LKK LKK-1BCSP Скачать руководство пользователя страница 4

• Speci

fi

 cations and design are subject to change without notice • Pictures are for illustrative purposes only • 2017 November

4

P: (+64) 9 8372960  F: (+64) 09 836 9168
18 Paramount Drive, Henderson, Auckland
www.lkk.co.nz  

[email protected]

P: 1300 655 715  

F: (+61) 02 8587 0033

47 George St, Clyde Sydney, NSW 2142, Sydney
www.lkk.com.au  

[email protected]

LKK Commercial Gas Stockpot Models:

  

LKK-1BSP 

LKK-1BCSP 

LKK-1BMSP

  

LKK-2BSP 

LKK-2BCSP 

LKK-2BMSP

  

LKK-3BSP 

LKK-3BCSP 

LKK-3BMSP 

 

• Models not listed above, refer to IAPMO product listing directory GMK10452

INSTALLATION AND OPERATION INSTRUCTION

Read this manual carefully before using the appliance.

Keep the manual for future consultation after installation.
This manual contains information regarding LKK’s commercial gas stockpots.

See the appliance data plate positioned on the front control panel in order to identify the appliance product 
code.

Only install the appliance in a well ventilated place. Inadequate ventilation causes asphyxia. Do not obstruct
the ventilation system in the place where the appliance is installed. Do not obstruct the vents or ducts of this
or other appliances.

Installation, maintenance and conversion to other gas types must only be carried out only by an authorised 
person(s). For after sales assistance, contact an authorised service agent or the supplier for spare parts.

This appliance is designed for cooking foodstuffs. It is intended for commercial use only. Any other use is to be
considered improper.

This appliance is suitable to be used without the water function.

Personnel using the appliance must be trained. Do not leave the appliance unattended when it is in operation.

Turn off the appliance in case of fault or poor operation.

Do not use products (even diluted) containing chlorine (sodium hypochlorite, hydrochloric or muriatic acid, etc) 
to clean the appliance.

DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION.

DO NOT STORE FLAMMABLE MATERIALS ON OR NEAR THIS APPLIANCE.

Do not use metal tools to clean steel parts (wire brushes or Scotch Brite type scouring pads).

Do not allow dirt, fat, food or other to form deposits on the appliance.

Do not clean the appliance with direct jets of water.

Clean the appliance everyday after use.

Failure to comply with the above instructions can compromise the safety of the appliance.

It is recommended the appliance be cleaned daily, checked for correct operation on at regular intervals and be 
serviced every 12 months by an authorised service person.

Installation & Operation Specifications

Содержание LKK-1BCSP

Страница 1: ...al GMK10452 P 64 09 837 2960 F 64 09 836 9168 18 Paramount Drive Henderson Auckland www lkk co nz sales lkk co nz P 1300 655 715 F 61 02 8587 0033 47 George St Clyde Sydney NSW 2142 Sydney www lkk com...

Страница 2: ...land www lkk co nz sales lkk co nz P 1300 655 715 F 61 02 8587 0033 47 George St Clyde Sydney NSW 2142 Sydney www lkk com au sales lkk com au Specifications and design are subject to change without no...

Страница 3: ...ange without notice Pictures are for illustrative purposes only 2017 November 3 Installation Operation Specifications 4 Nominal Gas Consumption Pressure 7 Connection Points 8 Installation Instruction...

Страница 4: ...o other gas types must only be carried out only by an authorised person s For after sales assistance contact an authorised service agent or the supplier for spare parts This appliance is designed for...

Страница 5: ...in the same range Leave at least 150mm between the appliance and the side walls Only if side walls are made from non combustible material appliance can be installed next to the wall When positioned u...

Страница 6: ...s do not apply where an adjacent surface is of a non combustible material or is combustible but is protected with fire resistant material in accordance with Appendix C The fire resistant material may...

Страница 7: ...ressure Kpa LKK 1BSP 115 18 x 1 35 1 00 LKK 1BCSP 95 24 x 0 95 0 90 LKK 1BMSP 140 32 x 1 10 1 00 LKK 2BSP 230 36 x 1 35 1 00 LKK 2BCSP 190 48 x 0 95 0 90 LKK 2BMSP 280 64 x 1 10 1 00 LKK 3BSP 345 54 x...

Страница 8: ...nections Refer to appliance data plate for information relating to gas consumption pressures See table below to work out where the gas inlet for each model Gas inlet for all model high models is 270mm...

Страница 9: ...m and be kept as short as possible A chain must be fitted to restrict the appliance movement to no more than 80 of the hose length Appliance Gas Regulator An appliance gas pressure regulator must be f...

Страница 10: ...lame hold button in for at least 20 sec on new installations you may have to hold the button longer to allow air in pipes to purge out for several minutes Turn the main burner on by moving lever to ON...

Страница 11: ...e em em m e e e e e e e em e e e e e e em e em mov ov ov ov o ov ov ov ov ov ov ov v o ov ov ov ov v ov ov o o ov ov ov ov ov ov ov ov o o ov ov ov o ov ov ov ov o ov v o ov o o o ov ov o o ov o ov ov...

Страница 12: ...is consistant to appliance and there is no sign of kink See below example If unit is showing any signs of the below problems follow steps accordingly 1 Pilot light won t stay lit a If flame is too sm...

Страница 13: ...thout notice Pictures are for illustrative purposes only 2017 November 13 Troubleshoot Pilot Cover Installation Duckbill burner without pilot cover Chimney burner without pilot cover Duckbill burner w...

Страница 14: ...v iv ve er er e er er er er er er er er er er er er r e er r r r er er e e er e e to to t to to t t t to to to to to to to o t to to to o t t to a a a a a a a a a a a a a a a a adj dj dj dj dj dj dj...

Страница 15: ...nd turn anti clock wise Once loosened you may use hand to unscrew out The nozzle will look like the above once taken out How to Remove Duckbill Injector How to Clean Duckbill Nozzle 1 Remove the greas...

Страница 16: ...installation instructions provided with the appliance LKK has the right to determine whether or not a fault is caused by faulty workmanship or material or that any parts are defective Defective part s...

Страница 17: ...this appliance be serviced every 6 months by authorised service technician All normal care should be taken in up keep of gas equipment make sure burners and gas cocks are cleaned after heavy daily use...

Страница 18: ...res are for illustrative purposes only 2017 November 18 P 64 9 8372960 F 64 09 836 9168 18 Paramount Drive Henderson Auckland www lkk co nz sales lkk co nz P 1300 655 715 F 61 02 8587 0033 47 George S...

Страница 19: ...res are for illustrative purposes only 2017 November 19 P 64 9 8372960 F 64 09 836 9168 18 Paramount Drive Henderson Auckland www lkk co nz sales lkk co nz P 1300 655 715 F 61 02 8587 0033 47 George S...

Страница 20: ...837 2960 Fax 64 09 836 9168 Head Office 18 Paramount Drive Henderson Auckland www lkk co nz sales lkk co nz Australia Phone 1300 655 715 Fax 61 02 8587 0033 47 George St Clyde NSW 2142 Sydney www lkk...

Отзывы: