The table below shows a list of the parameters and values used by the 

Logitrans controller

 and the 

equipment needed to read and/or set them.

A:  The values can be read on a display/battery indicator fitted to the truck (Panther MAXI/SELF).

B:  The parameters/values can be set/read by means of a hand terminal.

C:  The parameters/values can be set/read by means of a PC.

D:  The value is factory-set as standard on Panther MINI/MAXI 

E:  The value is factory-set as standard on SELF.

 

     Parameter (can be set) 

Text in hand terminal  A  B  C 

E

  1  Max. speed 

Maximum speed 

 

100% 

100%

  2  1st. reduced speed 

1. reduced speed 

 

100% 

34,5%

  3  2nd. reduced speed 

2. reduced speed 

 

34,5% 

34,5%

  4  Minimum output 

 

 

 

9,8% 

9,8%

  5  Safety forward output 

 

 

 

49,8% 

49,8%

  6  Max. current 

Maximum current 

 

200A 

200A

  7  Acceleration slope 

Acc. slope 

 

1,50s 

3,00s

  8  Max. temperature 

 

 

 

74°C 

74°C

  9  Safety forward time 

 

 

 

5,0s 

5,0s

  10  Battery 90% 

Battery 90% 

 

24,14V  24,14V

  11  Battery 70% 

Battery 70% 

 

23,84V  23,84V

  12  Battery 50% 

Battery 50% 

 

23,54V  23,54V

  13  Battery 25%  

Battery 25% 

 

23,24V  23,24V

  14  Battery 15%  

Battery 15% 

 

22,95V  22,95V

  15  Battery charging voltage 

 

 

 

27,52V  27,52V

  16  A/D start voltage 

 

 

 

2,35V 

2,35V

  17  A/D 100% voltage 

 

 

 

1,82V 

1,82V

      Value (cannot be set) 

Text in hand terminal  A  B  C

  18  Total hours 

Total hours 

X

  19  Subtotal hours 

Subtotal hours 

X

  20  No of charges 

No of charges 

 

X

  21  No of discharges 

No of discharges 

 

X

  22  Serial no. 

 

 

 

X

  23  Programme version 

 

 

 

X

  24  Memory 

 

 

 

X

  25  Error counters 

 

 

 

X

  26  Error messages 

 

 

  27  Battery meter 

 

 

Electric system 

Electronic control Logitrans Controller 

Содержание LOGIFLEX SELF 1001

Страница 1: ...SERVICE MANUAL LOGIFLEX SELF 1001 PANTHER MINI PM 1400 PANTHER MAXI PM 1800 www logitrans com www www logitrans com...

Страница 2: ......

Страница 3: ...t 2 Electric diagrams 3 Hydraulic diagrams 4 Instructions and forms for Service Check Contents Logitrans controller 4 Comments 6 Operating messages in mini display for Logitrans Controller 8 Controlle...

Страница 4: ...of battery charging cycles carried out Counter for the number of battery discharges to under 15 of battery capacity that have occurred The serial no of the controller is printed on the side of the box...

Страница 5: ...8 5 Safety forward output X 49 8 49 8 6 Max current Maximum current X X 200A 200A 7 Acceleration slope Acc slope X X 1 50s 3 00s 8 Max temperature X 74 C 74 C 9 Safety forward time X 5 0s 5 0s 10 Bat...

Страница 6: ...rive grip is turned 5 Safety forward power The maximum power sent to the motor when the safety switch is activated Acceleration is the same as normal operation see point 7 6 Maximum power The maximum...

Страница 7: ...r counters The following event counters can be seen in the PC program Current limiter forwards current limiter reverse Counts the number of times the maximum current for operations forwards reverse ha...

Страница 8: ...verloaded After a short pause operation can be restarted If appropriate check the parameter Maximum current in the PC program Motor control overheat Motor overloaded After a pause of a few minutes ope...

Страница 9: ...Controller error Error on controller Error on the display Cause 10 Hall_forward input 11 Hall_forward 12 Hall_reserve input 13 Hall_reserve 14 Hall forward and reserve 20 Memory 21 Memory 22 Memory 30...

Страница 10: ...e defective 14 Hall forward and reverse Lead to 5 volt for Hall_PCB can be defective Error code 14 or 31 is in 95 of the cases caused by the battery or a bad connection A Make sure that the battery is...

Страница 11: ...ber 2007 serial no 074E24051530 please set the controller parameter 2nd reduced speed to 34 5 This will reduce the speed when the battery is 85 discharged 30 Power system for forward This fault can al...

Страница 12: ...tment thus Loosen 3 screws A Adjust 3 screws B until C is 0 2 mm Tighten screws A while holding screws B Check clearance C When the brake lining has worn to less than 5 mm E it must be replaced Under...

Страница 13: ...Pump unit Hydraulic oil Oil change Draining of oil Filling in oil Oil quantity Lubrication Battery Brushes in the pump motor It is not possible to change brushes in the pump motor Described in the man...

Страница 14: ...www logitrans com www www logitrans com S928 10 02 2010...

Отзывы: