R1D - R2D - R3D

45

5

67

43

89

52

RM1 - RM

A

H

5

B

E

F

G

C

D

RT35 - RT60 - RT80 - RT110 - RX10

B

A

E

F

5

D

K

G

C

H

RTA110

45

89

5

27

Ø28.5

67

43

105

RMT

B

E

G
C

H

F

A

D

5

E

TIPO

A

B

C

D

E

F

G

H

RC35

100

110

70

35

47

60

60

50

RC60

100

110

70

60

47

60

60

50

RC80

150

160

70

80

70

110

60

50

RC110

150

160

70

110

70

110

60

50

E

RC

96

90

66

96

85

16

19

91

91

R3

R4D

TIPO

A

B

C

D

E

F

G

H

K

RT35

100

110

50

35

47

60

43

30

RT60

100

110

50

60

47

60

43

30

RT80

150

160

50

80

70

110

43

30

RT110

150

160

50

100

70

110

43

30

RT210

310

290

54

210

145

240

280

36

258

RTA110 180

150

45

110

75

110

38

25

145

RTA210 310

290

54

210

145

240

280

36

258

RX10

100

110

50

60

43

30

—     

A

E

5

A

F

B

G

K

D

RT210 - RTA210

Содержание R1D

Страница 1: ...tivata Rel ALARM normalmente diseccitato Pulsante TEST Provoca l intervento del rel EARTH LEAKAGE RELAYS R1D R2D R3D R4D Tripping delay time adjustment also see point 3b Fault current to earth adjustm...

Страница 2: ...minali 20 21 22 che normalmente eccitato Il controllo avviene tramite i terminali 17 18 19 che devono essere cos collegati RESET pushbutton To reset the relay after tripping For remote reset of R1D si...

Страница 3: ...avi della linea da controllare inserire le fasi e il neutro se presente Il cavo di terra NON deve attraversare il trasformatore di corrente Versions RM RMT Tripping delay time adjustment also see poin...

Страница 4: ...nx10 constant selection for fault current to earth adjustment The constants in relation to the position of the 2 dip switches are the following dip switch position I nx0 1 and I nx0 1 K 0 1 dip switch...

Страница 5: ...15 4 1 3 5 N L1 L2 L3 Trip 5 4 24VAC DC 5 3 48VAC DC 5 1 380 415VAC 5 3 220 240VAC 5 4 110 125VAC DC RMT Terra GRD Linea Load Carico Load K Bobina di apertura Shunt coil Terra GRD Linea Load Carico Lo...

Страница 6: ...110 70 60 47 60 60 50 RC80 150 160 70 80 70 110 60 50 RC110 150 160 70 110 70 110 60 50 E RC 96 90 66 96 85 16 19 91 91 R3 R4D TIPO A B C D E F G H K RT35 100 110 50 35 47 60 43 30 RT60 100 110 50 60...

Страница 7: ...380 415VAC 110 125VAC DC 220 240 380 415VAC 220 240 380 415VAC Frequenza nominale 50 60Hz 50 60Hz 50 60Hz 50 60Hz 50 60Hz Potenza massima assorbita 5 5VA 4 5VA 4 5VA 5 5VA 3VA REL DI USCITA Stato del...

Страница 8: ...220 240 380 415VAC 110 125VAC DC 220 240 380 415VAC 220 240 380 415VAC Rated frequency 50 60Hz 50 60Hz 50 60Hz 50 60Hz 50 60Hz Maximum power consumption 5 5VA 4 5VA 4 5VA 5 5VA 3VA OUTPUT RELAYS State...