background image

DMUI-EASY2MOVE - OPERATING MANUAL // PAGE 4

7.2.1  Saving a Container Stop or Shelf Stop Position 

15

7.2.2  Deleting a Container Stop or Shelf Stop Position  16

7.3  Performing a Position Reset Procedure 

16

7.4  Factory Reset (S0 Reset) 

16

8  System Information 

17

8  Additional Information 

18

8.1  Software-Dependent Functions 

18

8.2 Disassembly 

18

8.3 Maintenance 

18

8.3.1 Cleaning 

18

8.3.2  Replacing a Handset 

18

8.4 Troubleshooting 

18

8.5 Disposal 

18

Содержание DMUI-EASY2move

Страница 1: ...DYNAMIC MOTION DMUI EASY2move DYNAMIC MOTION system User Manual DOCUMENT VERSION 1 AUGUST 2019...

Страница 2: ...ersion 1 0 August 2019 This document was originally published in English LOGICDATA Electronic Software Entwicklungs GmbH Wirtschaftspark 18 8530 Deutschlandsberg Austria Phone 43 0 3462 51 98 0 Fax 43...

Страница 3: ...ymbols and signal words 7 2 6 Liability 7 2 7 Residual risks 8 2 8 Skilled Persons 9 2 9 Notes for Resellers 9 3 Scope of delivery 9 4 Unpackaging 10 5 Products 10 5 1 Key Product Features 10 5 2 Dime...

Страница 4: ...r Stop or Shelf Stop Position 16 7 3 Performing a Position Reset Procedure 16 7 4 Factory Reset S0 Reset 16 8 System Information 17 8 Additional Information 18 8 1 Software Dependent Functions 18 8 2...

Страница 5: ...es in Chapter 2 Safety may be used free of charge by the customer for 10 years after delivery They should be used to prepare end user documentation for height adjustable table systems The license does...

Страница 6: ...al worker protection conditions and national safety and accident prevention regulations are observed during operation of the system 2 3 INTENDED USE The DMUI EASY2move is a Paddle Switch Handset for e...

Страница 7: ...LOGICDATA products comply with all relevant industry standards which are listed in the product s data sheet However risk can result from incorrect operation or misuse LOGICDATA is in particular not li...

Страница 8: ...e housing and cables of the Handset for visible damage Do not install or operate damaged products WARNING Risk of death or serious injury in explosive atmospheres Operating the Handset in potentially...

Страница 9: ...ial language INFO The Charter of the French Language La charte de la langue fran aise or Bill 101 Loi 101 guarantees the right of the population of Quebec to conduct business and commercialactivitiesi...

Страница 10: ...of the packaging material NOTICE Dispose of the packaging material in an environmentally friendly manner Remember to separate plastic parts from the cardboard packaging 5 PRODUCT The illustrations in...

Страница 11: ...UAL PAGE 11 5 2 DIMENSIONS Length 121 82 mm 4 796 Width 47 22 mm 1 859 Height Contact Point to Mounting Point 25 85 mm 1 136 Fig 2 Product dimensions DMUI EASY2move 25 8 5 m m 1 13 6 24 86 mm 0 979 12...

Страница 12: ...mmended Mounting Position the DMUI EASY2move is positioned so that the distance from the front edge of the table to the centre of the first Mounting Point is 40 mm The Handset should not protrude from...

Страница 13: ...during assembly ensure You have measured the dimensions of the product before assembly All parts areacclimatised to the ambient conditions You do not lift the Handset by its cable INFO Perform a prod...

Страница 14: ...all Components have been mounted safely Ensure all Cables are properly connected Ensure that all required Actuators are ready to be operated Do not operate the Table System until it is properly connec...

Страница 15: ...VE Key for 10 seconds The Container Stop Shelf Stop Position is saved Container Stop if you are in the bottom half of the movement area Shelf Stop if you are in the top half 7 2 2 DELETE A CONTAINER S...

Страница 16: ...parameterized with additional stopping points e g a Container Stop Position repeat Step 3 until the table has moved upwards again 7 4 FACTORY RESET S0 RESET With this function you can reset the DYNAM...

Страница 17: ...lease all Keys and wait for 5 seconds Then try to repeat the action again Disconnect the DM System from the Power Unit If a Power Hub is used Disconnect the Power Hub from the Mains Check the Power Un...

Страница 18: ...ANING 1 Disconnect the DYNAMIC MOTION system from the mains 2 Wait 30 seconds for residual voltage to dissipate 3 Wipe the Handset with a dry or slightly damp soft cloth Never immerse the Handset in l...

Страница 19: ...ftspark 18 8530 Deutschlandsberg Austria Phone 43 0 3462 5198 0 Fax 43 0 3462 5198 1030 Email office at logicdata net Internet http www logicdata net LOGICDATA North America Inc Broadmoor Ave SE Suite...

Отзывы: