background image

Installation, Warranty and Service Information

Long Range Systems, Inc.

4550 Excel Parkway, Suite 200 

Addison, TX 75001

800.437.4996 

www.pager.net

T9100 &
Cancel Panel

Paging System Transmitter

U S E R   M A N U A L

Содержание Cancel Panel

Страница 1: ...Installation Warranty and Service Information Long Range Systems Inc 4550 Excel Parkway Suite 200 Addison TX 75001 800 437 4996 www pager net T9100 Cancel Panel Paging System Transmitter USER MANUAL ...

Страница 2: ...te 9 Paging 9 Cancel Page 9 User Preferences 10 Display Current Settings 10 Antitheft 10 Display Clock 11 Vibe Level 11 Keytone 11 Preset Message 12 Repaging 13 Repeater Delay 13 Duty Pager 13 Restaurant ID 13 Station ID 14 POCSAG FM Start 14 Edit Manager Pager Number 14 Reset to Factory Default 14 Server Statistics 14 Range Test 16 Find ID 16 Three Digit POCSAG Paging 16 Pager Programming 17 Long...

Страница 3: ...s 2 4 GHz Master 21 Service Questions and Answers 22 LRS PAGERS AVAILABLE FOR THE T9100 23 USING THE SP5 23 Charging 23 Menus 23 Settings 25 Messages 25 Time 25 Reprogramming and Reset 25 USING THE LRS ALPHA E467 26 Menus 26 Power On Off 26 Read Message 27 Delete Messages 27 Time Date Set 27 Set Contrast 27 Auto ON OFF 27 Set Keytone On Off 27 Select Alert 28 USING THE STAR PAGER 29 Charging 29 Me...

Страница 4: ...he antenna about 4 long SMA bends at right angle onto the gold connector Note Both antennas must be attached before turning on transmitter Do not remove either an tenna at any time due to risk of damage 4 Mount the power supply in convenient location with access to 110V power Mounting the Transmitter The T9100 is designed to be mounted in various ways to accommodate the kitchen environment to a ho...

Страница 5: ...ntal surfaces and one set of captive nuts for mounting to vertical surfaces To attach the clamps 1 Align the mounting nuts to the clamps 2 Use the 10 32 x 3 8 screws to hold the clamps Do not fully tighten screws 3 Adjust the distance between clamps until fits to the mounting surface 4 Tighten screws Long Range Systems 4 T9100 User Manual Captive Nuts Clamp Captive Nuts Screws ...

Страница 6: ...lace Because the thumbscrews and brackets can be mounted in many ways they can be adapted to most locations is possible Horizontal Mount Vertical Mount Long Range Systems 5 T9100 User Manual Clamp with Foam Pad Thumbscrew Foot Thumbscrew Turn clockwise to tighten Turn counter clockwise to loosen Thumbscrew Mounting Bracket Mounting Screws Thumbscrew Mounting Bracket Mounting Screws ...

Страница 7: ...100 User Manual Power Connection 1 Plug the power supply into a standard 110V outlet and the barrel connector end into the jack on the side of the transmitter 2 Upon completion of the setup make sure pagers are fully charged ...

Страница 8: ... Vibration Keys V1 V2 and V3 select the number of vibrations a pager will respond with This button is pressed before pag ing a pager Sends message 1 2 or 3 to Alpha pagers Number Keys Number keys 1 through 10 located along the center row Number 10 is also 0 when Programming using the Menus or paging pagers greater than 10 1 2 3 4 5 6 7 8 9 10 M1 M2 86 CLR PROG ENT V1 V2 V3 www pager net 0 CANCEL P...

Страница 9: ...Cancel Panel Reset Terminals The Reset Terminals are located to the user s left side on the transmitter These are used to reset a pager for programming Status LED This LED will light green to indicate that the T9100 is sending information to the pagers or T9100 Cancel Panel System Specifications Notice Operation is subject to the following This device may not cause interference This device will ac...

Страница 10: ...Yes after 30 seconds of inactivity Send Time This feature will automatically send the current time and date to the pagers every 15 minutes The default setting is OFF To enable Press PROG PROG 1 ENT Press button under Send At Auto select button under ON If done select Yes button under Yes if not select No button under No To disable Press PROG PROG 1 ENT Press button under Send At Auto Press select ...

Страница 11: ...en on Cancel Panel UHF Master T9100 is set to Master yes or no Node ID Pan and Channel ID Channel Scan is on or off Synched on or off Beeper keytone is on or off Code Version Error Count If done press 6 for Yes if not press 10 for No Antitheft Note This feature is ONLY for text pagers This feature will make a pager beep and or vibrate continuously if goes beyond the range of the transmitter To ena...

Страница 12: ... select No button under No Vibe Level The default Vibration Level for pagers can be set via 1 Pressing the V1 V2 or V3 buttons for levels 1 2 and 3 respectively 2 From the menus Press PROG PROG 1 2 ENT Enter a value of 1 2 or 3 from the keypad If done select Yes button under Yes if not select No button under No Keytone The transmitter default is for tones to sound with each key press To disable Pr...

Страница 13: ...Phone Call 001 Sales Call 002 Manager 003 Customer 004 Room 005 Visitor 006 call Ext 007 MTG Room 008 Lane 009 Aisle 010 Void 011 Stamps 012 Change 013 Station 014 Machine 015 Operator 016 Emergency 017 XX Minutes 018 Tee 019 Pro Shop 020 Starter 021 Service drive 022 Showroom 023 Parked Call 024 Voice Mail 025 Dressing room 026 Price check 027 Department 028 Cashier 029 Office 030 Table 031 Winne...

Страница 14: ...Press button under More Press button under repeater At rPt press button under ON to enable the Repeat Delay Press button under OFF to disable Repeat Delay If done select Yes button under Yes if not select No button under No Duty Pager The duty pager is used to remind someone of a periodic repetitive task To setup Press PROG PROG 7 ENT At duty press button under On After 10 seconds the screen will ...

Страница 15: ...on under Yes if not select No button under No Reset to Factory Default Note Caution If you reset the T9100 to factory defaults the system ID vibration mode and sta tion ID could be reset and you may have to re set these to work with your exist ing pagers If you still want to proceed with this function do the following Press PROG PROG 2 1 ENT At reset press button under Yes Select No to keep curren...

Страница 16: ... line to correct the connection To print a current view of the Server Statistics Press PROG PROG 2 4 ENT Enter a server number and press ENT Press button under PRINT The statistics will now print If done select Yes button under Yes if not select No button under No Note The Statistics will also print at the time set in the Stats menu Example Print Viewing Statistics To View the current Server Stati...

Страница 17: ...omatically increment to the next ID and page Repeat this step until the pager receives the page If done select Yes button under Yes if not select No button under No Three Digit POCSAG Paging If using the T9100 in an LRS system with Group Programmed POCSAG Pagers the Group Paging mode will allow the T9100 to page the three digit individual pager number of the POCSAG Pager When this mode is turned o...

Страница 18: ... Rechargeable pagers are removed from the charger or touched to the reset terminals They stop vibrating when reset is complete Battery powered pagers reset when turned off and then back on or remove and replace battery 4 Press PROG ENT is the pager number 1 through 99 5 After the pager responds page it to ensure it programmed okay Star pagers will do one glow mode cycle Alpha pagers will beep 4 ti...

Страница 19: ... Vibration Keys V1 V2 and V3 select the number of vibrations a pager will respond with This button is pressed before pag ing a pager Sends message 1 2 or 3 to Alpha pagers Cancel Keys The row of keys located below the display These keys will cancel a call to the pager number shown on the display immediately above the respective key The Cancel Keys also are used during menu selection 1 2 3 4 5 6 7 ...

Страница 20: ...splay If not canceled the pager number will begin to flash after the first re page time expires The pager number will flash faster after the second re page time expires Cancel Page To Cancel a page press the Cancel Key immediately under the number of the pager If using a Cancel Panel with T9100 the pager number may be canceled from the Cancel Panel or by press ing CLR then the pager number on the ...

Страница 21: ...ng from Cancel Panel This feature enables or disables the Cancel Panel from paging pagers This feature is only available and only set on the Cancel Panel The default setting is On to page pagers To disable Press PROG PROG 1 7 At CP Paging press the cancel button under OFF If done select Yes button under Yes if not select No button under No To enable Press PROG PROG 1 7 ENT At CP Paging press the c...

Страница 22: ...ny T9101 T9100 or T9100 can act as a single coordinater for the 2 4 GHz network synchronizing most set tings and clocks for all transmitters To Set a Transmitter as Master 1 Press PROG PROG 25 T9101 or PROG PROG 2 5 T9100 CP 2 Select YES 3 The transmitter will now restart and display the time and date entry Enter the time and date If another transmitter in the network does not successfully change ...

Страница 23: ...call Long Range Systems at 800 437 4996 Normal Business Hours Monday Friday 8 30 am to 5 00 pm Central Time Weekend or Night Emergencies Long Range Systems has 24 7 live technical support available Please keep in mind that replacement options are limited over the weekend Long Range Systems 22 T9100 User Manual ...

Страница 24: ...n the pager to the charger at the end of each day Menus To access the vibe contrast menu simply remove the pager from the charger or use the reset terminal on the T9100 While it is vibrating or beeping press and hold the Select Button for 8 seconds The following top level menu will display If you PRESS and RELEASE the Select Button the menu selector will scroll to the right and will high light Con...

Страница 25: ...Contrast To set the Contrast Level 1 Remove the pager from the charger 2 While vibrating or beeping press and hold the Select Button for 5 8 seconds 3 Highlight the Contrast selection then PRESS and HOLD the Select Button until the screen shows 4 Press or hold the Select Button until the desired contrast is selected 5 If holding down on the Select Button the contrast level will increase to Max NOT...

Страница 26: ...ages To view the messages 1 At the blank screen time date menu display press the Select Button once 2 Messages 2 lines in length will show a symbol at the end of the first line and a symbol at the be ginning of the second line 3 Messages over 2 lines in length the middle lines will show the next line of the message 4 Press the Select Button to continue scrolling forward through the message or mess...

Страница 27: ...et Power On Off Set ON if unit is off 1 Press and hold Scroll Up until YES NO shows 2 At Power ON use Up or Down Scroll button to select YES 3 Press Read Select button to set Set OFF 1 Using the Up or Dn scroll button scroll until display shows Power OFF 2 Press Read Select button to set power on off 3 At Power OFF screen use Up or Down Scroll button to select YES 4 Press Read Select button to set...

Страница 28: ...ress Read Select to move through the segments Set Contrast 1 Using the Up or Down scroll button scroll until display shows Set Contrast 2 Press Read Select 3 Use the Up or Down scroll button to adjust 4 Press Read Select to confirm Auto ON OFF 1 Using the Up or Down scroll button scroll until display shows Auto ON OFF 2 Press Read Select to set auto on off 3 Use the Up or Down scroll button to sel...

Страница 29: ...Alert Mode 2 Use the Up or Down scroll button to select Beep Vibe Off 3 Press Read Select to set Beep Use the Up orDown scroll button to select Select Loud or Soft and press Read Select to set Select Duration seconds and press Read Select to set Vibe Off Use the Up or Down scroll button to select Press Read Select to set ...

Страница 30: ...sing the V1 V2 or V3 button This can be a way to send ad ditional information or to identify 1 of 3 stations On the front of the pager are four lights 1 through 4 In normal operation each station or T9100 would be set for different STATION ID s e g kitchen is station 1 etc Each station will also send different messages example 1st light for station 1 2nd light for station 2 4th and 1st light for s...

Страница 31: ...s Pagers and equipment that are cleaned with unapproved clean ers and suffer cracking will not be covered under warranty Do not submerge any LRS paging equipment in any type of liquid as this will also dam age the equipment and is not covered under the standard warranty Charging Place rechargeable pagers on the charger and let them charge for 8 hours prior to first use Rechargeable pagers should b...

Страница 32: ...f business resulting from inaccuracies or omissions Specifications and other information contained within this document are subject to change without notice Long Range Systems Inc reserves the right to make changes without further notice to any products herein LRS Inc makes no warranty representation or guarantee regarding the suitability of its products for any particular purpose nor does LRS Inc...

Отзывы: