background image

11

Electric system 

Electronic control - Controller-error

20, 21 and 22 Memory

 

Error 2 is a fault in the eprom (memory) in the controller. 

Error 2 is often caused by a deep discharged battery, where the controller drops out with an error 14 

because of the low voltage. If this happens during a write process in the controller, where drive hours etc. 

are being stored, the error 2 will occur. 

Other fault causes:

not all legs inside the multi plugs connected to the controller is at equal height

• 

a broken battery indicator house. Water could make corrosion on the electrical print

• 

a squeezed wire to the battery indicator

• 

To repair the controller, reset it by removing the 5 A fuse. After 2 minutes insert the fuse again and see, if 

the error code 2 has been reset. If the fault is not reset, the controller will have to be replaced or repaired. 

Repair is only possible in Logitrans DK. 

To avoid this deep-discharged battery on trucks delivered before 28 November 2007 (serial no. 

074E24051530), please set the controller parameter ”2nd reduced speed” to 34,5%. This will reduce the 

speed, when the battery is 85% discharged.

30. Power system for forward

 

This fault can also occur if more current is to be transferred to the motor than specified in the operating 

parameter 

Maximum current

. If the fault repeats itself, contact Logitrans.

31. Power system for reverse

 

As above. Please also see the error description under “error 14”.

40. Temperature error on the controller

This error code should only arise, if the temperature inside the controller exceeds 74º. The error will nor-

mally disappear, as soon as the temperature drops. If the error code does not disappear by itself, reset the 

controller by removing the 5 A (7,5 A) fuse.

50. Defective controller

Error code 5 indicates a short circuit in the controller. In some cases the error diode will be on. Remove 

the current for the controller by removing the 5 A (7.5 A) control current fuse for 1 minute. Place the fuse 

again. A defective battery or loose battery cables will also result in error code 5. 

If the error code 5 does not disappear, the controller has to be exchanged.

Содержание LOGIFLEX SELF 1001

Страница 1: ...SERVICE MANUAL LOGIFLEX SELF 1001 PANTHER MINI PM 1400 PANTHER MAXI PM 1800 www logitrans com www www logitrans com...

Страница 2: ......

Страница 3: ...t 2 Electric diagrams 3 Hydraulic diagrams 4 Instructions and forms for Service Check Contents Logitrans controller 4 Comments 6 Operating messages in mini display for Logitrans Controller 8 Controlle...

Страница 4: ...of battery charging cycles carried out Counter for the number of battery discharges to under 15 of battery capacity that have occurred The serial no of the controller is printed on the side of the box...

Страница 5: ...8 5 Safety forward output X 49 8 49 8 6 Max current Maximum current X X 200A 200A 7 Acceleration slope Acc slope X X 1 50s 3 00s 8 Max temperature X 74 C 74 C 9 Safety forward time X 5 0s 5 0s 10 Bat...

Страница 6: ...rive grip is turned 5 Safety forward power The maximum power sent to the motor when the safety switch is activated Acceleration is the same as normal operation see point 7 6 Maximum power The maximum...

Страница 7: ...r counters The following event counters can be seen in the PC program Current limiter forwards current limiter reverse Counts the number of times the maximum current for operations forwards reverse ha...

Страница 8: ...verloaded After a short pause operation can be restarted If appropriate check the parameter Maximum current in the PC program Motor control overheat Motor overloaded After a pause of a few minutes ope...

Страница 9: ...Controller error Error on controller Error on the display Cause 10 Hall_forward input 11 Hall_forward 12 Hall_reserve input 13 Hall_reserve 14 Hall forward and reserve 20 Memory 21 Memory 22 Memory 30...

Страница 10: ...e defective 14 Hall forward and reverse Lead to 5 volt for Hall_PCB can be defective Error code 14 or 31 is in 95 of the cases caused by the battery or a bad connection A Make sure that the battery is...

Страница 11: ...ber 2007 serial no 074E24051530 please set the controller parameter 2nd reduced speed to 34 5 This will reduce the speed when the battery is 85 discharged 30 Power system for forward This fault can al...

Страница 12: ...tment thus Loosen 3 screws A Adjust 3 screws B until C is 0 2 mm Tighten screws A while holding screws B Check clearance C When the brake lining has worn to less than 5 mm E it must be replaced Under...

Страница 13: ...Pump unit Hydraulic oil Oil change Draining of oil Filling in oil Oil quantity Lubrication Battery Brushes in the pump motor It is not possible to change brushes in the pump motor Described in the man...

Страница 14: ...www logitrans com www www logitrans com S928 10 02 2010...

Отзывы: