Little Giant 12E Series Скачать руководство пользователя страница 2

SAFETY INSTRUCTIONS

Specifications

2

High voltages capable of causing severe injury or death by electrical 

shock are present in this unit.

• To reduce risk of electrical shock, disconnect power before working on or around the system. More than one disconnect 

switch may be required to de-energize the equipment before servicing.

• This product is supplied with a grounding conductor and grounding-type attachment plug. To reduce risk of electric 

shock, be certain that it is connected only to a properly grounded grounding-type receptacle. Do not remove the third 
prong from the plug. The third prong is to ground the pump to help prevent possible electric shock hazard. Do not use an 
extension cord.

• Check electrical outlets with a circuit analyzer to ensure power, neutral, and ground wires are properly connected. If not, 

a qualified, licensed electrician should correct the problem.

• Wire pump system for correct voltage.
• Check local electrical and building codes before installation. The installation must be in accordance with their regulations 

as well as the most recent National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA).

• The flexible jacketed cord assembly mounted to the pump must not be modified in any way, with the exception of short

-

ening the cord to fit into a control panel. Any splice between the pump and the control panel must be made within a 
junction box mounted outside of the basin and comply with the National Electrical Code. Employ a licensed electrician.

• Do not use the power cord for lifting the pump.
• The pump has been evaluated for use with water only. Pump should only be used with liquids compatible with pump 

component materials. If the pump is used with liquids incompatible with the pump components, the liquid can cause 
failure to the electrical insulation system resulting in electrical shock.

Risk of bodily injury, electric shock, or equipment damage.

• This equipment must not be used by children or persons with reduced physical, sensory or mental abilities, or lacking in 

experience and expertise, unless supervised or instructed. Children may not use the equipment, nor may they play with 
the unit or in the immediate vicinity.

• Equipment can start automatically. Always unplug the pump power cord and disconnect the electrical power before ser

-

vicing the pump or switch.

• An inoperative or malfunctioning pump could lead to flooding, resulting in personal injury or property damage.
• In applications where property damage and/or personal injury might result from an inoperative or leaking pump due to 

power outages, discharge line blockage, or any other reason, an automatic back-up system and/or an alarm should be 
installed.

• Do not run the pump dry. If run dry, the surface temperature of the pump will rise to a high temperature that could cause 

skin burns if touched and will cause serious damage to your pump.

• Do not oil the motor. The pump’s motor housing is sealed, with a high-grade dielectric oil for heat transfer and lifetime 

lubrication. Use of other oils could cause serious electric shock and/or permanent damage to the pump.

• Operation of this equipment requires detailed installation and operation instructions provided in this manual. Read 

entire manual before starting installation and operation. End User should receive and retain manual for future use.

• Keep safety labels clean and in good condition.

Risk of damage to pump or other equipment.

• Do not use this pump for pumping sea water, beverages, acids, chemical solutions, or any other liquid that promotes cor

-

rosion as this can result in damage to the pump.

• Do not run pump dry. For optimal cooling and to prolong the motor life, the liquid level being pumped should normally be 

above the top of the pump housing.

• This pump is not suitable for pond applications.

Содержание 12E Series

Страница 1: ...comply with national and local electrical and plumbing codes and within Little Giant recommendations may result in electrical shock or fire hazard unsatisfactory performance or equipment failure Know...

Страница 2: ...electrical insulation system resulting in electrical shock Risk of bodily injury electric shock or equipment damage This equipment must not be used by children or persons with reduced physical sensor...

Страница 3: ...TION Typical Installation 1 Gate Valve 2 Check Valve 3 Union 4 Switch power 5 Pump Power 6 Vent 7 Discharge 8 Gas tight basin 9 Intake 10 Caulking hub 11 3 16 air bleed hole 12 Tethered Float Refer to...

Страница 4: ...ge size to reduce pipe friction losses A smaller pipe will restrict capacity and reduce pump performance The pump comes with a 2 NPT female pipe thread discharge Install a union in the discharge line...

Страница 5: ...be cooled by pumping fluid The seal may be damaged and the motor may fail if the pump is allowed to run dry Pump should be totally sub merged for proper cooling of the motor when pump is operated for...

Страница 6: ...est reservoir 3 Direct the opposite end of the discharge hose back into the basin or test reservoir so that the water discharged from the hose during testing will be contained within the basin or test...

Страница 7: ...nents basin pump switch etc for any build up sludge sediment minerals etc that would inhibit functionality of the components If significant remove build up or replace affected components 4 Confirm tha...

Страница 8: ...lean air bleed hole Liquid inflow matches pump capacity Larger pump required Defective switch Replace switch Pump runs but does not discharge liquid Check valve installed back wards Check flow indicat...

Страница 9: ...eses desde la fecha original de compra por parte del consumidor Para obtener infor maci n completa sobre la garant a consulte www LittleGiant com Especificaciones INSTRUCCIONES SOBRE SEGURIDAD La inst...

Страница 10: ...de acortar el cable para que encaje en un panel de control Cualquier empalme entre la bomba y el panel de control debe hacerse dentro de una caja de conexiones montada fuera del dep sito y cumplir co...

Страница 11: ...otador adjunto Consulte Especificaciones en la p gina 9 para el nivel ON y el nivel OFF Riesgo de da os a bomba u otros equipos No use esta bomba para bombear agua de mar bebidas cidos soluciones qu m...

Страница 12: ...er a de descarga debe tener el mismo di metro que el tama o de descarga para reducir las p rdidas por fricci n de la tuber a Una tuber a m s peque a restringir la capacidad y reducir el rendimiento de...

Страница 13: ...su propio circuito sin otras salidas o equipos en la l nea de cir cuito No lo conecte a un ventilador ni a un dispositivo que funcione de manera intermitente Los fusibles y el disyuntor deben tener un...

Страница 14: ...o de energ a adecuado que tenga un voltaje congruente con el voltaje de la bomba como se indica en la placa de identificaci n de la bomba 2 Si la l nea de descarga tiene una v lvula de compuerta verif...

Страница 15: ...un enchufe de seguridad en el cable de alimentaci n enchufe el cable de ali mentaci n de la bomba a un recept culo con un interruptor de circuito por falla de conexi n a tierra GFCI por si sigla en in...

Страница 16: ...y retire dep sitos o residuos Limpiar el impulsor y la voluta 1 Retire los cuatro pernos y cuatro arandelasque fijan la voluta a la carcasa del motor 1 Luego separe la voluta del carcasa del motor IM...

Страница 17: ...mprobar que funcione bien Elevaci n demasiado alta para la bomba Revise el desempe o nominal de la bomba Entrada al impulsor obstruido Quite la bomba y l mpiela La bomba est obturada por aire Si est o...

Страница 18: ...Inc Oklahoma City OK 73157 2010 800 701 7894 littlegiant com Para la ayuda t cnica por favor p ngase en contacto Form 10000004899 Rev 001 12 20 Copyright 2020 Franklin Electric Co Inc Todos los derec...

Страница 19: ...ments ou un joint ayant atteint la fin de sa leur vie utile Ce produit est couvert par une garantie limit e pour une p riode de 36 mois compter de la date d achat originale par le consommateur Pour ob...

Страница 20: ...ce soit Il peut uniquement tre rac courci si cela est n cessaire pour le faire rentrer dans le panneau de commande Toute pissure entre la pompe et le panneau de commande doit tre r alis e dans une bo...

Страница 21: ...Sp cifications page 19 pour les niveaux sur et arr te Risque de dommages la pompe ou d autres quipements Ne pas utiliser la pompe pour pomper de l eau de mer des boissons de l acide des solutions chi...

Страница 22: ...t comporter le moins de coudes pos sible Le tuyau de refoulement doit avoir un diam tre sup rieur ou gal la taille de refoulement de la pompe Un tuyau de diam tre inf rieur limitera les capacit s et r...

Страница 23: ...ompe doit tre connect e ou branch e sur son propre circuit sans autre prise ou quipement sur la ligne du circuit Ne le raccordez pas un ventilateur ou tout dispositif fonctionnant par inter mittence L...

Страница 24: ...rente avec la tension de la pompe indiqu e sur la plaque signal tique de celle ci 2 Assurez vous que le robinet vanne du conduit de refoulement est ouvert 3 Faites couler de l eau dans le bassin jusqu...

Страница 25: ...ai 6 Branchez le cordon d alimentation de la pompe dans un r ceptacle de disjoncteur de fuite de terre GFCI avec une tension compatible avec la tension de la pompe comme indiqu sur la plaque signal ti...

Страница 26: ...e l impulseur et de la volute 1 Retirez les quatre boulons et les quatre rondelles qui fixent la volute au bo tier du moteur 1 Puis s parez la volute du bo tier du moteur IMPORTANT Ne pas retirer le c...

Страница 27: ...vation est trop lev e pour la pompe V rifiez le tableau des valeurs nominales L aspiration vers l impulseur est obstru e Retirez la pompe et nettoyez la La pompe est bloqu e par de l air Enlever la po...

Страница 28: ...Co Inc Oklahoma City OK 73157 2010 800 701 7894 littlegiant com Pour l aide technique entrez s il vous pla t en contact Droits d auteur 2020 Franklin Electric Co Inc Tous droits r serv s Form 10000004...

Отзывы: