11/30
1.4.2.
Commissioning
1.4.2.1
The dry extraction can/may only be operated with a LISSMAC joint cutter UNICUT 500 or UNICUT
800, as the dry extraction is driven by hydraulics of the joint cutter.
1.4.3.2
Visual check of the dry extraction for damages and defects. Special control of the protection device
and the suction hoses.
1.4.3.3
The suction hose must be kept away from the exhaust of the joint cutter.
1.4.3.4
For the operation of the dry extraction, a special sawing hood for the dry extraction with
temperature-resistant exhaust hoses must be used.
1.4.3.
Operation
1.4.4.1
Refrain from working in any manner that may compromise safety.
1.4.4.2
Take measures so that the dry extraction is only operated in a safe and functional state!
1.4.4.3
Check the dry extraction at least once per shift for outwardly recognisable damages and defects!
Notify the responsible place/person immediately when changes have occurred (including the
operational behaviour)! If necessary, shut the dry extraction down immediately and secure it
against restarting!
1.4.4.4
With malfunctions, shut the dry extraction down immediately and secure it! Have faults eliminated
immediately! Electrical installation works may only be accomplished by trained electrical
personnel.
1.4.4.5
Only use suitable and checked tools.
1.4.4.6
Regular control of the entire system.
1.4.4.
Special work in the context of the use of the machine
1.4.5.1
Adhere to setting, maintenance and inspection activities specified in this operating manual
including data for the exchange of parts/partial equipment! These activities may only be
accomplished by authorised technical personnel.
1.4.5.2
Inform operating personnel before beginning of the execution of special and repair work!
Designate a supervisor!
1.4.5.3
The dry extraction must be switched off with maintenance and repair work and be separated from
the joint cutter.
1.4.5.4
Before cleaning, all openings must be covered and sealed, into which for safety and/or function
reasons no cleaning agent may penetrate. Electric motors, switches and plug connections are
particularly endangered. After cleaning, the covers/adhesions must be removed completely!