DECLARATION OF COMPLIANCE
The manufacturer declares that the appliances are compliant with the prescriptions of the EEC norm 90/396 for the gas
part and with norm 73/23 for the electric part. The installation must be done observing the norms in force particularly
concerning room ventilation and discharging gas emissions.
N.B.: The manufacturer declines any responsibility for direct or indirect damage caused by improper or incorrect
installation, alterations, maintenance or use of the appliance, as in all the other cases considered in the items of our sales
conditions.
TECHNICAL DATA TABLE
MODEL
DIMENSIONS
cm
NOMINAL HEAT OUTPUT
TOTAL KW
GAS CONNECTION
Electric
(230 Vac-1)
Gas
ISO 7-1
F18-94G
40x90x90h
0,005
15
R 3/4GM
F25-94G
40x90x90h
0,005
20
R 3/4GM
F2/18-98G
80x90x90h
0,01
30
R 3/4GM
F2/25-98G
80x90x90h
0,01
40
R 3/4GM
F13T-94G
40x90x29h
/
12
R ½GM
F2/13T-98G
80x90x29h
/
24
R ½GM
F2/8-94G
40x90x90h
/
10
R ½GM
F2/8T-94G
40x90x29h
/
9
R ½GM
INSTALLING THE APPLIANCE
•
The operations for installing, conversions for use with other types of gas and starting up must be done only by
qualified personnel whose qualifications comply with the norms in force.
•
The gas installation, the electrical connections and the rooms in which the appliances are installed must comply
with the norms in force in the Country in which the installation is effect; above all, the appliance must be installed
in a well ventilated room, preferably under an extractor hood, so as to ensure the complete extraction of gas
emissions which are formed during combustion. The air necessary for combustion is 2
3
m /h per kW of power
installed.
ELECTRICAL CONNECTION
The power lead is supplied with the appliance.
The connecting terminal block is behind the front protection panel.
To replace the power lead proceed in the following way:
- Disconnect power.
- Remove the front protection panel.
- Disconnect the cable from the leading in terminal block.
- Loosen the clamp and pull the cable out.
- Put the new power lead through the clamp, connect the wires to their relative terminals on the terminal block and fix
them.
- Lock the lead with the clamp and put the front protection panel back in place. The earth wire must be longer than the
others so that if the clamp breaks, it comes away after the electricity cables.
EQUIPOTENTIAL
The appliance must be connected to an equipotential system.
The connection screw is positioned at the back of the appliance and is identified by the
symbol.
Attention! The manufacturer will neither be held responsible for, nor will give any compensation during the guarantee
period for any damage caused, and which is due to inadequate installations not compliant with the instructions.
CHECKING FOR ADEQUATE VENTILATION
Make sure that the air intake into the room where the appliance is installed is sufficient for an adequate change of air, as