Installation:
Installation must be carried out only by authorised, licensed installers in accordance with these instructions,
local gas
fi
tting regulations, local building codes, the Gas Installation Code AS/NZS5601 and any other
relevant statutory regulations.
Unpacking:
Remove the packaging.
Carefully remove the protective
fi
lm from metal surfaces. (If any)
Remove any traces of glue using a suitable solvent.
Upon Delivery
Immediately check for any damage caused during transport.
Inspect the packs before and after unloading.
The forwarder is responsible for the safety of the goods during transport and delivery.
Notify the forwarder in the event of apparent or hidden damage. Specify any damage or shortages on dispatch
note.
Keep all documentation contained in the packing.
Positioning:
The installation diagrams give the overall dimensions of the appliances and the positions of connections
(gas, electricity and water)
Appliances can be installed separately or in combination with other appliances in the same range.
Leave at least 150mm between the appliance and the side walls. Only if side walls are made from non-
combustible material, appliance can be installed next to the wall.
When positioned under a ventilation canopy, the appliance must have at least 1200mm between the top of
the appliance and the bottom edge of the canopy
Maintain an adequate distance between the appliance and any combustible walls.
Leave an adequate distance between the appliance and any side walls in order to allow subsequent servicing
or maintenance operations.
Suitably insulate any surfaces that are less than the speci
fi
ed distances from the appliance.
Use:
Our appliances offer high performance and ef
fi
ciency. To reduce consumption of gas, do not use appliance
when burner section is empty or in conditions that compromise its optimal ef
fi
ciency.
Exhaust:
The appliance must be installed under a ventilation exhaust system complying with the local building
regulations and AS/NZS5601 – Gas Installation code.
Place the appliance under the extractor hood to ensure removal of fumes and steam produced by cooking.
The correct clearance between the burner / appliance outlet and the exhaust hood must comply with the
current standards and be not less than 1350mm.
Where there is no exhaust hood, contact local authority for information and guidance on installation.
Size:
Diemension Width (mm)
Depth (mm)
Height (mm)
LKK-1BSP, 1BCSP & 1BMSP
600
730
520
LKK-2BSP, 2BCSP & 2BMSP
1200
730
520
LKK-3BSP & 2BCSP & 3BMSP
1800
730
520
Installation & Operation Specifications