Use for 90 ~180 open hollow metal or solid wooden doors.
Built-in microcontroller. Automatic current output control
according to the door leaf position. The current is being
lowered to 210mA after 6 seconds of door leaf positioning
in order to cut down power consumption and lower the
temperature of the lock body.
Special wearable design. Mechanic life of more than
200,000 times.
Adjustable wiring methods according to the environment.
Adjustable lock time( 0 sec. & 3 sec. ).
1 set of push button control contact is available.
Lock indicator is available for lock status.
Features
SL-166A(B) Dead Bolt Lock Installation Manual
Unit: mm
Accessories
Lock body X 1
5-PIN Connector
M5X25mm X
2
Screws
M4X15mm X
4
Screws
M5X8mm X
4
Screws
M4X8mm X
8
Screws
X2 Shims(small)
For strike plate
X2 Shims(large)
For lock body
Bolt
14mm (Throw) X 12.7mm (Diameter)
Safety Measures
(1)Fail-safe electric lock
(2)Built-in photo couplers door open
push button input contact.
Door will lock again automatically when
door is not open within 6 seconds.
Specifications
Door position reed contact (0.25A@30VDC)
Lock status sensor
Maximum 41
(
)
Room temperature 30
Operation temperature
DC 12V
10%
Power supply
Temperature 0-70
,Humidity85%Rh max
Operation environment
0,3 sec.
( Adjustable)
Delay Time
Mechanic life
More than 200,000 times
Operation current
Standby:210mA
10%;
Operation:570mA
10%
Current and Temperature Chart
Current
(MA)
Time (sec.)
Time (sec.)
Temperature
Start
Stand-by
Door Close
Door Lock
Delay Timer
If delay time of 3 seconds.
Door closed when power is on.
5
60
50
40
30
20
Adjusting before installation
Unscrew the top cover, adjust delay time.
Adjusting automatic lock time:
(Reset after adjusting)
0
SEC.
3
SEC.
1
(Default)
Wiring direction according to the
environment.
3
OR
2
The wires through the
rubber hole
Connections
Attention: There are only 2 screws on the back of the panel.
Push button contact as dry contact. NO voltage input to prevent
damage to the unit.
Current input
Screws
Strike plate X1
Push button input contact
COM.
N.O.
N.C.
Red:
Brown:
Green:
Blue:
Purple:
Yellow:
Door position detection reed is only able to sustain load of
0.25A@30VDC. An external relay is suggested if higher current
to control.
SL-166A has NC and COM contacts
( Environment: Room temperature 30
,
Humidity 60% Rh, DC12V )