7 Troubleshooting
7.2 Replacing the Rupture Disk
When the maximum allowable air supply pressure is exceeded, the bursting of the rupture disc
depressurizes the reservoir. The punctured rupture disc must be replaced.
•
Disconnect electrical power.
•
Loosen the reservoir knob
2
and
remove the reservoir lid
1
.
•
Remove the screws and open the
housing.
•
Remove the rupture disc screw.
•
Replace the punctured rupture disc with
a new one.
•
Replace and tighten the rupture disc
screw.
Tightening torque: maximum 20 Nm.
Affix the supplied type plate.
•
Close the housing. Insert and tighten the screws.