I063 I GB 06 08

8

TYPE

R1D

R2D

R3D

R4D

RM1...

RM...

RMT

...

RC...

DESCRIPTION

Flush mount with

Flush mount with transpar

ent 

cover

Flush mount with transparent 

cover

Modular with transpar

ent cove

Modular with t

ransparent cove

Modular with transparent cover

Compact

transparent cover

2 operating thresholds

2 operating thresholds - permanent

1 operating threshold

1 operating threshold

1 operating threshold

1 operating threshold

1 operating threshold

permanent control of toroid-relay coupling

control of toroid-relay coupling

CONTROL

CIRCUIT

To

roidal transformer

External

External

External

External

External

External

Incorporated Ø 28

mm

Incorporated

35-60-80-110 mm

standard diameter

Adjustments

Tripping set-point (I

)

0.025-0.25A (x0.1)

0

.025-0.25A (x0.1)

0.025-0.25A (x0.1)

0.03÷0.3A (x0.1)

0.3A o 0.5A

0.025÷0.25A (x0.1)

0.025÷0.25A (x0.1)

0.025÷0.2

5A (x0.1)

0.25-2.5A (x1)

0.25-2.5A (x1)

0.25-2.5A (x1)

0.3÷3A (x1)

setting via

0.25÷2.5A (x1)

0.25÷2.5A (x1)

0.25÷2.5A (x1)

2.5-25A (x10)

2.5-25A (x10)

2.5-25A (x10)

3÷30A (x10)

dip-switch

2.5÷25A (x10)

2.5÷25A (x10)

2.5÷25A (x10)

25-250A (external multiplier)

25-250A (external multiplier)

25-250A (external multiplier)

30÷300A (external multiplier)

25÷250A (ex

ternal multiplier)

25÷250A (external multiplier)

25÷250A (external multiplier)

Alarm advance set-point

––

70% I

n (fixed)

70% I

n (fixed)

70% I

n (fisso)

––

––

––

––

Tripping time (t)

0.02-0.5s (tx1)

0.02-0.5s (tx1)

0.02-0.5s (tx1)

0.03÷0.5s (tx1)

0.02s o 0.5s setting

0.02÷0.5s (tx1)

0.02÷0.5s (tx1)

0.02÷0.5s (tx1)

0.2-5s (tx10)

0.2-5s (tx10)

0.2-5s (tx10)

0.3÷5s (tx10)

via dip-switch

0.2÷5s (tx10)

0.2÷5s (tx10)

0.2÷5s (tx10)

Selection of multiplier for I

and t

By dip switches

By dip switches

By dip switches

By dip switches

––

By dip switches

By dip switches

By dip switches

Resetting

Automatic or manual

Automatic by remmote contact closing

Automatic by remote contact 

A: Automatic

A: Automatic

A: Automatic

AUTO: Automatic

by button on front

Manual by button on front or remote contact closing

closing. Manual by button on

M: manual by button on front

M: manual by button on front

M: manual by button on front

MAN: m

anual by button on front

front or remote contact closing

Shunt tripping cntrol

––

––

––

Y

es

AUXILIAR

Y SUPPL

Y

Auxiliar

y voltage (Us)

24/48V

AC/DC

24/48V

AC/DC

24-/48V

AC/DC

(0.85 - 1.1 Us)

110÷125V

AC/DC

110÷125/220÷240/380÷415V

AC

110-125/220-240/380-415V

AC

110-125V

AC/DC

220÷240/380÷415V

AC

220-240/380-415V

A

C

Rated frequency

50-60Hz

50-60Hz

50-60Hz

50/60Hz

50/60Hz

Maximum power consumption

5.5V

A

4

.5V

A

4.5V

A

5.5V

A

3V

A

OUTPUT

RELA

YS

State

Normally de-energised

Configurable normally

Configurable normally

Configurable normally

Normally de-energised

Normally de-energ

ised

Configurable normally

Normally de-energised

de-energised or

de-energised or

de-energised or

de-energised or

energised

energised

energised

energised

Contact arrangement

1 changeovers (trip)

2 changeovers (1 trip, 1

alarm)

2 changeovers (1 trip, 1

alarm)

2 changeovers (1 trip, 1 alarm)

1

changeover (trip)

1

changeover (trip)

2 changeovers  (both trip)

1 changeover (trip)

Rated contact capacity Ith

5A - 250V

AC

5A - 250V

AC

5A - 250V

A

C

5A - 250V

AC

5A - 250V

AC

5A - 250V

A

C

5

A - 250V

A

C

5A - 250V

AC

Mechanical life

50

x 10

cycles

50

x 10

cycles

50

x 10

cycles

50x10

6

cycles

50x10

6

cycles

50x10

6

cycles

50x10

6

cycles

50x10

6

cycles

Electrical life

3 x 10

5

cycles

3 x 10

5

cycles

3 x 10

5

cycles

3x10

5

cycles

3x10

5

cycles

3x10

5

cycles

3x10

5

cycles

3x10

5

cycles

INDICA

TIONS

Auxiliaty voltage available (ON)

green LED

green LED

green LED

green LED

green LED

green LED

green LED

green LED

Relay tripping (TRIP)

red LED

red LED

red LED

red LED

red LED

red LED

red LED

red LED

Alarm advance (ALARM)

––

red LED

red LED

red LED

––

––

––

––

Mechanical flag (TRIP)

––

––

Flag indicator

Flag indicator

––

––

––

––

Shunt tripping cir

cuit

––

––

––

red LED

––

––

––

––

INSULA

TION

Insulation test

2.5kV for 1 minute

2.5kV for 1 minute

2.5kV for 1 minute

2.5kV for 1 minute

2.5kV for 1 minute

2.5kV for 1 minute

2.5k

V for 1 minute

2kV for 1 minute

AMBIENT OPERA

TING

CONDITIONS

Operating temperature

-10 to +60°C

-10 to +60°C

-10 to +60°C

-10 to +60°C

-10 to +60°C

-10 to +60°C

-10 to +60°C

-10 to +60°C

Storage temperature

-20 to +80°C

-20 to +80°C

-20 to +80°C

-20 to +80°C

-20 to +80°C

-20 to +80°C

-20 to +80°C

-20 to +80°C

Relative humidity

90%

90%

90%

90%

90%

90%

90%

90%

ENCLOSURE

Material

self-extinguishing

self-extinguishing

self-extinguishing

self-extinguishing polycarbonate

self-extinguishing polycarbonate

polycarbonate

polycarbonate

polycarbonate

Degree of protection

IP20 terminals, 

IP20 terminals,

IP20 terminals,

IP20 terminals,

IP20 terminals, per DIN 40050

IP40 with protective cover

IP40 with protective cover

IP40 with protective cover

IP40 with protective cover

Reference standards

IEC/EN 61010, IEC/EN 61000-6-2,

EC/EN 61000-6-3, IEC/TR 60755

Type A, sensitive to residual sinusoidal AC

and pulsating DC currents.

Содержание R1D

Страница 1: ...tivata Rel ALARM normalmente diseccitato Pulsante TEST Provoca l intervento del rel EARTH LEAKAGE RELAYS R1D R2D R3D R4D Tripping delay time adjustment also see point 3b Fault current to earth adjustm...

Страница 2: ...minali 20 21 22 che normalmente eccitato Il controllo avviene tramite i terminali 17 18 19 che devono essere cos collegati RESET pushbutton To reset the relay after tripping For remote reset of R1D si...

Страница 3: ...avi della linea da controllare inserire le fasi e il neutro se presente Il cavo di terra NON deve attraversare il trasformatore di corrente Versions RM RMT Tripping delay time adjustment also see poin...

Страница 4: ...nx10 constant selection for fault current to earth adjustment The constants in relation to the position of the 2 dip switches are the following dip switch position I nx0 1 and I nx0 1 K 0 1 dip switch...

Страница 5: ...15 4 1 3 5 N L1 L2 L3 Trip 5 4 24VAC DC 5 3 48VAC DC 5 1 380 415VAC 5 3 220 240VAC 5 4 110 125VAC DC RMT Terra GRD Linea Load Carico Load K Bobina di apertura Shunt coil Terra GRD Linea Load Carico Lo...

Страница 6: ...110 70 60 47 60 60 50 RC80 150 160 70 80 70 110 60 50 RC110 150 160 70 110 70 110 60 50 E RC 96 90 66 96 85 16 19 91 91 R3 R4D TIPO A B C D E F G H K RT35 100 110 50 35 47 60 43 30 RT60 100 110 50 60...

Страница 7: ...380 415VAC 110 125VAC DC 220 240 380 415VAC 220 240 380 415VAC Frequenza nominale 50 60Hz 50 60Hz 50 60Hz 50 60Hz 50 60Hz Potenza massima assorbita 5 5VA 4 5VA 4 5VA 5 5VA 3VA REL DI USCITA Stato del...

Страница 8: ...220 240 380 415VAC 110 125VAC DC 220 240 380 415VAC 220 240 380 415VAC Rated frequency 50 60Hz 50 60Hz 50 60Hz 50 60Hz 50 60Hz Maximum power consumption 5 5VA 4 5VA 4 5VA 5 5VA 3VA OUTPUT RELAYS State...

Отзывы: