background image

                

User’s Information Manual

10

4  

SMART SYSTEM control module

Figure 4-1 Control Panel

Knight wall mount control module

Use the control panel (FIG. 4-1) to set temperatures, operating conditions, and monitor boiler operation.

NAVIGATION DIAL

The information on the bottom of the display shows the functions of the two SELECT keys (on either corner), and the 
NAVIGATION dial (in the center):  MENU = Left SELECT Key
                                                          SETPOINTS = NAVIGATION Dial - Pressing Down
                                                          SHDN = Right SELECT Key  

Access modes

User

The user can adjust space heating and tank target temperatures 
by pressing the NAVIGATION dial when “

SETPOINTS” is 

flashing at the bottom of the display.  The user can adjust the 
date and time, temperature units, and night setback override 
(if active) by pressing the LEFT SELECT [MENU] key for 5 
seconds. When the user password “0000” appears, then press 
the RIGHT SELECT [SAVE] key (do not change the password).

Installer

Most parameters are available only to the installer, accessible 
only by entering the installer password, see the Knight Boiler 
Service Manual.

Saving parameters 

Press the RIGHT SELECT [SAVE] key one time to return to the 
parameter listing.  Press the RIGHT SELECT [HOME] key again 
to store the new settings and return to the Status Screen.

Please note that the brackets ([]) denote 
screen status.

 NOTICE

Adjusting parameters

 

CAUTION

Before changing parameters, note the 
settings so that the unit can be returned to 
its original operating parameters.

The control uses an internal clock for the night setback feature 
and for logging of events.  For these features to work properly, 
the clock must be set when the boiler is first installed or any 
time the boiler has been powered off for more than four (4) 
hours.  This parameter must be accessed to set the clock.  

 NOTICE

The internal clock does not adjust for 
Daylight Savings Time and therefore, 
will require a manual adjustment.

To set the clock, access the clock menu as described in the 

User

 section.  Rotate the NAVIGATION dial (if needed) until 

the arrow (>) is pointing to “TIME & DATE”.  Press the 
NAVIGATION dial once.  If the date and time are incorrect, 
press the NAVIGATION dial again.  The hours value will 
begin flashing.  Rotate the NAVIGATION dial until the hour 
and AM/PM values are correct.  Press the NAVIGATION 
dial again.  The minutes value will begin flashing.  Rotate 
the NAVIGATION dial to adjust the minutes.  Repeat this 
procedure to adjust the month, date and year.  Save the 
new settings as described in the 

Saving Parameters

 section 

(this page).

Содержание Knight 211

Страница 1: ...likely to be present WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a near...

Страница 2: ...lt in property damage NOTICE indicates special instructions on installation operation or maintenance that are important but not related to personal injury or property damage Contents HAZARD DEFINITION...

Страница 3: ...ical supply to the circulator Instead shut off the gas supply at a location external to the appliance Do not use this boiler if any part has been under water The possible damage to a flooded appliance...

Страница 4: ...hments Swimming pools Metal fabrication plants Beauty shops Refrigeration repair shops Photo processing plants Auto body shops Plastic manufacturing plants Furniture refinishing areas and establishmen...

Страница 5: ...54 F above return water temperature If combustion or performance indicate need Clean heat exchanger Remove and clean burner using compressed air only Clean the blower wheel Owner maintenance see page...

Страница 6: ...ntaminate the boiler intake air will cause acidic condensate in the boiler This will cause significant damage to the boiler if allowed to continue Read the list of potential materials listed in Table...

Страница 7: ...nstalled in the unit open this is needed as a vacuum break The blocked drain switch will shut the boiler down before any condensate can flow out of the tee Use materials approved by the authority havi...

Страница 8: ...t the lever completely the valve or discharge line may be blocked Immediately shut down the boiler following the operating instructions on page 9 of this manual Call your qualified service technician...

Страница 9: ...User s Information Manual 9 3 Operating instructions o C...

Страница 10: ...s the RIGHT SELECT HOME key again to store the new settings and return to the Status Screen Please note that the brackets denote screen status NOTICE Adjusting parameters CAUTION Before changing param...

Страница 11: ...disappear Press the HOME key to save these skipped triggers If you selected any currently active trigger s the current Night Setback will be cancelled There are three 3 individual user set points for...

Страница 12: ...for an additional 10 seconds to clear the combustion chamber and vent system of residual flue products SHUTDOWN The unit has been placed in the OFF position The controlled temperature has exceeded it...

Страница 13: ...The status of the DHW pump output BMS VOLTAGE The voltage received from a BMS system BLR PUMP OUTPUT The speed signal sent to a variable speed boiler pump in percent SYS PUMP INPUT The speed signal r...

Страница 14: ...g indicated by the cursor Pressing the NAVIGATION dial will display the Set Points Screen Turning the NAVIGATION dial will move the cursor up or down Turning the NAVIGATION dial will increase or decre...

Страница 15: ...15 Notes User s Information Manual...

Страница 16: ...odel numbers for the Knight Wall Mount upgrade Revision B ECO C07072 reflects the change in design of the manual air vent the update of FIG 2 3 on page 8 and the reorganization of the information on p...

Отзывы: