16
OS 170 Fertilizer Spreader OM
Calibration (VRR Models)
The following chart shows the recommended calibration
numbers for the VRR model spreader.
Calibration
Component
Signal
Type
Calibration
Value
Spinner Speed
Sensor
Pulses Per
Spinner
Revolution
20
Conveyor Speed
Sensor
Pulses Per Drum
Revolution
180
Conveyor Valve
Type
Valve Type
PWM-Close
Valve Calibration
Raven 0043
Deere 1533
Coil Frequency
122 Hz
High limit
255
Low limit
0
Rate Chart Selector
Use the Rate Chart Selector Guide below to determine the correct Application Rate Chart based off of your spreader’s
drive option (hydraulic or mechanical).
The Application Rate Charts are found in this manual and the page numbers are provided within the Rate Chart Selector
Guide below, after each respective chart/decal number.
NOTE:
An Application Rate Chart decal is also applied to the spreader when shipped from the factory that is reflective
of the spreader’s drive option. If changes are made to the spreader’s configuration, and/or a different application setting
is desired, a new decal can be ordered to coincide with the new changes. Refer to “Machine Decals and Signs” on page
61 to order a new decal.
Rate Chart Selector Guide
Driving
Interval (ft)
Conveyor Drive
Mechanical Ground Drive
(11L-15 Tires)
Hydraulic
(Variable Rate Ready)
25
204016 (
page 18)
N129459
(
page 17
)
DIST
204017 (
page 19
)
Set-up and Operation
Содержание OS 170
Страница 2: ......
Страница 4: ......
Страница 8: ...OS 170 Fertilizer Spreader OM ...
Страница 14: ...6 OS 170 Fertilizer Spreader OM OS 170 Fertilizer Spreader Identification Safety Instructions ...
Страница 15: ...7 OS 170 Fertilizer Spreader OM OS 170 Fertilizer Spreader Identification Cont d Safety Instructions ...
Страница 44: ...36 OS 170 Fertilizer Spreader OM ...
Страница 45: ...37 OS 170 Fertilizer Spreader OM PARTS IDENTIFICATION Parts Identification ...
Страница 70: ...62 OS 170 Fertilizer Spreader OM ...
Страница 75: ......