Page  2

-

+

AP-10
DC 12V

  1A

PUSH BUTTON

RED

READER

BROWN

GREEN

 Wiring Diagram

Maximum distance as 6mm.
It is unable to lock if the 
spacing is exceeding 6mm.

Attention

 Installation

N.O.

COM

N.C.

It is suggested to use an external relay (COM &  NC)
if it is exceeding the load of output contact.

-

+

COM

NC

NO

R

Br

P

Blu

Example

 Door position detection output

When door is closed, bolt strikes 
after delay time count, detection
 output is COM and N.O. connected.

Load

External power

Diode

Page  2

The unlock operation temperature of the lock is normally within 41

.

It is considered normal if the temperature is within 41

.

1. Please check power supply (DC-12V) 

(600mA current is needed to activate).

.

Please check the power supply.

Continuous locking ( bolt strikes and retracts) when the door is closed.

1. The spacing gap is too wide (>6mm) between the unit and the magnetic panel which is unable to detect

the correct position.

2. Insufficient of current output or malfunction of the power if this event occurred in a sudden when the lock

has been installed for ages.

No operation after installation.

FAQ

The lock is hot.

N.O.

COM

N.C.

(Not available for SL-166A)

When door is not closed, bolt does 
not strike, detection output is COM 
and N.C. connected.

161

33

28

91

41

141

28

161

Lock Control - 

Kouterbaan 63

 - 1840 Malderen - Belgium - Tel.  +32 52 57 43 02 - [email protected] - www.lockcontrol.be

2. Please check if there is short circuit of the push button contact.
3. Please make sure to place strike plate on the lock and aim the bolt hole with the bolt.

Please make sure the position of the magnet is right before testing the electric lock.