background image

Page 7 of 8 

Pr01 
Pr02 
Pr03 
Pr04 
Pr05 
Pr06 
Pr07 
Pr08 

 

 
 

Program 1: auto  

Program 2 : auto   

Program 3: auto  

Program 4 : auto 

Program 5: auto  

Program 6 : auto 

Program 7: auto  

Program 8 : auto   

   
   

 

Automatic mode without DMX 512 Protocol 

signal.Program selections run between Pr01 

through Pr 08. Both programs can be modified. 

To change program select Enter then view 

(Scn0…Scn9; max scenes of each program). 

Clicking on enter once more it shows  P.00.0 

(time) followed by F.00.0 (speed) and ultimately  

the last view shows 1c.01… though c12 (colour 

to be assigned to each scene) The use of 

UP/Down keys allow for setting values. When 

selections are completed press enter to confirm  

MaSL

 

 

                                              Master Mode  

The Master Mode uses the same settings as the Auto Menu. The only 

exception is that when all fixtures are connected to DMX 001 in daisy-chain, 

they perform the same presets and or the same presets selected on the 

Master fixture 

Mode 

     8 ch (D) 

RGBAW 8 ch (default) 

Dmx  mode (view next page) 

2 ch 

2 ch 

14 ch 

RGBAW 14 ch (16 bit) 

5 ch 

RGBAW 5 ch 

drUt

 

..°C 

Shows driver operating temperature

 

LEdt

 

..°C 

Shows leds operating temperature

 

PUM

 

0..100% 

Shows current led power (0-100%) 

SMOO

 

FAST 

MED 

SLOW 

DMX data Speed adjustment       

         GAMM

 

LInE 

qUAd 

Dimmer profile selection: 

- LinE for linear dimming regulation 

- qUAd for tungsten lamp emulation 

FREQ 

1K 
2K 
3K 
4K 
5K 
6K 
7K 
8K 
9K 

10K 

LED operation frequence 

      booS

 

Off 

on 

When OFF,  LED max flux : 80% 

When ON, LED max flux : 100% 

FAn 

Aut 

MEDH 

MEDL 

 LOW 

4 fan operating modes i.e atuomatic, medium fast, medium slow, slow 

speed.  

Fan speed adjujstments (fan-sound) reflect on self-correct  output LED 

brightness and other factors as room-temperature, number of  engaged 

channels

   

PoS

 

AA 
VV 

Display orientation selection: 

AA = normal 

VV = inverted 

StbY

 

Off 

on 

Standby display activity: 

   off = display always switched on = display  switched off after few seconds of 

buttons inactivity (only the right side dot will be lighted to indicate DMX 

availability) 

dEF

 

Off 

on 

ON Will restore the default factory values

 

TiML 

..h ..  

Shows LED life

 

TiMU 

..h ..  

Shows HPLed life

 

SoFt 

 

Shows Software version

 

 

DMX Operating Modes (Mode) 

Selecting 1 of the 4 available modes it enables the number of  channels required, and its relevant modes, 
needed  to operate Lites Profile C5 T  

mode  8 ch RGBAWi (default) 

 

Ch 

Function  

dmx levels  

red 

0..255 

From 0 to max  255 

green 

0..255 

From 0 to max  255 

blue 

0..255 

From 0 to max  255 

white 

0..255 

From 0 to max  255 

amber 

0..255 

From 0 to max  255 

 

 

strobe 

 0…15 

Strobo disingaged  

16…255 

Strobo from slow  (16) to fast (255) 

 

 

Rainbow 

0..15 

Rainbow disingaged  

16..255 

Rainbow from slow  (16) to fast (255)  

dimmer 

0..255 

From 0 to max  255 

 

Содержание PROFILE C5

Страница 1: ...ssential to read and follow guidelines and other information contained in this manual to ensure correct installation service and full operations of the HPLED All operations must be accomplished handled and carried out by qualified personnel only NOT COMPLYNIG WITH GIVEN NOTICE WILL VOID WARRANTY AND WILL TOTALLY DISCHARGE THE MANUFACTURER FROM ANY RESPONSABILITY www litessrl com ...

Страница 2: ...Profile C5 is rated Class I Protection rating IP20 Earth connection is MANDATORY LED core must never be touched in any way as it may impair its use An essential and periodically throughout cleaning of the Lites Profile C5 is recommended This practice avoids that layers of dust and other impurity put at risk and reduce the correct operation of the unit Lenses must be cleaned remove layers of dust t...

Страница 3: ...pecifications Weight 7 5 Kg IP Rating 20 Working position Any Power connectors IN OUT Neutrik PowerCon Data connectors IN OUT XRL5 Data protocols DMX 512 RDM ready User interface 4 digit display and 4 buttons Manual operation Users must operate via buttons provided on the display Fan control Fan speed adjustment Control of LED frequency Selection of LED frequency refresh 2 Dimming curves control S...

Страница 4: ...e accomplished handled and carried out by qualified personnel only and must comply meet with all norms in force in the installation s country Lites Profile C5 is supplied with a free Blue Neutrik PowerCon plug that must be wired using a 3x1 5mm lead Additional specifications include Operating Voltage 300 500V Test Voltage 2KV Operating Temperature 10 C 35 C 14 F 90 F Connect blue wire to N termina...

Страница 5: ...f the Lites Profile C5 by giving a flash of light Controller sets the device to a listing to read settings DMX address personality settings i e DMX mode including all the above mentioned DMX values ON OFF Identify This mode is to identify the manufacturer s device Lites srl Flash of light is to confirm selection Model information HPLED BUCK Software version information HPLED BUCK v x xx Mode to re...

Страница 6: ... avoid injuries to third parties in the event it comes out of its place Power Lites Profile C5 ON WARNING Before powering Lites Profile C5 ensure that all installation s procedure s have s been properly set learnt and accomplished When Lites Profile C5 is powered the setup display will show the software release version The UP DOWN ENTER and ESC buttons allow the operations of Lites Profile C5 menu...

Страница 7: ...profile selection LinE for linear dimming regulation qUAd for tungsten lamp emulation FREQ 1K 2K 3K 4K 5K 6K 7K 8K 9K 10K LED operation frequence booS Off on When OFF LED max flux 80 When ON LED max flux 100 FAn Aut MEDH MEDL LOW 4 fan operating modes i e atuomatic medium fast medium slow slow speed Fan speed adjujstments fan sound reflect on self correct output LED brightness and other factors as...

Страница 8: ...matically switch off for protection Refrain from and halt the use of the Lites Profile C5 and promptly contact any authorized service centre Periodical maintenance To ensure the correct Lites Profile C5 operation we suggest the following periodical maintenance operations Remove dust or any kind of other dirt from the fans and from loop holes this operation ensures the correct air flow though vents...