background image

1

INTRODUCTION

EN

This instruction sheet provides you with the information required 
to safely own and operate your Little Giant pump. Retain these 
instructions for future reference.
The Little Giant pump you have purchased is of the highest quality 
workmanship and material, and has been engineered to give you 
long and reliable service. Little Giant pumps are carefully tested, 
inspected, and packaged to ensure safe delivery and operation. 
Please examine your pump carefully to ensure that no damage 
occurred during shipment. If damage has occurred, please 
contact the place of purchase. They will assist you in replacement 
or repair, if required.

READ THESE INSTRUCTIONS CAREFULLY BEFORE 
ATTEMPTING TO INSTALL, OPERATE, OR SERVICE YOUR 
LITTLE GIANT PUMP. KNOW THE PUMP’S APPLICATION, 
LIMITATIONS, AND POTENTIAL HAZARDS. PROTECT 
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY 
INFORMATION. FAILURE TO COMPLY WITH THESE 
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/
OR PROPERTY DAMAGE!

DESCRIPTION

This pump has been designed to operate in applications such 
as waterfalls, streams, and fountainheads. It can also be used to 
circulate the water in your pond. Unique features of this pump 
line include a non-clogging vortex impeller, auto-resetting thermal 
overload protection, stainless steel motor housing, and the ability 
to pass solids with diameters up to .39”/10mm (WGFP-15) or 
.98”/25mm (WGFP-33). CAUTION: To prevent damaging the 
pump, do not pump abrasives such as sand or mud.

SAFETY GUIDELINES

Read all instructions and Safety Guidelines thoroughly. Failure to 
follow the guidelines and instructions could result in serious bodily 
injury and/or property damage.
RISK OF ELECTRICAL SHOCK: This pump is supplied with a 
grounding conductor and grounding-type attachment plug. To 
reduce the risk of electric shock, be certain that it is connected 
only to a properly grounded, grounding-type receptacle. A 
separate branch circuit is recommended. Do not remove the third 
prong from the plug. 

RISK OF ELECTRICAL SHOCK: This pump has not been certified 
for use in swimming pool areas where people are present in the 
water. Do not use the pump for this purpose.
WARNING: Do not use to pump flammable or explosive fluids such 
as gasoline, fuel oil, kerosene, etc. Pump should only be used 
with liquids compatible with pump component materials. Failure 
to follow this warning can result in property damage, personal 
injury, or death.
The pump motor is equipped with an automatic resetting thermal 
protector and may restart unexpectedly.
Do not handle a pump or pump motor with wet hands or when 
standing on a wet or damp surface, or in water. Do not stand 
in water while changing fuses or insert your finger into the fuse 
socket.
Make certain the unit is disconnected from the power source, all 
liquids are drained, and all pressure released within the system 
before attempting to service the pump.
This pump has no user-serviceable parts. The motor housing of the 
pump is completely sealed and requires no service. Disassembly 
of the motor housing or alteration of the power cord will void all 
warranties. The power cord on these units cannot be replaced.
Conformity with local and state electric codes is mandatory. 
The National Electric Code requires that a ground fault circuit 
interrupter (GFCI) be used in the branch circuit supplying sump, 
utility, effluent and all fountain pumps, pool pumps and other pond 
equipment.
All wiring and electrical work should be done by a qualified 
electrician.
Secure the discharge line before starting the pump. An unsecured 
discharge line will whip, possibly causing personal injury and/or 
property damage.
Do not run the pump dry. It is designed to be cooled by the fluid it 
moves. If the pump is run dry it will become dangerously hot, and 
could cause personal injury and/or damage to the pump.
The pump’s motor housing contains a dielectric oil to aid in 
bearing lubrication and motor heat dissipation. This oil is non-toxic 
to aquatic life. However, suffocation can occur if oil is left on the 
water surface. If oil escapes the motor housing it can be removed 
from the surface quickly by placing newspapers on the water 
surface to soak up the oil.
Do not lift or carry the pump by grasping of the power cord. 
A handle is molded integral with top housing cover for this 
purpose.

ELECTRICAL CONNECTIONS

 1.  Check the pump label for proper voltage required. Do not 

connect the pump to any voltage other than that shown.

 2.  Plug the power cord directly into an electrical outlet.

MODELS

 WGFP-15 • WGFP-33

115V/60HZ

Franklin Electric Co., Inc.

P. O. Box 12010

Oklahoma City, OK 73157-2010

405.947.2511 • Fax: 405.947.8720

www.LittleGiantPump.com

[email protected]

MODEL

NO.

CATALOG 

NO.

SAFETY 

LISTING

DISCH.

SIZE

HP PH VOLTS HZ AMPS WATTS MOTOR 

TYPE

GPH @ HEAD

SHUT 

OFF

POWER 

CORD

WEIGHT 

(lbs.)

5’

10’

15’

20’

WGFP-15

566066

cCSAus

1-1/4” 

FNPT

1/5

1

115

60

4

355

PSC

2300 1700 807

127

21’

19’

15.2

WGFP-33

566067

cCSAus

1-1/2” 

FNPT

1/3

1

115

60

5

455

PSC

2500 2000 1400 600

25’

19’

17.5

Table 1 • Tableau 1 • Tabla 1

Содержание WGFP-15

Страница 1: ...eath The pump motor is equipped with an automatic resetting thermal protector and may restart unexpectedly Do not handle a pump or pump motor with wet hands or when standing on a wet or damp surface o...

Страница 2: ...OMMAGES MAT RIELS DESCRIPTION Cette pompe a t con ue pour fonctionner dans des applications comme des chutes d eau des ruisseaux et des t tes de fontaines Elle peut galement tre utilis e pour faire ci...

Страница 3: ...vacuation s ouvre Desconecte el cable de energ a Elimine el aire sumergiendo la bomba en posici n inclinada y agit ndola con la descarga abierta Suction screen clogged La grille d aspiration est bouch...

Страница 4: ...UCCI N ES Esta hoja de instrucciones le proporciona la informaci n requerida para tener y operar de forma segura su producto Little Giant Guarde las instrucciones para referencia futura El producto Li...

Страница 5: ...t dise ada para bombear agua nicamente con una temperatura m xima de 40 C 105 F No bombee l quidos calientes El uso ideal de esta bomba es el bombeo de agua dulce mientras est sumergida para un debido...

Страница 6: ...he above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state and country to country The Natio...

Страница 7: ...reemplazo de la bomba el distribuidor o vendedor debe separar los art culos y retenerlos para que sean inspeccionados por un representante de Little Giant o avisarle a la f brica de los detalles del...

Страница 8: ...istance please contact 1 888 956 0000 Pour des parties ou la r paration entrez s il vous pla t en contact 1 888 572 9933 Pour l aide technique entrez s il vous pla t en contact 1 888 956 0000 Para par...