4.2.3 Safety Interlock on Master 1200/2400
The Safety Interlock signal allows the user to turn on and off all light sources in the
sensors without disrupting power to the system. The laser safety control signal must be
provided at the Master for the sensors to properly function.
To enable the laser safety control signal, apply b12V and +48V across the laser
/- connection.
4.2.4 Sensors, Master 1200/2400 and Station to Gigabit Switch
The Gigabit switch connects all the sensor data lines with the Master and the Station.
Each sensor in the system connects to the Gigabit Switch with the yellow jacketed RJ45
cable end of the sensor Network Cordset.
The Master 1200/2400 connects to the Gigabit Switch via the “Link” port on the Master.
The Station
connects via its “IN” port to the Network Switch.
4.2.5 Client computer
The Client computer is connected to the Station
’s “OUT” Gigabit Ethernet adapter.
Содержание chroma+scan 24 0 Series
Страница 1: ...chroma scan 24x0 Version 5 4 5 4...
Страница 26: ...5 8 Dimensions Mounting 5 8 1 chroma scan 2420...
Страница 27: ......
Страница 28: ...5 8 2 chroma scan 2440...
Страница 29: ......
Страница 30: ...6 4 482 6 444 5 130 5 121 44 5 8 3 Master 2400 Dimensions are in millimeters mm...