ENGLISH
ENGLISH
11
8. Set third cycle (Brine):
Press the button DOWN to set the third cycle. The screen will show program 3, which is the duration of the
brine
.
Press the “Menu/confirm” for setting the third cycle. With UP and DOWN adjust the time of the brine and
confirm pressing the button “Menu/confirm” (see the table 2). Press the button “Menu/confirm” to confirm.
9. Set the fourth cycle (Brine refill):
Press the button DOWN to set the fourth cycle. The screen will show program 4, which is the duration of the
brine refill
.
Press the “Menu/confirm” for setting the fourth cycle. With UP and DOWN adjust the time of the brine refill
and confirm pressing the button “Menu/confirm” (see the table 2). Press the button “Menu/confirm” to con-
firm.
10. Maximum days between regenerations H- :
Press the button DOWN, the screen will show H- (maximum days between regenerations).
These are number of days that if there is no water consumption after the days we have scheduled, there will
be a maintenance regeneration.
Press “Menu/confirm” and use UP and DOWN to set the number of days you wish, between 00 and 40. That
is preset at 30 days. Press “Menu/confirm” to confirm.
Resine quantity (liters) and Cycle times
20
30
40
50
75
100
7 min
8 min
10 min
12 min
15 min
14 min
Resine
liters
Bottle
1st cycle
Quick wash
Program 1
2 min
3 min
4 min
10 min
6 min
5 min
2nd cycle
Backwash
Program 2
43 min
41 min
54 min
57 min
66 min
74 min
3rd cycle
Brine
Program 3
2 min
2 min
3 min
4 min
4 min
5 min
4th cycle
Brine refill
Program 4
8x35
10x35
10x44
12x48
12x48
13x54
Injector
Yellow
White
White
Black
Black
Purple
Table 2. Regeneration time for each cycle (using standard resine as reference) at 3 bars entry pressure.
11. External signal mode:
Finally, pressing DOWN, the screen will show
b-01 (external signal mode)
.
This option has two choice:
b-01: For connect an additional pump or electrovalve. Useful in installations with insufficient pressure or
with external by-pass management (it requires additionals components).
b-02: For connect an additional electrovalve to despresurize during the placement of the ceramics discs.
Useful in big equipments and high pressures. It requires additionals components.
Содержание TM73 TWIN
Страница 1: ...MANUAL DE USUARIO USER S MANUAL V lvula TWIN TM73 TM73 TWIN valve...
Страница 34: ......