Troubleshooting
26
www.loepfe.com
WeftMaster CUT-iT
5.2
Error messages
Error
Display / cause
Action
01
«NO CUTTING WIRE SET»
No cutter wire diameter is defined in the ba-
sic setting.
Assign an
«industrial electrician / installation
technician»
to carry out the following work:
n
Define the cutter wire diameter.
04
«STILL RUNNING»
Weaving machine not idle during CUT-iT
startup.
Stop weaving machine during CUT-iT
startup.
07
«HARDWARE POWER ERROR»
The supply of the output current is inter-
rupted if the input voltage is outside the lim-
its (17 V-33 V) or if the supply current of 24
V DC is too high due to a hardware error.
Assign an
«industrial electrician / installation
technician»
to carry out the following work:
n
Check power supply.
10
«NO CUTTING WIRE CONNECTED»
No heat cutter is connected or the heat cut-
ter is defective.
Assign an
«industrial electrician / installation
technician»
to carry out the following work:
n
Connect heat cutter
n
Replace heat cutter
n
Repair connection
11
«INPUT VOLTAGE TOO LOW»
Input voltage too low.
n
24V supply voltage is lower than 19V.
Assign an
«industrial electrician / installation
technician»
to carry out the following work:
n
Check input voltage.
13
«RUNS PRO 2 MIN»
Too many runs / stops during the last 2 min-
utes.
Wait and clear error.
14
«MAX BOARD TEMP»
Board temperature too high.
n
The ambient temperature is too high or
the natural cooling of CUT-iT is
insufficient.
15
«NO SLAVE(S)»
CUT-iT is set in Master/Slave mode but
fewer Slaves are detected in the network
than set.
Check the number of Slaves set.
16
«NO MASTER»
CUT-iT is set in Master/Slave mode but no
Master is detected in the network.
Check Master/Slave connection.
Содержание WeftMaster CUT-iT
Страница 1: ...Instruction Manual WeftMaster CUT iT 47083003 en Original Manual Version 1 0 x x 10 2019 ...
Страница 2: ......
Страница 4: ......
Страница 6: ...Contents 6 www loepfe com WeftMaster CUT iT ...