This submersible multi-purpose pump is designed for water transfer 
applications and household water removal. This pump is for use  
with WATER ONLY. 
This pump is:

•  NOT FOR USE FOR TRANSFERRING POTABLE WATER.
•  NOT FOR USE IN EFFLUENT OR SEWAGE APPLICATIONS!
•  NOT TO BE INSTALLED IN LOCATIONS CLASSIFIED AS HAZARDOUS IN 

ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE (ANSI/NFPA)!

•  NOT FOR USE AS A POND PUMP!
•  NOT FOR USE WITH SPRINKLER SYSTEMS as this pump does not 

deliver enough pressure for sprinkler applications.

This instruction sheet provides you with the information required to 
safely own and operate your product. Retain these instructions for 
future reference. The product you have purchased is of the highest 
quality workmanship and material and has been engineered to give 
you long and reliable service. This product has been carefully tested, 
inspected, and packaged to ensure safe delivery and operation. Please 
examine your item(s) carefully to ensure that no damage occurred 
during shipment. If damage has occurred, please contact the place of 
purchase. They will assist you in replacement or repair, if required.

SAFETY GUIDELINES

s

!

DANGER

 Do not touch the motor, hoses or 

water until unit is unplugged or shut off at the breaker. If the circuit 
breaker is not accessible, call the electric company to shut off service 
to the house, or call your local fire department for instructions. 
Failure to follow this warning can result in fatal electrical shock.

s

!

WARNING

 

RISK OF ELECTRIC SHOCK 

This product is supplied with a grounding conductor and grounding-
type attachment plug. To reduce risk of electric shock, be certain 
that it is connected only to a properly grounded grounding-type 
receptacle. The third prong is to ground the pump to help to  
prevent possible electric shock hazard. Do not remove the  
third prong from the plug.

As a safety measure, each electrical outlet should be checked with an 
Underwriters Laboratory Listed circuit analyzer. This will indicate if the 
power, neutral and ground wires are properly connected. If they are 
not, call a qualified licensed electrician.

s

!

WARNING

 

RISK OF ELECTRIC SHOCK AND FIRE 

HAZARD. DO NOT USE AN EXTENSION CORD.

 The power service outlet 

must be within reach of the pump’s power cord plug. A fire hazard 
or electric shock could occur if the insulation on an extension cord 
becomes damaged. Fatal electrical shock could occur if the extension 
cord falls into the water.

s

!

WARNING

 The pump motor is equipped 

with an automatic resetting thermal protector and may restart 
unexpectedly. Protector tripping is an indication of motor 
overloading/overheating, which can be caused by application issues 
such as an obstructed pump impeller, pump running dry, pump air-
locked, pump short cycling, excessively high or low voltage supply, or 
possibly a pump, motor, bearings or seal that have reached the end of 
their useful life.

s

!

WARNING

 The pump is immersed in 

water during normal operation. Water may also be present in the 
surrounding area of the pump. Caution must be used to prevent 
bodily injury when working near the pump:

a. Electrical power should be disconnected prior to touching, 

servicing or repairing the pump.

b. To minimize possible fatal electrical shock hazard, extreme 

care should be used when changing fuses. Do not stand  
in water while changing fuses or insert your finger into  
the fuse socket.

s

!

WARNING

 Do not run the pump dry. The 

surface temperature of the pump will rise to a high level. This high 
level could cause skin burns if the pump is touched and will cause 
serious damage to your pump. For optimal cooling and to prolong the 
motor life, the liquid level being pumped should normally be above 
the top of the pump housing.

s

!

WARNING

 Do not oil the motor. The pump 

housing is sealed. Use of oil could cause serious electric shock and/or 
permanent damage to the pump.

s

!

CAUTION

 

THIS PUMP HAS BEEN EVALUATED FOR USE WITH WATER ONLY.

W A R N I N G

W A R N I N G

Содержание LG-MPA33

Страница 1: ...Contents Before Getting Started 2 Introduction 3 Safety Guidelines 3 Installation 4 Typical Installations 4 Wiring 5 Specifications 5 Maintenance 5 Additional Parts 6 Troubleshooting 6 Limited Warranty 8 1 3HPMULTI PURPOSEPUMP LG MPA33 ...

Страница 2: ... USED WITH LIQUIDS COMPATIBLE WITH PUMP COMPONENT MATERIALS s WARNINGMake certain that the unit is disconnected from the power source before attempting to service or remove any component If the power disconnect is out of sight lock it in the open position and tag it to prevent unexpected application of power s WARNINGThis equipment should be installed and serviced by technically qualified personne...

Страница 3: ...sure each electrical outlet should be checked with an Underwriters Laboratory Listed circuit analyzer This will indicate if the power neutral and ground wires are properly connected If they are not call a qualified licensed electrician s WARNINGRISK OF ELECTRIC SHOCK AND FIRE HAZARD DO NOT USE AN EXTENSION CORD The power service outlet must be within reach of the pump s power cord plug A fire haza...

Страница 4: ...nic corrosion may occur The recommended solution to this situation is the use of a sacrificial anode attached to the pump The anode works on the same principle as the anode found in hot water heaters and boat motors Contact your local supplier or call 1 888 956 0000 for information on where to purchase a Little Giant SA 1 Sacrificial Anode 599002 4 Position the free end of the hose or pipe where t...

Страница 5: ...ds providing sufficient motor cooling and bearing lubrication However for the best cooling and longest motor life the liquid level being pumped should normally be above the top of the motor housing MAINTENANCE s CAUTIONBefore working on the pump always unplug the pump power cord in addition to removing the fuse or shutting off the circuit breaker This unit is permanently lubricated Oiling is not r...

Страница 6: ...ean impeller See Maintenance section Lift too high for pump Check rated pump performance Inlet to impeller plugged Pull pump and clean Pump does not deliver rated capacity Lift too high for pump Check rated pump performance Partially blocked inlet Clean inlet Impeller or discharge pipe is clogged Pull pump and clean Check hose for kinks or blockage Impeller wear due to abrasives Replace pump ADDIT...

Страница 7: ...7 NOTES ...

Страница 8: ... has been used for purposes other than those for which it was designed and manufactured 8 Any use of the product where installation instructions and or instructions for use were not followed 9 Products connected to voltage other than indicated on nameplate 10 Products where the pump was exposed to any of the following sand gravel cement grease plaster mud tar hydrocarbons hydrocarbon derivatives o...

Страница 9: ...esmatières Avant de commencer 2 Introduction 3 Directives de sécurité 3 Installation 4 Installation typique 4 Câblage 5 Spécifications 5 Entretien 5 Pièces supplémentaires 6 Dépannage 6 Garantie limitée 7 POMPEÀUSAGES MULTIPLESDE1 3CV LG MPA33 ...

Страница 10: ...S MATÉRIAUX DES COMPOSANTS DE LA POMPE s AVERTISSEMENT Assurez vous que la pompe est débranchée de la source d alimentation avant de réparer l appareil ou d en retirer un composant Si le raccordement à la source d alimentation n est pas visible verrouillez le en position ouvert et étiquetez le pour éviter la mise sous tension par inadvertance s AVERTISSEMENT Cet équipement doit être installé et en...

Страница 11: ...nalyseur de circuit répertorié par Underwriters Laboratory Un tel appareil indiquera si les fils d alimentation de connexion neutre et de mise à la terre sont correctement branchés Si ce n est pas le cas appelez un électricien qualifié et autorisé s AVERTISSEMENT RISQUE DE DÉCHARGE ÉLECTRIQUE ET D INCENDIE NE PAS UTILISER UNE RALLONGE ÉLECTRIQUE La prise de courant doit être à la portée de la fich...

Страница 12: ... dans l étang ou la fontaine il peut y avoir corrosion galvanique Pour y remédier attacher une anode réactive à la pompe Cette anode fonctionne comme celles qu on trouve sur les chauffe eaux instantanés et les moteurs de bateaux Contactez votre fournisseur local ou composez le 1 888 956 0000 pour obtenir de l information sur l achat d une anode sacrificielle SA 1 de Little Giant no 599002 4 Placez...

Страница 13: ... AVANT D EN FAIRE L ENTRETIEN 3 Inspectez les cordons d alimentation et la prise électrique pour la présence de dommages ou de corrosion a Le cordon d alimentation de ces unités ne peut pas être remplacé En cas de dommages l unité au complet doit être remplacée 4 Le nettoyage périodique de la pompe augmentera sa durée de vie et son efficacité Enlever les quatre vis retentant la base sur le boîtier...

Страница 14: ...levée pour la pompe Vérifiez le rendement nominal de la pompe L aspiration vers l impulseur est obstruée Retirez la pompe et nettoyez la La pompe ne fonctionne pas à sa capacité nominale L élévation est trop élevée pour la pompe Vérifiez le rendement nominal de la pompe Admission partiellement obstruée Nettoyez l admission Le tuyau de refoulement ou l impulseur est obstrué Retirez la pompe et nett...

Страница 15: ... 10 Produits où la pompe a été exposée à l un des éléments suivants sable gravier ciment graisse plâtre boue goudron hydrocarbures dérivés d hydrocarbure huile essence solvants etc ou autres substances abrasives ou corrosives 11 Les produits dans lesquels la pompe a été utilisée pour pomper ou faire circuler des liquides autres que de l eau douce à température ambiante 12 Produits dont la pompe a ...

Страница 16: ...Form 998095 Rév 000 10 17 Pour l aide technique des parties ou la réparation entrez s il vous plaît en contact 888 956 0000 ...

Страница 17: ... Introducción 3 Pautas de seguridad 3 Instalación 4 Instalación típica 4 Cableado 5 Especificaciones 5 Maintenmiento 5 Piezas adicionales 6 Solución de problemas 6 Garantía limitada 7 Manual del propietario BOMBAMULTIUSOSDE1 3HP LG MPA33 ...

Страница 18: ...A SOLO DEBE USARSE CON LÍQUIDOS COMPATIBLES CON SUS MATERIALES COMPONENTES s ADVERTENCIA Asegúrese de que la unidad esté desconectada de la fuente de alimentación antes de intentar realizar mantenimiento o quitar cualquier componente Si el interruptor de alimentación no está a la vista bloquéelo en posición abierta y etiquételo para evitar una aplicación imprevista de alimentación eléctrica s ADVE...

Страница 19: ...medida de seguridad se debe verificar cada salida eléctrica con un analizador de circuito indicado de Underwriters Laboratories Esto indicará si los cables de conexión a tierra neutrales y de alimentación eléctrica están conectados correctamente Si no lo están comuníquese con un electricista calificado con licencia s ADVERTENCIA RIESGO DE DESCARGA ELÉCTRICA E INCENDIO NO UTILICE UN CABLE DE EXTENS...

Страница 20: ...a solución recomendada para esta situación es el uso de un ánodo de sacrificio conectado a la bomba Este ánodo trabaja bajo el mismo principio de los ánodos que se encuentran en los calentadores de agua y motores para embarcaciones Póngase en contacto con su proveedor local o llame al 1 888 956 0000 para obtener información sobre dónde comprar un ánodo galvánico Little Giant SA 1 n º 599002 4 Colo...

Страница 21: ...lado del estátor del motor o alteración eléctrica anula todas las garantías 2 DEJE QUE LA BOMBA SE ENFRÍE DURANTE UN MÍNIMO DE DOS HORAS ANTES DE INTENTAR INSPECCIONARLA 3 Verifique que no haya daños o corrosión en los cables de alimentación y en la salida eléctrica a El cable de alimentación en estas unidades no se puede reemplazar En caso de daño se debe reemplazar la unidad completa 4 Al limpia...

Страница 22: ...la bomba y averigüe la causa p ej turbina atascada Interruptor defectuoso Reemplace el interruptor Motor defectuoso Reemplace la bomba La bomba anda pero no descarga líquido Turbina atascada Quite la turbina y limpie Consulte la sección Mantenimiento La elevación es demasiado alta para la bomba Verifique el rendimiento nominal de la bomba La entrada al impulsor está tapada Saque la bomba y límpiel...

Страница 23: ...os cuales la bomba fue utilizada para bombear o circular otra cosa aparte de agua potable a temperatura ambiente 10 Productos en que la bomba haya sido expuesta a cualquiera de los siguientes elementos arena grava cemento grasa yeso lodo alquitrán hidrocarburos derivados de hidrocarburos aceite gasolina solventes etc u otras sustancias abrasivas o corrosivas 11 Productos en los cuales la bomba fue...

Страница 24: ...Para la ayuda ténica partes o la reparación por favor póngase en contacto 888 956 0000 Form 998095 Rev 000 10 17 ...