Safety
Indicates the status of the Safety Interlock circuitry.
The “On”
state indicates that all sensor light sources are active
Encoder A
Encoder alarm:
The encoder alarm is turned on when one of the encoder’s
differential voltage signals (A, B or Z) fall below 0.475 volts
Encoder F
On continuously: Forward motion with no indexing is
detected
Blinking: Forward motion with indexing is detected
Encoder R
On continuously: Reverse motion with no indexing is
detected
Blinking: Reverse motion with indexing is detected
In 1
Digital input port 1 active
In 2
Digital input port 2 active
In 3
Digital input port 3 active
In 4
Digital input port 4 active
Out 1
Digital output port 1 active
Out 2
Digital output port 2 active
Sensor Port Green LED
On: Power over Ethernet device detected and powered
Blinking: Error
Sensor Port Yellow LED
Unused
5.6.4 Terminal plugs
The Master uses four Phoenix Contact (MC 1.5/ series) terminal plugs:
Power and Safety interface
Encoder interface
Digital I/O interface
External Sync interface
Power and Safety (6-pin connector)
Pin
Signal
1
+48VDC