background image

2

Hazard definitions

The following defined terms are used throughout this manual to bring attention to the presence of hazards of various risk levels 
or to important information concerning the life of the product.

 DANGER

 WARNING

 CAUTION

 CAUTION

 NOTICE

DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious 
injury.

WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious 
injury.

CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or 
moderate injury.

CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, if not 
avoided, may result in property damage.

NOTICE indicates special instructions on installation, operation, or maintenance that are important but not 
related to personal injury or property damage.

HAZARD DEFINITIONS

 ....................................................  2

PLEASE READ BEFORE PROCEEDING

 ........................  3

1.  GENERAL INFORMATION

Operating Restrictions ........................................................  4
Tank Shipment...................................................................  4
Components ....................................................................  4-6
Spherical Heat Exchanger.................................................  7

2.  PRE-INSTALLATION

Locating the Tank ...............................................................  8
Recommended Clearances ................................................  8 

3. SOLAR CONNECTIONS

Spherical Pressure Drop Calculations...............................  9
Piping Diagrams ...............................................................  10

4.  DOMESTIC SIDE PIPING

Basic Domestic Piping .....................................................  11
Domestic Water Piping for Distant Fixtures .....................  11
Recirculation Lance ..........................................................  12
Recirculation Lance Pressure Drop Chart .......................  12

Direct Piping to Cold Water Inlet ......................................  13
Multiple Tank Domestic Water Piping ..............................  13
Anti-Scald Mixing Valves ................................................... 13
Domestic Coil Pressure Drop Chart................................ 14
Temperature and Pressure (T&P) Relief Valve .......... 15-16
          Table 4E - Minimum Relief Valve (ASME Rating)  15
Piping Diagrams........................................................... 17-19

5.  BOILER SIDE PIPING

Multiple Tank Connections ...............................................  20
Piping Diagrams ........................................................ 20 - 21

6.  STARTUP AND MAINTENANCE

System Startup .................................................................  22
Maintenance Schedule ................................................ 22-23

     

Winterizing the System ...............................................  23

     

To Drain/Flush the System .........................................  23

7.  PERFORMANCE DATA

Performance Data Charts ........................................... 24-27

REVISION NOTES

 ............................................  Back Cover

Contents

Содержание Strato-Therm+ STU150

Страница 1: ...sed by a qualified heating installer service technician Read all instructions before installing Perform steps in the order given Failure to comply could result in severe personal injury death or subst...

Страница 2: ...ed to personal injury or property damage HAZARD DEFINITIONS 2 PLEASE READ BEFORE PROCEEDING 3 1 GENERAL INFORMATION Operating Restrictions 4 Tank Shipment 4 Components 4 6 Spherical Heat Exchanger 7 2...

Страница 3: ...gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department WARNING NOTICE WARNING WARNING 3 The following chart details...

Страница 4: ...ry if your specific application is not covered in this manual The tank is not intended for use in gravity water heating applications Table 1A Strato Therm Tank Component Materials Component Material T...

Страница 5: ...300 STU257 30 34 1 2 98 83 225 14 5 2875 STU350 36 40 1 2 98 83 325 14 5 3775 STU423 36 40 1 2 115 97 400 16 0 4650 STU504 42 46 1 2 121 103 475 17 0 5475 STU650 48 52 1 2 131 111 625 20 0 7050 STU752...

Страница 6: ...ger Outlet Blue Label Table 1D Tapping Measurements Model A in B in C in D in E in F in G in H in I in O in P in STU150 2 1 4 12 1 4 21 1 4 28 3 4 33 50 3 4 55 1 4 71 76 3 4 3 1 2 3 1 2 STU200 3 1 2 1...

Страница 7: ...l heat exchanger w tank Table 1E Tank with Spherical Measurements Model Spherical Model A in B in STU150 SHX40000 44 1 2 28 STU200 SHX40000 48 1 4 32 STU257 SHX40001 50 1 4 34 STU350 SHX40001 56 1 4 4...

Страница 8: ...led outdoors as it is certified as an indoor appliance and must also be kept vertical on a level surface 2 Table 1C on page 5 shows the weight of all the tanks filled with water Ensure that the locati...

Страница 9: ...sioning must be carried out by a licensed contractor Take appropriate safety measures when carrying out any installation work on the roof and observe all relevant accident prevention regulations It is...

Страница 10: ...URE GAUGE TYPICAL SOLAR PUMP STATION CONTROLLER PRESSURE RELIEF VALVE FILL AND FLUSH VALVE EXPANSION TANK TEMPERATURE GAUGE SPHERICAL HEAT EXCHANGER SOLAR SENSOR IMG00040 Installation Operation Manual...

Страница 11: ...d to allow water to flow in only one direction preventing back flow g Drain required Used to drain the tank for inspection or servicing h Mixing valve required Used to mix hot water with cold water to...

Страница 12: ...ainless steel coil As part of a continuous slow moving loop warm water is circulated directly back into the coil via the lance maintaining tank stratification Reference FIG 4 5 on page 18 for typical...

Страница 13: ...building recirculation system is installed the return water is brought back to the storage tank so as not to disturb the stratification of the Strato Therm Anti scald mixing valves Anti scald valves u...

Страница 14: ...2 8 3 10 7 13 3 14 7 STU200 STU257 STU350 0 1 0 7 1 8 3 2 5 0 7 1 9 5 12 2 15 1 16 7 STU423 0 1 0 8 2 0 3 6 5 6 7 9 10 6 13 6 16 9 18 7 STU504 0 1 0 8 2 1 3 7 5 8 8 2 11 0 14 2 17 7 19 5 STU650 STU75...

Страница 15: ...elief valve must be certified by a nationally recognized testing laboratory that maintains periodic inspection of listed equipment or materials The equipment and materials must meet the requirements f...

Страница 16: ...tly connected to a drain Refer to local codes subject to freezing WARNING Do not install any valve between the relief valve and its connection or on the relief valve discharge piping Improper placemen...

Страница 17: ...cal codes NOTICE IMG00042 SHUTOFF VALVE DOMESTIC HOT WATER CHECK VALVE DOMESTIC COLD WATER RECIRCULATION LINE MIXING VALVE DRAIN CIRCULATION PUMP TEMPERATURE GAUGE SHOCK ARRESTOR BACKUP HEAT SOURCE LO...

Страница 18: ...ired by local codes NOTICE Figure 4 6 Recirculation Piping Flow Over 2 gal min RECIRCULATION LINE CIRCULATION PUMP SHOCK ARRESTOR SHUTOFF VALVE MIXING VALVE TEMPERATURE GAUGE RECIRCULATION LANCE DOMES...

Страница 19: ...ese illustrations are meant to show system piping concept only the installer is responsible for all equipment and detailing required by local codes NOTICE Figure 4 7 Multiple Tank Domestic Piping BUIL...

Страница 20: ...r flow are more balanced throughout each tank To ensure even charging and discharging of each tank it is recommended that only tanks of the same size are placed in the same manifold It is recommended...

Страница 21: ...CHECK VALVE Y STRAINER TYPICAL EXPANSION TANK FILL VALVE PRESSURE RELIEF VALVE AIR SEPARATOR TEMPERATURE GAUGE BACKUP HEAT SOURCE SENSOR Please note that these illustrations are meant to show system p...

Страница 22: ...ter heater immediately Follow the draining instructions and replace the T P relief valve If the T P relief valve weeps periodically it may be due to thermal expansion Do not plug the T P relief valve...

Страница 23: ...Installation of a Temperature Pressure T P relief valve is required Owner monthly maintenance to include Visually check valves pipes and fittings for leaks Call a qualified service technician to repa...

Страница 24: ...gpm First Hour Rating gal hr STU150 16 1035 23 1516 15 997 STU200 19 1244 27 1774 18 1125 STU257 19 1365 27 1965 18 1250 STU350 19 1550 27 2223 18 1395 STU423 27 1690 36 2451 26 1600 STU504 28 1816 3...

Страница 25: ...5 507 555 507 555 507 555 507 555 507 555 507 555 507 555 18 1080 537 411 537 411 537 411 537 411 537 411 537 411 537 411 537 411 537 411 19 1140 567 267 567 267 567 267 567 267 567 267 567 267 567 26...

Страница 26: ...8 528 548 528 548 528 548 528 548 528 548 528 548 528 548 528 548 528 14 840 590 722 590 722 590 722 590 722 590 722 590 722 590 722 590 722 590 722 15 900 632 917 632 917 632 917 632 917 632 917 632...

Страница 27: ...328 418 328 418 12 720 358 274 358 274 358 274 358 274 358 274 358 274 358 274 358 274 358 274 13 780 388 130 388 130 388 130 388 130 388 130 388 130 388 130 388 130 388 130 14 840 417 986 417 986 41...

Страница 28: ...Revision Notes Revision A ECO C09107 initial release STU I O Rev A 10 11 Printed in U S A...