5
The table below shows a list of the parameters and values used by the
Logitrans controller
and the
equipment needed to read and/or set them.
A: The values can be read on a display/battery indicator fitted to the truck (Panther MAXI/SELF).
B: The parameters/values can be set/read by means of a hand terminal.
C: The parameters/values can be set/read by means of a PC.
D: The value is factory-set as standard on Panther MINI/MAXI
E: The value is factory-set as standard on SELF.
Parameter (can be set)
Text in hand terminal A B C
D
E
1 Max. speed
Maximum speed
X
X
100%
100%
2 1st. reduced speed
1. reduced speed
X
X
100%
34,5%
3 2nd. reduced speed
2. reduced speed
X
X
34,5%
34,5%
4 Minimum output
X
9,8%
9,8%
5 Safety forward output
X
49,8%
49,8%
6 Max. current
Maximum current
X
X
200A
200A
7 Acceleration slope
Acc. slope
X
X
1,50s
3,00s
8 Max. temperature
X
74°C
74°C
9 Safety forward time
X
5,0s
5,0s
10 Battery 90%
Battery 90%
X
X
24,14V 24,14V
11 Battery 70%
Battery 70%
X
X
23,84V 23,84V
12 Battery 50%
Battery 50%
X
X
23,54V 23,54V
13 Battery 25%
Battery 25%
X
X
23,24V 23,24V
14 Battery 15%
Battery 15%
X
X
22,95V 22,95V
15 Battery charging voltage
X
27,52V 27,52V
16 A/D start voltage
X
2,35V
2,35V
17 A/D 100% voltage
X
1,82V
1,82V
Value (cannot be set)
Text in hand terminal A B C
18 Total hours
Total hours
X
X
X
19 Subtotal hours
Subtotal hours
X
X
X
20 No of charges
No of charges
X
X
21 No of discharges
No of discharges
X
X
22 Serial no.
X
23 Programme version
X
24 Memory
X
25 Error counters
X
26 Error messages
X
27 Battery meter
X
Electric system