USER MANUAL SMARTneo //
PAGE 22
Version B (with double-click function)
2
Double-click the required
memory position button
(e.g. 2).
After the double-click, the table top automatically moves to the saved
table top position.
o73
The display shows the current (saved) table top position.
DANGER
Danger of crushing
There is a crushing hazard with an automatic table top position
change. Therefore make sure that there are no items or persons
in the danger zone and that no one reaches into the danger zone.
NOTICE
If you press another button during the automatic adjustment of
the table top to a saved position, the table top will stop immedi-
ately. Then, you have to activate the automatic adjustment of the
table to a saved position again.
DANGER
Increased safety risk
The firmware is delivered with deactivated double-click func-
tion. If you activate the function, the grading of the safety
functions according to EN ISO 13849-1 PL b, Category B, loses its
validity. The legal requirements from the standard are no longer
met with this function.
To use the double-click function, you have to carry out a new
assessment of the higher safety requirements according to EN
60335-1 which cannot be met by this product. LOGICDATA is not
liable for injuries or damage which can result from the activation
of the double-click function.
9.4 MANUAL RESET
If the actual table top position is no longer used with the displayed table top position or an already configu-
red motor control unit on another identically constructed electrically height-adjustable work station, you
have to carry out an end position alignment of the lowest table top position.