8
Status of the water
heater
8.1
Introduction
Topics covered in this chapter, in sequence:
•
Operating modes
;
•
Power Anode status
;
•
Error conditions
.
8.2
Operating modes
When running, the appliance has three basic
operating modes, namely:
•
ISOLATED
In this mode the appliance is off and all
components are electrically dead.
-
The isolator (switch between the appliance
and the power supply) is turned off.
-
On the control panel, the on/off switch is at
position 0
.
•
OFF
In this mode, the frost protection is activated.
-
The isolator is set to position I.
-
On the control panel, the on/off switch is at
position 0
.
•
ON
In this mode the appliance continuously fulfils
demand.
On the control panel:
-
the on/off switch is in
position I
-
The water temperature can be set using the
rotary button on the control
thermostat
(7.5 "Control thermostat")
.
8.3
Power Anode status
If the appliance is fitted with a Power Anode, there is
an extra indicator lamp on the operating panel.
Depending on the status of the appliance, this lamp
will be lit either green or red, or it will be off:
•
Green
This state indicates that the Power Anode is
working correctly.
•
Red
This state indicates an error, and the Power Anode
is not working.
•
Off
This state indicates that the Power Anode is not
working.
Note
If there is an error with the Power Anode (red), or if
the Power Anode is not working (off), this will have no
effect on the hot water supply.
8.4
Error conditions
If the appliance has an error, heat demand will be
(temporarily) ignored. There are various types of
errors, divided into three groups:
•
Gas control lockout errors
In this case the gas control's safety valve is closed,
as a result of which the pilot flame is extinguished.
Once this error has been rectified, the pilot flame
must be re-lit
(9.2 "Starting the appliance")
.
•
Blocking errors
In this case the gas control's main valve is closed.
Despite a possible demand, combustion is
stopped although the pilot flame remains ignited.
These conditions disappear automatically once
the cause of the error has been eliminated. The
appliance then starts running again
spontaneously.
•
Lockout error from the flue gas thermostat
This error condition has much the same
characteristics as a 'Blocking error'. The difference
here is that the lockout (push button) for the flue
gas thermostat in the draught diverter is
activated
(7.5 "Control thermostat")
. After
removing the cause, the push button must be
pressed to re-start the appliance.
The cause of the error cannot be seen on the control
panel. For a detailed overview of error conditions,
please refer to the 'Errors
(11 "Errors")
'.
If you as an end user come across the appliance when
it is in an error status, you can attempt to start the
device up
(9.2 "Starting the appliance")
.
However, if the error returns or occurs several times in
a short time, you must contact your service and
maintenance engineer.
Содержание CH 100 CE
Страница 4: ...4 Instruction manual CH gis...
Страница 10: ...Introduction 10 Instruction manual CH 1 gis...
Страница 16: ...Working principle of the water heater 16 Instruction manual CH 2 gis...
Страница 36: ...Conversion to a different gas category 36 Instruction manual CH 4 is...
Страница 44: ...Status of the water heater 44 Instruction manual CH 8 gis...
Страница 46: ...Starting the water heater 46 Instruction manual CH 9 gis...
Страница 48: ...Shutting down 48 Instruction manual CH 10 gis...
Страница 60: ...Electrical diagram 60 Instruction manual CH 14 is 1 brown 2 blue 3 yellow green 4 black 5 white 0305906 R0...
Страница 62: ...Electrical diagram 62 Instruction manual CH 14 is...
Страница 64: ...Declaration of Conformity 64 Instruction manual CH 15 is...
Страница 66: ...0310 570 1 0 UK Index Instruction manual CH...