LOKERMANN GRAND ARC 320 CEL PFC MV Скачать руководство пользователя страница 3

INSTALLATION WARNING

This machine is certified according to 60974-10:2014 Arc Welding Equipment Part 10: Electromagnetic 

compatibility (EMC) requirement and the EUT belongs to Group 2 Class A.

WARNING: This Class A equipment is intended for industrial use and it is not intended for use in 

residential locations where the elctrical power is provided by the public low-voltage supply system. 

There may be potential difficulties in ensuring electromagnetic compatibility in those locations, due to 

conducted as well as radiated disturbances.

WARNING: This equipment does not comply with IEC 61000-3-12. If it is connected to a public low-

voltage system, it is the responsability of the installer or user of the equipment to ensure, by consultation 

with the distribution network operator if necessary, that the equipment may be connected.

Assessment of area

Before installing arc welding equipment the user shall make an assessment of potential

electromagnetic problems in the surrounding area. The following shall be taken into account:

a) other supply cables, control cables, signalling and telephone cables, above, below and

adjacent to the arc welding equipment;

b) radio and television transmitters and receivers;

c) computer and other control equipment;

d) safety critical equipment, for example guarding of industrial equipment;

e) the health of the people around, for example the use of pacemakers and hearing aids;

f) equipment used for calibration or measurement;

g) the immunity of other equipment in the environment. The user shall ensure that other

equipment being used in the environment is compatible. This may require additional

protection measures;

h) the time of day that welding or other activities are to be carried out.

The size of the surrounding area to be considered will depend on the structure of the building

and other activities that are taking place. The surrounding area may extend beyond the

boundaries of the premises.

Methods of reducing emissions-Public supply system

Arc welding equipment should be connected to the public supply system according to this manual 

recommendations. If interference occurs, it may be necessary to takeadditional precautions such as 

filtering of the public supply system. Consideration should be given to shielding the supply cable of 

permanently installed arc welding equipment, in metallic conduit or equivalent. Shielding should be 

electrically continuous throughout its length. The shielding should be connected to the welding power 

source so that good electrical contact is maintained between the conduit and the welding power 

source enclosure.

Maintenance of the arc welding equipment

The arc welding equipment should be routinely maintained according to this manual

recommendations. All access and service doors and covers should be closed and properly

fastened when the arc welding equipment is in operation. The arc welding equipment should

not be modified in any way, except for those changes and adjustments covered in this manaul. In 

particular, the spark gaps of arc striking and stabilising devices

should be adjusted and maintained according to our recommendations.

Welding cables

The welding cables should be kept as short as possible and should be positioned close

together, running at or close to the floor level.

Equipotential bonding

Bonding of all metallic objects in the surrounding area should be considered. However,

metallic objects bonded to the work piece will increase the risk that the operator could receive

an electric shock by touching these metallic objects and the electrode at the same time. The

operator should be insulated from all such bonded metallic objects.

Earthing of the workpiece

Where the workpiece is not bonded to earth for electrical safety, nor connected to earth

because of its size and position, for example, ship’s hull or building steelwork, a connection

bonding the workpiece to earth may reduce emissions in some, but not all instances. Care should be 

taken to prevent the earthing of the workpiece increasing the risk of injury to users or damage to other 

electrical equipment. Where necessary, the connection of the workpiece to earth should be made by 

a direct connection to the workpiece, but in some countries where direct connection is not permitted, 

the bonding should be achieved by suitable capacitance, selected according to national regulations.

Screening and shielding

Selective screening and shielding of other cables and equipment in the surrounding area may

alleviate problems of interference. Screening of the entire welding area may be considered for

special applications.

1

Installation

warning

Содержание GRAND ARC 320 CEL PFC MV

Страница 1: ...IMPORTANT Read this OPERATOR MANUAL together with PRESCRIPTION AND COMPLIANCE MANUAL before to use this equipment In case of loss one of two parts contact immediately your dealer Allow the operator to...

Страница 2: ...2 2 Operation for MMA Welding 3 2 3 MMA Welding 3 2 4 MMA Welding Fundamentals 3 2 5 MMA Welding trouble shooting 3 2 6 Wireless Remote control Configuration 3 3 Installation Operation for TIG Weldin...

Страница 3: ...ly system Consideration should be given to shielding the supply cable of permanently installed arc welding equipment in metallic conduit or equivalent Shielding should be electrically continuous throu...

Страница 4: ...A 60 175A 60 245A 100 120A 100 70A 100 180A 100 135A 100 190A Welding Current Range A 10 150 10 120 10 250 10 200 10 315 No Load Voltage V 13 TIG 80 MMA Efficiency 85 Power Factor 0 99 Insulation clas...

Страница 5: ...n all position GRAND ARC 320 CEL PFC MV can also realize TIG operation While MMA operation if the electrode touches workpiece over two seconds the welding current will drop to the minimum current auto...

Страница 6: ...t feedback control technology to insure current output stability Meanwhile the welding current parameter can be adjusted continuously and steplessly to meet with the requirements of welding craft GRAN...

Страница 7: ...ital multifunction display 9 Alarm indicator 10 Power Indicator lights when input power connected and machine switched on 11 Lift TIG mode indicator 12 MMA VRD mode indicator 13 MMA mode indicator 14...

Страница 8: ...ow This effect will also cause the welding current to increase 0 is Arc Force off 10 is maximum Arc Force This is practically useful for electrode types that have a higher operating voltage requiremen...

Страница 9: ...Force using the knob 5 Place the electrode into the electrode holder and clamp tight 6 Strike the electrode against the work piece to create and arc and hold the electrode steady to maintain the arc 7...

Страница 10: ...and becomes the deposited weld metal The deposit is covered and protected by a slag which comes from the electrode coating The arc and the immediate area are enveloped by an atmosphere of protective...

Страница 11: ...ng reduces penetration produces spatter and gives a rough surface finish to the weld An excessively short arc will cause sticking of the electrode and result in poor quality welds General rule of thum...

Страница 12: ...se oil and dirt including mill scale from base metal Poor welding technique Use the correct welding technique or seek assistance for the correct technique 5 Lack of penetration Insufficient heat input...

Страница 13: ...time pressing any buttons on the remote control panel or foot pedal the digital meter on the front panel of the welding power supply flick twice to indicate the synchronization is successful and comp...

Страница 14: ...t is only 28A After generating arc current can rise to the setting welding current If the tungesten electrode touches the workpiece when welding the current will drop to 5A within 2s which can reduce...

Страница 15: ...tal Incorrect filler wire Check the filler wire and change if necessary 4 Yellowish residue smoke on the alumina nozzle discoloured tungsten Incorrect Gas Use pure Argon gas Inadequate gas flow Set th...

Страница 16: ...h the arc in unprotected eyes Ensure good ventilation of the machine to improve Duty Cycle Turn off the engine when the operation finished for energy consumption efficiency When power switch shuts off...

Страница 17: ...lease replace the damaged LED If it still doesn t work please maintain or replace the display PCB Observe that the min max values on LED agree with the set value If there is any difference and it has...

Страница 18: ...ce 8 The welding current can not be adjusted Welding current potentiometer in the front panel connection not so good or damaged Repair or change the potentiometer 9 The penetration of molten pool is n...

Страница 19: ...4 4 Electrical schematic drawing...

Страница 20: ...LOKERMANN Srl Via Produzione 16 18 37044 Cologna Veneta VR Italy Tel 39 0442 1722469 lokermann lokermann eu www lokermann eu...

Отзывы: