28
Installation in vertical position
(drawing 4)
•
Insert the pipe
TFM
on the connection plate
PRT
and secure it using a hose clamp. In alternative, the pipe can be
inserted directly into the hole made on the machine tool cabin.
•
Insert the other end of the pipe into the suction mouth of the
DARWIN
and secure it using a hose clamp.
•
Insert the oil drainage pipe
TFD
in the oil discharge pipe of the
DARWIN
and secure it using a hose clamp.
•
Insert the other end of the drainage pipe into the hole made on the machine tool cabin. In alternative, in case you
prefer not to re-use the re-condensed oil, insert the other end of the drainage pipe into an open container to be
regularly emptied.
VERTICAL INSTALLATION
Drawing 4:
Vertical installation
Installation in horizontal position
(drawing 9)
•
Insert the pipe
TFM
on the connection plate
PRT
and secure it using a hose clamp. In alternative, the pipe can be
inserted directly into the hole made on the machine tool cabin.
•
Insert the other end of the pipe into the suction mouth of the
DARWIN
and secure it using a hose clamp.
•
Insert the oil drainage pipe
TFD
in the oil discharge pipe of the
DARWIN
and secure it using a hose clamp.
Insert the other end of the drainage pipe into the hole made on the machine tool cabin. In alternative, in case you prefer not
to re-use the re-condensed oil, insert the other end of the drainage pipe into an open container to be regularly emptied.
Note!
To ensure optimum functioning of the
DARWIN in both mounting positions:
•
Do not obstruct the inlet
•
Do not obstruct the exit of the drainage hose.
HORIZONTAL INSTALLATION
Drawing 5:
Horizontal installation
EN