ENGLISH
ENGLISH
14
09.
TROUBLESHOOTING
PROBLEM
ORIGIN
SOLUTION
1. The softener
does not perform
regeneration.
2. Hard water.
3. High
consumption of
salt.
4. Drop of resins
through the drain
or service outlet.
5. Loss of resins
through the drain
or service outlet.
Check the electrical installation.
Failure in the electric connection.
Replace the programmer. Contact TS.
Faulty programmer.
Reprogram the current time.
Temporal power supply cut.
Check By-pass valve in service position.
Contact TS.
Water meter does not work.
Turn by-pass valve to the SERVICE position
adjusting the mixing to level 1 or 2.
Mixer or by-pass valve open.
Reprogram following instructions. Contact TS.
Incorrect programming of
regeneration cycles.
Check meter. Contact TS.
Water meter does not work.
Reprogram water volume between regenerations.
Check there are no water leaks in the installation.
Excessive water consumption
between regenerations.
Pressure or time insufficient. Adjust according to
the instructions. Contact TS.
Lack of water in the salt tank.
Pressure or tank refill time are too high. Adjust
according to instructions. Contact TS.
Incorrect adjustment of the salt
dose.
Adequate maximum flow to the value indicated
by the installer.
Service flow too high.
Replace or change filter.
Inlet filter saturated.
Increase backwash time. If not solved, contact
TS to clean resin bed.
Resin bed of the softener is
dirty.
Contact installer or TS.
Resin damage due to chlorine
excess.
Contact installer or TS.
Inlet and outlet conductions
are dirty.
Contact with TS.
Note: During the first liters water has a yellow
color due to small fragments of resin.
Crepines or distribution tube
damaged or misadjusted.
Resin damaged due to chlorine
excess.
See anomaly 8.
Excessive amount of water in
the salt deposit.
Verify electrical installation. Program time and do
a manual regeneration.
Power supply cut.
Clear drainage tube.
Blocked tube to drain.
Clean/change filter or injector.
Change valve main body
Contact TS.
Internal leak on valve or
distributor.
Adequate maximum flow to the value indicated
by the installer.
Excessive service flow.
Add salt and maintain its level over the water.
Lack of salt in the tank.
Содержание TM73 TWIN
Страница 1: ...MANUAL DE USUARIO USER S MANUAL V lvula TWIN TM73 TM73 TWIN valve...
Страница 34: ......