Generator Control Module
The Generator Control Module is designed to work with generators that accept a closed circuit-
start/open circuit-stop signal. This module will automatically start and stop the generator. In
addition to this, the BMS reset momentary button can be short pressed by the user to reverse the
generators state at any time. This allows convenience/opportunity charging along with automatic
charging start/stop functionality.
The start and stop points of the generator can be user programmed as follows:
Low Fuel – When the SoC Meter is at the low fuel level (see page 8 - Low Fuel) it will trigger the
generator to start automatically.
Full Voltage – When SOC full voltage is reached (see page 8 - Full Vlt) the SOC meter calibrates to
100% and the generator is commanded to turn off.
There is 1 pair of wires that need to be connected for the Generator Control Module to interface
correctly with the generator. They are:
Start – 2 wire isolated 2 amp 250V max N/O circuit (closes to start generator, opens to stop)
Generator Wiring Example: