ENGLISH
ENGLISH
10
Set for intelligent programmation (options A-03, A-13)
Liters of resin:
Press DOWN appears on the screen, adjust 50L of resin we have in the bottle.
To adjust, press “Menu/confirm” and change with the UP and DOWN buttons until the desired value. Press
“Menu/confirm” to confirm.
Hardness of the main water:
Press the button DOWN, the screen will show Yd-1,2. You must set the mains water hardness in milimoles.
10 french degress = 1 milimol.
To adjust, press “Menu/confirm” and change the value with UP and DOWN until the desired value. Press
“Menu/confirm” to confirm.
Interchangeability:
Press DOWN. The screen will show AL-0,65. This is the resin exchange capacity. Set it at 0,55.
To adjust, press “Menu/confirm” and change the value with UP and DOWN until the desired value. Press
“Menu/confirm” to confirm.
Regeneration: adjustment of cycle times:
TWIN valve follows the special criteria for the order of the regeneration cycles. In each regeneration, the first
thing that will take place will be the quick wash in the bottle is not in service. Made the quick wash, the same
bottle will enter service while the other starts with the regeneration cycles (backwash, brine suction, brine
charge). Note that the rapid wash is always held just before the bottle is put in service.
Quick wash, which is made when the service is consumed bottle to descale the m
3
is pending in the reclai-
med bottle.
- U1: It is the bottle where the valve is mounted.
- U2: It is the additional bottle
6. Set the first cycle (quick wash):
Press the button DOWN to set the first cycle. The screen will show program 1, which is the duration of the
quick wash
.
Press the “Menu/confirm” for setting the first cycle. With UP and DOWN adjust the time of the quick wash
and confirm pressing the button “Menu/confirm” (see the table 2). Press the button “Menu/confirm to
confirm.
7. Set the second cycle (brine):
From the previous state, press the DOWN button until the display shows program 2, which is the
backwash
duration (in minutes).
Press the ”Menu/confirm” for setting the second cycle. With UP and DOWN adjust the time of the backwash
and confirm pressing the button “Menu/confirm” (see the table 2). Press the button “Menu/confirm” to
confirm.
Содержание TM73 TWIN
Страница 1: ...MANUAL DE USUARIO USER S MANUAL V lvula TWIN TM73 TM73 TWIN valve...
Страница 34: ......