Lites Profile C5 is delivered with a robust yoke that hosts 3 x 12 mm mounting holes.  
The use of an adequate G-clamp to sustain at least twice the weight of the Lites Profile C5 (Lites Profile C5 
weighs 7,5 kg) and/or M10 screw is mandatory.  The use of safety chain(s) to sustain twice the weight of the 
Lites  Profile  C5  is  also  mandatory;  the  safety  chain  adds  more  protections  and  safety  to  users  and  third 
parties. Eye-lid for the safety chain is provided on the Lites Profile C5. The unit can be installed in any position 
(See Fig)  

      

          Connection to mains

 

 

WARNING! Installation(s) must be accomplished, handled and carried out by qualified personnel 
only and must comply & meet with all norms in force in the installation's country

 

 

Lites Profile C5 is supplied with a free Blue Neutrik PowerCon plug that must be wired using a 3x1.5mm² lead 
Additional specifications include: 

 

Operating Voltage: 300/500V 

 

Test Voltage: 2KV 

 

Operating Temperature: -10°C / +35°C (- 14° F / +90° F) 

Connect blue wire to N terminal, brown wire to L terminal and Yellow/Green wire to earth terminal. Ensure to 
connect to safety  circuit breakers at all times. When  connected to  230VAC, daisy chain must not exceed the 
quantity of 10 units and 5 units when connected to 110VAC. Maximum daisy chain cable length: 20m. 

 

 

  WARNING:  NEVER  CONNECT  LITES  PROFILE  C5  ENGINE  TO  ANGLE  PHASE  DIMMER  PACK 

NOR TO NON- DIM MODE 

 

POWER

 IN

POWER 

OUT

 

Содержание PROFILE C5

Страница 1: ...ssential to read and follow guidelines and other information contained in this manual to ensure correct installation service and full operations of the HPLED All operations must be accomplished handled and carried out by qualified personnel only NOT COMPLYNIG WITH GIVEN NOTICE WILL VOID WARRANTY AND WILL TOTALLY DISCHARGE THE MANUFACTURER FROM ANY RESPONSABILITY www litessrl com ...

Страница 2: ...Profile C5 is rated Class I Protection rating IP20 Earth connection is MANDATORY LED core must never be touched in any way as it may impair its use An essential and periodically throughout cleaning of the Lites Profile C5 is recommended This practice avoids that layers of dust and other impurity put at risk and reduce the correct operation of the unit Lenses must be cleaned remove layers of dust t...

Страница 3: ...pecifications Weight 7 5 Kg IP Rating 20 Working position Any Power connectors IN OUT Neutrik PowerCon Data connectors IN OUT XRL5 Data protocols DMX 512 RDM ready User interface 4 digit display and 4 buttons Manual operation Users must operate via buttons provided on the display Fan control Fan speed adjustment Control of LED frequency Selection of LED frequency refresh 2 Dimming curves control S...

Страница 4: ...e accomplished handled and carried out by qualified personnel only and must comply meet with all norms in force in the installation s country Lites Profile C5 is supplied with a free Blue Neutrik PowerCon plug that must be wired using a 3x1 5mm lead Additional specifications include Operating Voltage 300 500V Test Voltage 2KV Operating Temperature 10 C 35 C 14 F 90 F Connect blue wire to N termina...

Страница 5: ...f the Lites Profile C5 by giving a flash of light Controller sets the device to a listing to read settings DMX address personality settings i e DMX mode including all the above mentioned DMX values ON OFF Identify This mode is to identify the manufacturer s device Lites srl Flash of light is to confirm selection Model information HPLED BUCK Software version information HPLED BUCK v x xx Mode to re...

Страница 6: ... avoid injuries to third parties in the event it comes out of its place Power Lites Profile C5 ON WARNING Before powering Lites Profile C5 ensure that all installation s procedure s have s been properly set learnt and accomplished When Lites Profile C5 is powered the setup display will show the software release version The UP DOWN ENTER and ESC buttons allow the operations of Lites Profile C5 menu...

Страница 7: ...profile selection LinE for linear dimming regulation qUAd for tungsten lamp emulation FREQ 1K 2K 3K 4K 5K 6K 7K 8K 9K 10K LED operation frequence booS Off on When OFF LED max flux 80 When ON LED max flux 100 FAn Aut MEDH MEDL LOW 4 fan operating modes i e atuomatic medium fast medium slow slow speed Fan speed adjujstments fan sound reflect on self correct output LED brightness and other factors as...

Страница 8: ...matically switch off for protection Refrain from and halt the use of the Lites Profile C5 and promptly contact any authorized service centre Periodical maintenance To ensure the correct Lites Profile C5 operation we suggest the following periodical maintenance operations Remove dust or any kind of other dirt from the fans and from loop holes this operation ensures the correct air flow though vents...

Отзывы: