COMPILER TECO/ATL
REG. CODE
1-5302-509
MODEL N°
50778
DATE OF ISSUE
10.06.99
REVISION
00
ENDORSED
DATE
10.06.99
87
XV
LPG fuelled ENGINE LGW 627
Electrical system
This is an essential component on which the correct operation of the entire system depends.
Comply with the following rules:
- all conductors must be equipped with insulation and protection and be installed in a perfectly workmanlike way;
- the electrical circuit must be equipped with a current limiting device;
- the voltage and current ratings must not exceed the values established by the specifications of each connector;
- the electric leads must be routed as far away as possible from the high voltage cables of the ignition system;
- the best way to connect between cables is by using terminals or connectors duly insulated from the cables themselves.
Change-over switch Mod. 093
Change-over switch Mod. 093 is used in LPG conversion systems in vehicles with carburetors.
Designed for easy installation on any type of dashboard, it includes the following components:
- gas-gasoline (petrol) switch;
- safety device that shuts off the supply to the solenoid valves if the engine accidentally stops;
- adjustable priming time.
Mod. 093 change-over switch installation
Change-over switch Mod. 093 can be installed in two different ways:
1) in the conventional way, using the relative bracket with screws;
2) by fitting into the dashboard after having made a rectangular hole in it of the required size (approx. 25x28 mm) using the
relative cutter
Install the change-over switch where it is protected from water
Priming time setting
The trimmer (A) used to set the priming time is behind the change-
over switch housing.
The priming time must be set according to the type of regulator in
question (normal or SIC), the length of the tube between the reducer
and mixer and the swept volume of the vehicle.
The priming time can be set from a minimum of 0 seconds to a
maximum of 4 seconds, by turning the trimmer in a clockwise
direction.
To check and regulate the priming time, shut off the gas
supply from the tank and measure the time according to the
noise issued by the solenoid valve.
1 Green led indicating that the engine is fuelled with LPG
2 Switch to change from gasoline (petrol) to gas fuelling and vice
versa, with the reservoir emptying position in the center. All the
leds will be off when the switch is in the central position
3 Yellow led indicating that the engine is fuelled with gasoline (petrol)
Consult the relative wiring diagram on page 81, fig. 183, for the electrical connections
190