7
Panel Mounting and Installation - Class II
Install the meters in a suitable protective electrical control enclosure according to local wiring
regulations. See specifications for maximum allowable temperature in enclosure. Allow
adequate air circulation.
888888
92mm +1mm -0mm
45mm +1mm -0mm
Panel cutout
Installing into front of panel
Remove the two rear bracket
screws and safely store them
and the U-Bracket for later fitting.
Gasket
Gasket
Front surface
of enclosure
Front surface
of enclosure
Front surface
of meter
U-Bracket
Bracket screw (1 of 2)
Left side of meter case
U-Bracket
Bracket screws
U-Bracket
Bracket screws
Slide the meter, with gasket
into the panel cutout
Securing into the panel
Re-fit the U-Bracket and tighten the bracket
screws to firmly clamp the meter in place.
Check that the gasket is evenly pinched
between the meter’s front bezel and the
enclosure front
Ventilation
There should be sufficient ventilation in the
enclosure to ensure that the meter’s case is
always kept to less than 60C.
Meter Spacing.
Meters should be spaced apart sufficiently
to allow a free flow of ventilation air around
the meters, such that no part of the case will
exceed 60C
Side view of meter installed in panel