager Setup
9 8 0
At dut , enter pager #, and press ENT(Pager # = 0 disables)
At Int, enter interval time and press ENT
At Str, enter start time and press ENT
At Stp, enter stop time and press ENT
Duty pager Reset
9 8 1
Restarts interval timer on duty pager
Manager Pager
9 8 5
At
Mgr
, enter the pager number
Press ENT
Enable/Disable Key Tone Beep
9 8 #
# = 6 = ON # = 7 = OFF
Enable/Disable AM paging
9 9 #
# = 1 = ON # = 0 = OFF
Range Test
9 9 7
Enables Range Test (Press ENT to stop)
POCSAG anti theft ON/OFF
9 9 #
# = 9 = ON # = 8 = OFF
All Call Paging
Press PGR Enter “0” and Press ENT
One Touch Paging
Press the
pager # Pager #’s (1 – 16)
High Number Paging
Press PGR Enter pager # (1-999) and Press ENT
*Programming Pagers
Press PROGEnter pager # (1-999) and Press PROG