User’s Information Manual 

Please read before proceeding

The Knight Wall Mount Installation and 
Operation Manual along with the Knight 
Wall Mount Service Manual are for use 
only by a qualified heating installer/service 
technician.  Refer only to this User’s 
Information Manual for your reference.  
Improper installation, adjustment, 
alteration, service or maintenance can 
cause property damage, personal injury 
(exposure to hazardous materials) or loss 
of life.  Installation and service must be 
performed by a qualified installer, service 
agency or the gas supplier (who must 
read and follow the supplied instruction 
before installing, servicing, or removing 
this boiler.  This boiler contains materials 
that have been identified as carcinogenic, 
or possibly carcinogenic, to humans).

Failure to adhere to the guidelines on this 
page can result in severe personal injury, 
death, or substantial property damage.

Boiler service and maintenance –

• To avoid electric shock, disconnect electrical supply 
  before performing maintenance.

• To avoid severe burns, allow boiler to cool before 
 performing 

maintenance.

Boiler operation –

• Do not block flow of combustion or ventilation air to 
  the boiler.  This boiler is equipped with a control which 
  will automatically shut down the boiler should air or 
  vent be blocked.  If vent or air blockage is easily 
  accessible and removable, remove it.  The boiler should 
  attempt to restart.  If blockage is not obvious or cannot 
  be removed, have the boiler and system checked by a 
  qualified service technician.

• Should overheating occur or gas supply fail to shut off, 
  do not turn off or disconnect electrical supply to the 
  circulator.  Instead, shut off the gas supply at a location 
  external to the appliance.

• Do not use this boiler if any part has been under water.  
  The possible damage to a flooded appliance can be 
  extensive and present numerous safety hazards.  Any 
  appliance that has been under water must be replaced.

Boiler water –

• Thoroughly flush the system (without boiler 
 

connected) to remove sediment.  The high-efficiency 

  heat exchanger can be damaged by build-up or 
 

corrosion due to sediment.

• Do not use petroleum-based cleaning or sealing 
  compounds in the boiler system.  Gaskets and seals in 
  the system may be damaged.  This can result in 
  substantial property damage.

• Do not use “homemade cures” or “boiler patent 
  medicines”.  Serious damage to the boiler, personnel, 
  and/or property may result.

• Continual fresh make-up water will reduce boiler life.  
  Mineral buildup in the heat exchanger reduces heat 
  transfer, overheats the stainless steel heat exchanger, 
  and causes failure.  Addition of oxygen carried in by 
  makeup water can cause internal corrosion.  Leaks in 
  boiler or piping must be repaired at once to prevent 
 makeup water.

Freeze protection fluids –

• NEVER use automotive antifreeze.  Use only inhibited 
 propylene glycol solutions, which are specifically 
  formulated for hydronic systems.  Ethylene glycol is 
  toxic and can attack gaskets and seals used in hydronic 
 systems.

When calling or writing about the boiler 
– Please have the boiler model and serial 
number from the boiler rating plate.

Consider piping and installation when 
determining boiler location.

Any claims for damage or shortage in 
shipment must be filed immediately 
against the transportation company by 
the consignee.

Factory warranty (shipped with unit) does 
not apply to units improperly installed or 
improperly operated.

3

 NOTICE

 WARNING

 NOTICE

Содержание Knight 211

Страница 1: ...likely to be present WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a near...

Страница 2: ...lt in property damage NOTICE indicates special instructions on installation operation or maintenance that are important but not related to personal injury or property damage Contents HAZARD DEFINITION...

Страница 3: ...ical supply to the circulator Instead shut off the gas supply at a location external to the appliance Do not use this boiler if any part has been under water The possible damage to a flooded appliance...

Страница 4: ...hments Swimming pools Metal fabrication plants Beauty shops Refrigeration repair shops Photo processing plants Auto body shops Plastic manufacturing plants Furniture refinishing areas and establishmen...

Страница 5: ...54 F above return water temperature If combustion or performance indicate need Clean heat exchanger Remove and clean burner using compressed air only Clean the blower wheel Owner maintenance see page...

Страница 6: ...ntaminate the boiler intake air will cause acidic condensate in the boiler This will cause significant damage to the boiler if allowed to continue Read the list of potential materials listed in Table...

Страница 7: ...nstalled in the unit open this is needed as a vacuum break The blocked drain switch will shut the boiler down before any condensate can flow out of the tee Use materials approved by the authority havi...

Страница 8: ...t the lever completely the valve or discharge line may be blocked Immediately shut down the boiler following the operating instructions on page 9 of this manual Call your qualified service technician...

Страница 9: ...User s Information Manual 9 3 Operating instructions o C...

Страница 10: ...s the RIGHT SELECT HOME key again to store the new settings and return to the Status Screen Please note that the brackets denote screen status NOTICE Adjusting parameters CAUTION Before changing param...

Страница 11: ...disappear Press the HOME key to save these skipped triggers If you selected any currently active trigger s the current Night Setback will be cancelled There are three 3 individual user set points for...

Страница 12: ...for an additional 10 seconds to clear the combustion chamber and vent system of residual flue products SHUTDOWN The unit has been placed in the OFF position The controlled temperature has exceeded it...

Страница 13: ...The status of the DHW pump output BMS VOLTAGE The voltage received from a BMS system BLR PUMP OUTPUT The speed signal sent to a variable speed boiler pump in percent SYS PUMP INPUT The speed signal r...

Страница 14: ...g indicated by the cursor Pressing the NAVIGATION dial will display the Set Points Screen Turning the NAVIGATION dial will move the cursor up or down Turning the NAVIGATION dial will increase or decre...

Страница 15: ...15 Notes User s Information Manual...

Страница 16: ...odel numbers for the Knight Wall Mount upgrade Revision B ECO C07072 reflects the change in design of the manual air vent the update of FIG 2 3 on page 8 and the reorganization of the information on p...

Отзывы: