Appendix B
7-4
Press the space bar to view the next page showing the rest of the time slots of PORT A (time slots 17-31).
LOOP V4200-9 === System Setup ( MAP ) === 09:25:55 09/06/2000
ARROW KEYS: CURSOR MOVE, Please Input: 0~9, BACKSPACE to edit
PORT A PORT B PORT C PORT D PORT E PORT F PORT H PORT J PORT K PORT Z
TIME FE1 QFXS QFXS QFXS QFXS QFXS QFXS QFXS QFXS Inband
SLOT CAS A-LAW A-LAW A-LAW A-LAW A-LAW A-LAW A-LAW A-LAW
==== ======= ======= ======= ======= ======= ======= ======= ======= ======= ========
17 v E 04
18 v F 01
19 v F 02
20 v F 03
21 v F 04
22 v H 01
23 v H 02
24 v H 03
25 v H 04
26 v J 01
27 v J 02
28 v J 03
29 v J 04
30 v K 01
31 v K 02
<< ESC key to previous menu, SPACE key to another page >> PAGE2
The normal configuration for a channel bank is now complete.
Press ESC and save the configuration.
Note:
If common channel signaling is used, time slot 16 can be used to carry the signaling channel.
However, to insert the signaling channel, a data card, such as a V.35 card, must be plugged into one
of the ports. PORT A must be configured to NON-CAS and time slot 16 of PORT A must be labeled d
for data. The port taken by the data card will decrease the number of available voice channels carried
to 28.
Finally, the new configurations should be STORED so they will not be deleted upon a power reset.
Press ESC to return to the main menu.
Press “R” to activate the Store/Retrieve Configuration screen
LOOP V4200-9 === Controller Menu === 10:48:35 0 9 / 0 6 / 2 0 0 0
Serial Number: 10001 Connect_port: SUPV_PORT
V e r s i o n : H W H / W V E R . E S W S 3 . Q 4 0 5 / 2 4 / 2 0 0 2
S t a r t T i m e : 1 5 : 3 5 : 1 7 0 6 / 2 5 / 2 0 0 2 P W R 1 : a c t i v e P W R 2 : a c t i v e
[Port Status]
A B C D E F H J K
FE1 QFXS QFXS QFXS QFXS QFXS QFXS QFXS QFXS
[DISPLAY] [SETUP]
C -> Display System Configuration S -> System Setup
Q -> Alarm Queue Summary P -> Password Setup
I -> Information Summary M -> System Alarm Setup
L -> Download/Upload Firmware
T -> Download/Upload Configuration
R
-> Store/Retrieve Configuration
[LOG] [MISC]
U -> Choose a Unit A -> Alarm Cut Off
F -> Log Off [SETUP],[MISC] Menu X -> Clear Alarm Queue
O -> Log On [SETUP],[MISC] Menu Y -> Controller Return to Default
Z -> Controller Reset
K -> Load All Ports Default
>>SPACE key to refresh or enter a command ===>