Page 2
-
+
AP-10
DC 12V
1A
PUSH BUTTON
RED
READER
BROWN
GREEN
Wiring Diagram
Maximum distance as 6mm.
It is unable to lock if the
spacing is exceeding 6mm.
Attention
Installation
N.O.
COM
N.C.
It is suggested to use an external relay (COM & NC)
if it is exceeding the load of output contact.
-
+
COM
NC
NO
R
Br
P
Blu
Example
Door position detection output
When door is closed, bolt strikes
after delay time count, detection
output is COM and N.O. connected.
Load
External power
Diode
Page 2
The unlock operation temperature of the lock is normally within 41
.
It is considered normal if the temperature is within 41
.
1. Please check power supply (DC-12V)
(600mA current is needed to activate).
.
Please check the power supply.
Continuous locking ( bolt strikes and retracts) when the door is closed.
1. The spacing gap is too wide (>6mm) between the unit and the magnetic panel which is unable to detect
the correct position.
2. Insufficient of current output or malfunction of the power if this event occurred in a sudden when the lock
has been installed for ages.
No operation after installation.
FAQ
The lock is hot.
N.O.
COM
N.C.
(Not available for SL-166A)
When door is not closed, bolt does
not strike, detection output is COM
and N.C. connected.
161
33
28
91
41
141
28
161
Lock Control -
Kouterbaan 63
- 1840 Malderen - Belgium - Tel. +32 52 57 43 02 - [email protected] - www.lockcontrol.be
2. Please check if there is short circuit of the push button contact.
3. Please make sure to place strike plate on the lock and aim the bolt hole with the bolt.
Please make sure the position of the magnet is right before testing the electric lock.