Using The SoC Meter’s Interface via SoC Display Unit:

 

 

T h e   SoC meter  has  a  dual line  LCD  screen capable  of  showing  2  pieces  of data independently. 
Pressing the upper  button  scrolls  through  available  data  on  upper  line,  pressing  lower  button 
scr o lls  t h r o u gh   available  data  on  the  lower  line.  Any  combination of  data  is  possible on 
t h e s e   2  lines.  The following list explains all available data counters: 

 

E

 

 

 

 

 

 

 

F

 

–  Graphical representation of  the  Fuel  Gauge.  Each  of the  6  bars  corresponds to 

approximately  17% of capacity.

 

 

100% Fuel 

– Percentage of digital Fuel gauge. Fuel is derived from SoC minus the Low Fuel setting 

explained in the Calibration/Settings section below.

 

 

100% SoC 

– State of Charge. The percent of usable energy left in the battery.

 

 

23.4 A 

– Amperage. Instant current reading. A  “+” sign in front of the value indicates charging 

current.  No sign indicates discharging current.

 

 

20000 W 

– Instant Wattage reading. This power value is derived by multiplying current and 

voltage.  This  is  useful to  estimate how much instant power is  passing through the battery 
circuit. This value can be manually converted to horse power by the formula: Watts/745.7=HP 

 

39.6 V Pk 

– Pack voltage reading.

 

 

82F Tmp 

– Instant temperature  reading at the sender  board location. Can be set to C or F. See 

“Zero-Point Calibrations and Settings” section.

 

 

100.0 Ah 

– Remaining Amp Hour  capacity  of the battery. 

 

3960  Wh 

–  Remaining  Watt  Hour  capacity  of  the  battery.  Watt  Hour  value  is  derived  by 

multiplying  t h e   Amp Hour  value  and  the  Pack  Voltage together. This  value  will  be  changing 
dynamically  as voltage fluctuates with load.

 

 

 

 
 
 
 
 
 
 
 
 

Содержание State of Charge V6 Meter

Страница 1: ...f the configuration variables are set correctly which are pre set initially by Lithionics Battery but user adjustable with supporting hardware If they are ever accidently modified a record of the defa...

Страница 2: ...n SoC sending box for collecting and computing data points List of accessories for the SoC Sending Box Round SoC Display Gauge Pod Bi Directional Serial ASCII Data Formats o USB o RS232 via DB9 o TTL...

Страница 3: ...Page 10 o 3 Bit Register Page 11 o Generator Control Module Page 12 Serial Data Outputs o USB DB9 RS232 Page 13 o Bluetooth Serial Data Page 13 o Ethernet TCP IP Interface Page 13 TCP IP Configuratio...

Страница 4: ...external NeverDie unit turn it off as well 2 Connect the SoC NEGATIVE REFERENCE WIRE to the battery negative terminal 3 Connect the battery positive to the BATTERY on the SoC Sender Box NOTE If you ha...

Страница 5: ...nect the screw connector to the panel interface with the two highlighted indentations mating with each other 3 While pressing the ring down lightly rotate the ring counter clockwise until you feel a l...

Страница 6: ...w 100 SoC State of Charge The percent of usable energy left in the battery 23 4 A Amperage Instant current reading A sign in front of the value indicates charging current No sign indicates discharging...

Страница 7: ...in 20 seconds then Setup Mode will time out and switch to display mode automatically Below is the listing of all setup screens and their variable descriptions The factory default values are recorded f...

Страница 8: ...SOC reading still remains true to battery capacity regardless of the temperature Low Fuel Low Fuel level This percentage value determines the minimal Fuel Gauge level at which the Low Fuel circuit is...

Страница 9: ...with a digital multi meter in DC amperage mode in series with the SoC NEGATIVE REFERENCE WIRE Allowed range is 0mA 200mA Cell Count This setting must be set to the number of cells in series Example 1...

Страница 10: ...s 0V when inactive and 5V when active It corresponds to the Low Fuel setting in the user menu 2 Full Charge The Full Charge output circuit is 0V when inactive and 5V when active It corresponds exclusi...

Страница 11: ...uts 1 3 represent a 3 bit register with binary output for SOC Outputs 1 3 goes 0 5V binary 0 or 1 Out3 is least significant bit LSB Out 1 is most significant bit MSB SOC 100 all 3 bits are high SOC 0...

Страница 12: ...with automatic charging start stop functionality The start and stop points of the generator can be user programmed as follows Low Fuel When the SoC Meter is at the low fuel level see page 8 Low Fuel...

Страница 13: ...Settings Speed Baud 9600 Data bits 8 Stop bits 1 Parity None Bluetooth Serial Data The Bluetooth module will output the same fixed length data stream as the serial data output above at the same 1 seco...

Страница 14: ...r configuration purposes as it allows to send complete string rather than one character at a time as most programs do Once SOC Gauge is configured with desired IP addressing it can be connected to liv...

Страница 15: ...ry LLC SOCV6 REV0 PRE RELEASE 15 Battery Module Ethernet TCP IP Physical Interface Typically the physical interface is a M12 D Coded connector which is an industrial weather resistant standard for RJ4...

Страница 16: ...000000T000R00000 Data packet fields B Battery address typically 1 in multi battery systems this will represent battery order 1 digit long H AmpHours remaining in 0 1Ah resolution i e 123 12 3Ah 5 digi...

Страница 17: ...rough Putty Using USB Serial DB9 Interface CSV Line Definitions RAW Code B H328 V269 F92 S93 D0 A0 W0 T91 E Begin Amp Hours Voltage Fuel State Of Charge Current Direction Charge1 Discharge0 Amps Watts...

Страница 18: ...mode and Data Mode Commands listed below List of all AT commands Commands listed below must be followed by new value after sign If new value is outside of expected range error message will be sent If...

Страница 19: ...END End Setup mode and resume to normal Data mode AT SETUP Halt normal operation and enter Setup mode Data Mode commands During data mode SOC Gauge can receive and process real time commands listed b...

Страница 20: ...E State of the battery represents one of basic conditions of a battery in real time Status Byte is the last byte of parameter R in Serial Ethernet streams In CANBus stream it is the first byte in the...

Страница 21: ...Full voltage Empty voltage Resolution 0 1V range 0V 6553 5V CUR Instant current Resolution 0 1A range 0A 6553 5A DIR Current direction 1 charging 0 discharging PWR Watts instant Resolution 1W range 0...

Страница 22: ...2016 Lithionics Battery LLC SOCV6 REV0 PRE RELEASE 22 Default values for battery system ____ ____ VAh 64V Ah V 20 Normal 10 10 F 96 0 3 Off 0 1000A 0 0 mA No...

Отзывы: