21 Error Messages
41
21 Error Messages
Lift Speed Changed?
For accurate measurement, the speed of raising the lift arms must be smooth,
without acceleration or deceleration.
The LR810 can detect changing speed as the arms go past the trigger point.
If this occurs, the indicator displays the following error message.
Depending on the installation of the LR810, there are two possibilities:
1.
No weight is displayed and hence there is no weight to add.
You should repeat the lift. Avoid accelerating and decelerating at or
near the trigger sequence.
2.
If weighing error is turned “off” and a weight is displayed.
You can add the weight to the running total (bearing in mind that the
weight measurement is not reliable) or you can ignore this weight and
repeat the lift again avoiding acceleration and deceleration at or near
the trigger sequence.
Bouncing Load
If the lift arms are bouncing significantly while weighing, an error occurs.
This can happen if, for example, the loader is driven over uneven ground
while lifting the load.
The LR810 can detect a bouncing load and if this occurs, the indicator
displays the following message.
No weight is displayed and hence there is no weight to add.
Содержание LR810
Страница 1: ...LR810 WEIGHING SYSTEM Operating Manual ...
Страница 4: ......
Страница 50: ...22 Keys 44 MENU Displays the operator menu options Number keys ...