16
5 Dispensing
5.2 Filling and Refilling the Product Reservoir
Never fill the product directly into the reservoir!
The pneumatic and safety devices would become clogged and therefore ineffective!
Never completely empty the bottle in the reservoir! The entry of air into the product line
causes problems with dispensing.
When dispensing cyanoacrylate and an empty signal is shown (only 97009), refill the
product reservoir immediately, since air in the product line results in curing of the
product! The dispensing can be further started.
Before loosening the reservoir knobs
2
, the reservoir must be depressurized (pressure-
free)!
The reservoir is depressurized when the depressurizing valve
10
is in position and pressure
gauge
13
indicates no pressure.
•
Loosen the reservoir knobs
2
and
remove the lid
1
.
Product residue on the product
feedline!
Do not contaminate the product
feedline with dust or moisture!
•
Place the lid
1
on the drip funnel.
•
Check that there is no condensed
moisture at the bottle or the sensor
surface.
97009 only:
•
Place the bottle in the bottle-nesting
block
14
.
•
Check that the product bottle inserted in
the bottle-nesting block
14
is pressed
again the level sensor.
•
Insert a full product bottle in the reservoir.
•
Check that the product bottle inserted is pressed against the level sensor.
If there is a gap between the bottle and the sensor, the sensor has to be adjusted.
The adjustment should be done by authorized service personal only, see section 8.
•
Insert the product feedline into the bottle and put on the lid
1
.
•
Uniformly tighten the reservoir knobs
2
by hand.
•
Set the depressurizing valve
10
to position (pressurize).