4.2 

Troublesho-

oting

-     

Before the welding machines are dispatched from the factory, they have already been tested and 

    calibrated accurately. It is forbidden for anyone who is not authorized by our company to do any 
    change to the equipment.

-     

Maintenance course must be operated carefully. If any wire becomes flexible or is misplaced, it maybe potential 

     danger to user.

-     

Only professional maintenance staff that isauthorized by our company could overhaul the machine.

-     

Be sure to shut off the Main Input Power before doing any repair work on the welding machine.

-     

If there is any problem and there is no authorized professional maintenance personal on site, please contact local 

     agent or the distributor.
If there are some simple troubles with the welding machine, you can consult the following chart: 

 

 

Date 

Maintenance items 

Daily 

examinati

on 

Observe that the knobs and switches in the front and at the back of arc 

welding machine are flexible and put correctly in place.  If any knob has not 

been put correctly in place, please correct.  If you can't correct or fix the knob, 

please replace immediately;  

If any  

switch is not flexible or it can't be put correctly in place, please replace  

immediately.  Please get in touch with maintenance service department if there 

are no accessories. 

After turn-on power, watch/listen if the arc-welding  machine has shaking, 

whistle calling or peculiar smell.  If there is one of the above problems, find out 

the reason and clear it. If you can't find out the reason, please contact your local 

service repair station or distributor/agent .  

Observe that the display value of LED is intact. If the display number is  

not 

intact, please replace the damaged LED.  If it still doesn’t work, please maintain 

or replace the display PCB.  

Observe that the min/max values  

on  

LED agree with the set value. If there is 

any difference and it has affected the normal welding results, please adjust it. 

Check whether the fan is damaged and whether it is normal to rotate or 

control.  If the fan is damaged, please change immediately.  If the fan  does not 

rotate after the machine is overheated, observe if there is something blocking 

the blade.  If it is blocked, please clear the problem.  If the fan does not rotate 

after getting rid of the above problems, you can poke the blade by the rotation 

direction of fan. If the fan rotates normally, the start capacity should be 

replaced.  If not, change the fan.   

Observe whether the fast connector is loose or overheated. If  the arc- welding  

machine has the above problems, it should be fastened or changed.  

Observe whether the current output cable is damaged. If it is damaged, it 

should be insulated or changed.  

Monthly 

examinati

on 

Using the dry compressed air to clear the inside of arc welding machine. 

Especially for clearing up the dusts on radiator, main voltage transformer, 

inductors, IGBT modules, fast recover diodes, PCB’s, etc.  

Check the screws  

and bolts  

in the machine. If any is loose, please screw it 

tight.  If it is shaved, please replace. If it is rusty, please erase rust on all bolts to 

ensure it works well. 

Quarter- 

yearly 

examinati

on 

Check whether the actual current accords with the displaying value. If they did 

not accord, they should be regulated. The actual welding current value can be 

measured by and adjusted by plier-type ampere meter.  

Yearly 

examinati

on 

Measure the insulating impedance among the main circuit, PCB and case, if it 

below 1M

Ω

, insulation is thought to be damaged and need to change, and need 

to change or strengthen insulation.  

 

Содержание GRAND ARC 320 CEL PFC MV

Страница 1: ...IMPORTANT Read this OPERATOR MANUAL together with PRESCRIPTION AND COMPLIANCE MANUAL before to use this equipment In case of loss one of two parts contact immediately your dealer Allow the operator to...

Страница 2: ...2 2 Operation for MMA Welding 3 2 3 MMA Welding 3 2 4 MMA Welding Fundamentals 3 2 5 MMA Welding trouble shooting 3 2 6 Wireless Remote control Configuration 3 3 Installation Operation for TIG Weldin...

Страница 3: ...ly system Consideration should be given to shielding the supply cable of permanently installed arc welding equipment in metallic conduit or equivalent Shielding should be electrically continuous throu...

Страница 4: ...A 60 175A 60 245A 100 120A 100 70A 100 180A 100 135A 100 190A Welding Current Range A 10 150 10 120 10 250 10 200 10 315 No Load Voltage V 13 TIG 80 MMA Efficiency 85 Power Factor 0 99 Insulation clas...

Страница 5: ...n all position GRAND ARC 320 CEL PFC MV can also realize TIG operation While MMA operation if the electrode touches workpiece over two seconds the welding current will drop to the minimum current auto...

Страница 6: ...t feedback control technology to insure current output stability Meanwhile the welding current parameter can be adjusted continuously and steplessly to meet with the requirements of welding craft GRAN...

Страница 7: ...ital multifunction display 9 Alarm indicator 10 Power Indicator lights when input power connected and machine switched on 11 Lift TIG mode indicator 12 MMA VRD mode indicator 13 MMA mode indicator 14...

Страница 8: ...ow This effect will also cause the welding current to increase 0 is Arc Force off 10 is maximum Arc Force This is practically useful for electrode types that have a higher operating voltage requiremen...

Страница 9: ...Force using the knob 5 Place the electrode into the electrode holder and clamp tight 6 Strike the electrode against the work piece to create and arc and hold the electrode steady to maintain the arc 7...

Страница 10: ...and becomes the deposited weld metal The deposit is covered and protected by a slag which comes from the electrode coating The arc and the immediate area are enveloped by an atmosphere of protective...

Страница 11: ...ng reduces penetration produces spatter and gives a rough surface finish to the weld An excessively short arc will cause sticking of the electrode and result in poor quality welds General rule of thum...

Страница 12: ...se oil and dirt including mill scale from base metal Poor welding technique Use the correct welding technique or seek assistance for the correct technique 5 Lack of penetration Insufficient heat input...

Страница 13: ...time pressing any buttons on the remote control panel or foot pedal the digital meter on the front panel of the welding power supply flick twice to indicate the synchronization is successful and comp...

Страница 14: ...t is only 28A After generating arc current can rise to the setting welding current If the tungesten electrode touches the workpiece when welding the current will drop to 5A within 2s which can reduce...

Страница 15: ...tal Incorrect filler wire Check the filler wire and change if necessary 4 Yellowish residue smoke on the alumina nozzle discoloured tungsten Incorrect Gas Use pure Argon gas Inadequate gas flow Set th...

Страница 16: ...h the arc in unprotected eyes Ensure good ventilation of the machine to improve Duty Cycle Turn off the engine when the operation finished for energy consumption efficiency When power switch shuts off...

Страница 17: ...lease replace the damaged LED If it still doesn t work please maintain or replace the display PCB Observe that the min max values on LED agree with the set value If there is any difference and it has...

Страница 18: ...ce 8 The welding current can not be adjusted Welding current potentiometer in the front panel connection not so good or damaged Repair or change the potentiometer 9 The penetration of molten pool is n...

Страница 19: ...4 4 Electrical schematic drawing...

Страница 20: ...LOKERMANN Srl Via Produzione 16 18 37044 Cologna Veneta VR Italy Tel 39 0442 1722469 lokermann lokermann eu www lokermann eu...

Отзывы: