PUMP PERFORMANCE AND SIZING CHART

MODEL 

NO.

CATALOG 

NO.

HP

PH

VOLTS

HZ

AMPS

GPM @ HEAD

SHUT OFF 

(FT)

POWER 

CORD (FT)

10'

20'

40'

60'

80'

100'

120'

GP-M231/

GP-M201

520865/

520855

2

1

230/

208

60

13.9

33

32

31

30

25

20

10

130

15'

INTRODUCTION

EN

This instruction sheet provides you with the information required to safely own 
and operate your product. Retain these instructions for future reference.
The product you have purchased is of the highest quality workmanship and 
material, and has been engineered to give you long and reliable service. This 
product has been carefully tested, inspected, and packaged to ensure safe 
delivery and operation. Please examine your item(s) carefully to ensure that no 
damage occurred during shipment. If damage has occurred, please contact the 
place of purchase. They will assist you in replacement or repair, if required.

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING 
TO INSTALL, OPERATE, OR SERVICE YOUR PRODUCT. KNOW THE 
PRODUCT’S APPLICATION, LIMITATIONS, AND POTENTIAL HAZARDS. 
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY 
INFORMATION. FAILURE TO COMPLY WITH THESE INSTRUCTIONS 
COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!

DESCRIPTION

Little Giant Submersible GP-M231/GP-M201 Series Grinder Pumps are recom-
mended for use in basins or lift stations and suitable for pumping residential 
sewage, effluent, wastewater and other non-explosive, non-corrosive liquids.
Little Giant Grinder pumps utilize a cutting mechanism located on the suction 
side of the pump. The solids are cut into a slurry which pass directly through 
the volute into the discharge line by an impeller.
Little Giant offers complete control panel systems for automatic operation along 
with a complete line of alarms, basins, covers, and check valves. A Little Giant 
Pump panel or capacitor and relay kit must be used for proper operation.

SPECIFICATIONS

Discharge Size:

  GP-M231/GP-M201 - 1-1/4" FNPT Vertical

Operating
Capabilities:

 140°F 

(60°C)

Pump Housing:

  Cast iron with epoxy paint coating 

Volute:

 

Cast iron with epoxy paint coating

Impeller:

 

Brass with pressure relief vanes

Motor:

 

3450 RPM with automatic high temperature protection

Hardware:

 

300 series stainless steel 

Bearings:

 

Upper and lower ball

Shaft Seal:

 

Type 21 mechanical, spring loaded, rotating carbon with 
Viton

®

 bellows and ceramic stationary with Viton

®

 O-ring

Power Cord:

 

14 AWG 4-conductor, copper, stranded

Cooling:

 

The motor housing contains a dielectric oil to provide cool-
ing for the motor and to lubricate the bearings and seals. 
These pumps are capable of operating with the motor hous-
ing partially exposed for extended periods of time, providing 
sufficient motor cooling and bearing lubrication. However, 
for the best cooling and the longest motor life, the liquid 
level being pumped should normally be above the top of the 
cast iron motor cover.

Cutters:

 

440C stainless steel, hardened to Rockwell C 55-60

SAFETY GUIDELINES

Read all instructions and Safety Guidelines thoroughly. Failure to follow the 
guidelines and instruction could result in serious bodily injury and/or property 
damage.

WARNING: Risk of electric shock.

 This pump is supplied with a grounding 

conductor. To reduce the risk of electric shock, be certain that it is connected 
only to a properly grounded, grounding-type receptacle in the control panel.
When a pump is in a basin, etc., do not touch motor housing, pipes or water 
until unit is unplugged or shut off. If your Installation has water or moisture pres-
ent, do not touch wet area until all power has been turned off. If shut-off box 
is not accessible, call the electric company to shut off service to the house, or 
call the local fire department for instructions. Failure to follow this warning can 
result in fatal electric shock. 
The flexible jacketed cord assembly mounted to the pump must not be modi-
fied in any way. Do not use the power cord for lifting the pump.
 1.  DO NOT USE TO PUMP FLAMMABLE OR EXPLOSIVE FLUIDS SUCH AS 

GASOLINE, FUEL OIL, KEROSENE, ETC. FAILURE TO FOLLOW THIS 
WARNING CAN RESULT IN PERSONAL INJURY AND OR PROPERTY 
DAMAGE.

 2.  The pump motor is equipped with an internal thermal protector switch that 

opens to stop the motor when exceeding normal operating temperatures. 
This switch will reset itself and start the pump when cooled to normal tem-
peratures.

 3.  During normal operation the grinder pump is immersed in water. Also, 

during rain storms, water may be present in the surrounding area of the 
pump. Caution must be used to prevent bodily injury when working near 
the pump.

  a. Electrical power must be disconnected prior to touching, servicing or 

repairing the pump.

  b.  To minimize possible fatal electrical shock hazard, extreme care should 

be used when changing fuses. Do not stand in water while changing 
fuses or insert anything other than a fuse in the fuse socket.

 4.  Do not run the pump in a dry basin. If the pump is run in a dry basin, the 

surface temperature of the pump will rise to a high level. This high level 
could cause skin burns if the pump is touched and will cause serious dam-
age to your pump.

 5.  Do not oil the motor. The pump housing is sealed. A high grade dielectric 

oil devoid of water has been put into the motor housing at the factory. Use 
of other oil could cause serious electric shock and/or permanent damage 
to the pump.

 6.  Do not install in locations classified as hazardous in accordance with the 

National Electric Code, ANSI/NFPA 70.

  7.  Do not place hands, feet or clothing near the cutter mechanism when there 

is any possibility the pump is connected to a power source. This pump 
contains a cutting mechanism with very sharp edges that can cause severe 
bodily injury.

INSTALLATION

For automatic operation, pump must be wired into a control panel. Installation 
instructions are included with all Little Giant control panels and should be 
referred to for installation. 
Pump will not run if wired directly into an electrical outlet. This pump requires 
a Little Giant capacitor kit and or control panel, which contains the appropriate 
start and run capacitors in conjunction with a relay for proper operation. Refer 
to the instruction manual for capacitor kit or control panel to obtain proper 
component values. If this pump is run with incorrect capacitors or relay, there 
could be severe damage to the pump motor and or control panel. 
Pump must be installed in a suitable basin, which is at least 24" in diameter and 
36" deep, and vented in accordance with local plumbing codes. 
It is recommended for best performance and satisfactory installation to use a 
complete factory built basin package system. This system includes optimum 
materials of construction for operation. 
Pump must be placed on a hard level surface using a leg accessory kit avail-
able from Little Giant if unable to suspend the pump intake at least 3-1/2" from 
bottom of basin. 
Never place pump directly on clay, earth or gravel surfaces.
Pump can be installed with ABS, PVC, polyethylene or galvanized steel pipe. 
Proper adapters are required to connect any non-metal pipe to the pump dis-
charge if pump is suspended by the discharge on a guide rail system. 

GP-M231

GP-M201

1 Phase

Franklin Electric Co., Inc.

P. O. Box 12010

Oklahoma City, OK 73157-2010

405.947.2511 • Fax: 405.947.8720

www.LittleGiantPump.com

[email protected]

1

Содержание GP-M201

Страница 1: ... off box is not accessible call the electric company to shut off service to the house or call the local fire department for instructions Failure to follow this warning can result in fatal electric shock The flexible jacketed cord assembly mounted to the pump must not be modi fied in any way Do not use the power cord for lifting the pump 1 DO NOT USE TO PUMP FLAMMABLE OR EXPLOSIVE FLUIDS SUCH AS GA...

Страница 2: ...moved from the volute without having to remove the volute 3 Remove the stationary cutter from the volute If the stationary cutter is worn it can be turned over once to utilize the other cutter edge If the stationary cutter is damaged it must be replaced 4 Under good light inspect the two edges of the rotation cutter If the rota tion cutter edges appear dull pitted or otherwise damaged it should be...

Страница 3: ...atique haut température sau vegarde Attaches Acier inoxydable série 300 Roulements Roulement inférieur et supérieur Joint étanche de l arbre Modèle mécanique 21 tendu par un ressort avec souff lets en Viton à carbone pivotant et céramique fixe avec rondelles en Viton Cordon d alimentation 14 AWG 4 conducteurs cuivre à torons Refroidissement Le boîtier du moteur renferme une huile de diélectrique p...

Страница 4: ...té du cordon Consulter les instructions du panneau de commande pour obtenir le schéma de câblage complet ENTRETIEN Si la pompe ne fonctionne pas bien consulter le tableau de dépannage Si le problème ne peut être identifié à l aide des étapes indiquées consulter le con cessionnaire qui vous a vendu la pompe ou apporter la pompe à un centre de service autorisé Little Giant La pompe broyeuse doit êtr...

Страница 5: ...me a la empresa de servicio eléctrico para que desac tive el servicio a su casa o llame al cuerpo de bomberos local para obtener instrucciones Si no sigue esta advertencia puede recibir un choque léctrico mortal El ensamblaje del cable flexible con revestimiento viene montado en la bomba y no se debe modificar de ninguna forma No levante la bomba por el cable de alimentación 1 Lea todo el instruct...

Страница 6: ...los desechos y sedimentos antes de desarmarla ADVERTENCIA Esta bomba cuenta con un mecanismo de corte con bordes extremadamente afilados Se debe ejercer precaución cuando trabaje sobre o cerca de estas piezas 1 Coloque la bomba de lado sobre una superficie lisa y dura Antes de sacar la espiral coloque una marca entre la placa de sello y la espiral Para obtener acceso al cortador rotativo saque la ...

Страница 7: ...tter 1 5 14940256 Screw Washer Hex Head 3 8 16 x 1 1 2 SST 3 6 903740 Screw Washer Hex Head 5 16 18 x 1 2 SST 3 520857 Kit Run Start Capacitor Relay w Hardware 1 950532 Start Capacitor 1 950533 Run Capacitor 1 950537 Start Relay 1 599078 OPTIONAL LGP SERIES LEG KIT Item No Part No Description Qty 6 903740 Screw Washer Hex Head 5 16 18 x 1 2 SST 3 7 120903 Leg Accessory 3 8 921105 Washer Lock 5 16 ...

Страница 8: ...illed in discharge pipe approximately 2 above discharge connection If there is already a hole drilled check for stuck debris Couper le courant pendant 1 minute environ puis recommencer Répéter cette opération plusieurs fois pour évacuer l air de la pompe S il y a une soupape d arrêt percer un trou de 3 16 po dans letuyau d écoulement à environ 2 po au dessus des connexions d écoulement S il y a dé...

Страница 9: ...ciones o defectos Basin too small for inflow Bassin de réception trop petit pour l afflux El fondo del sumidero es muy pequeño o está inundado Install larger basin Installer un bassin plus grand Instale una cubeta más grande Pump is noisy La pompe est bruyante La bomba hace ruido Inlet may be clogged and overloading the motor Orifice d entrée probablement obstrué et surchargeant le moteur La entra...

Страница 10: ...hatsoever in connection therewith The warranty and remedy described in this limited warranty is an EXCLUSIVE warranty and remedy and is IN LIEU OF any other warranty or remedy expressed or implied which other warranties and remedies are hereby expressly EXCLUDED including but not limited to any implied warranty of MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some states do not allow the exc...

Страница 11: ...ier cliente al extraer o asegurar cualquier producto LITTLE GIANT pieza o componente de éste 1 a defectos o funcionamiento defectuoso ocasionados por no instalar operar o mantener la unidad conforme a las instrucciones escritas provistas 2 a fallas causadas por abuso accidente o negligencia 3 a servicios normales de mantenimiento y a las piezas utilizadas para prestar dichos servicios 4 a unidades...

Страница 12: ...ssistance please contact 1 888 956 0000 Pour des parties ou la réparation entrez s il vous plaît en contact 1 888 572 9933 Pour l aide technique entrez s il vous plaît en contact 1 888 956 0000 Para partes o la reparación por favor póngase en contacto 1 888 572 9933 Para la ayuda técnica por favor póngase en contacto 1 888 956 0000 www LittleGiantPump com CustomerService WTS fele com 12 ...

Отзывы: