![Loctite 2182207 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/loctite/2182207/2182207_operating-manual_1933797010.webp)
10
7 Annex
7.1 Spare Parts and Accessories
Description
Order no.
EQ CL32 Mounting Kit ................................................................ 2182206
Radiometer Dosimeter UV LED, UVA and UVB (for 365 nm) ...... 1390323
Radiometer Dosimeter Visible LED, UVV (for 405 nm) ............... 1265282
EQ CL32 Radiometer Adapter (for both meters) ..
……............... 2251337
UV Protection Glasses yellow (for both wavelengths) ................. 1175128
7.2 Error Notifications
When the EQ CL32 LED Spot is examined after an error, the indicator 5 and an acoustic
beep helps to identify the error correctly:
UV LED current error
(e.g. empty battery)
Red, blinking at 1.5 Hz and beeping for 10 seconds
The UV LED switches off.
Over temperature
Red, blinking at 4 Hz and beeping until UV LED temperature
gets back to < 50 °C, at least for 10 seconds. The UV LED
switches off
7.3 Pin Assignment Control Interface
The signals on the M5 control interface are galvanically separated from the internal
electronics using solid-state relays. This enhances the reliability of the product in harsh
industrial environments.
Caution!
Absolute Maximum Ratings!
Parameter
PIN no
Max. rating
LED On / Off
1 and 2
28 V
Active Contact 1/2
3 and 4
26 V, 100 mA
Note!
The potential applied to Status C has to be higher than that on Status Contact -,
otherwise the solid-state relay inside the device can be damaged.