Service
48
Grinding machine SBM-XS 300 G1E1 ALU MIX
8.4 Troubleshooting
If the machine is not working or is not working correctly, the following causes
may pertain.
Error Display/behaviour
Cause
Solution
1 Indicator
lamp
"Phase
sequence incorrect" is lit
Phase sequence of the power
supply does not match that of the
machine
Turn phases
May only be removed by an
electrician!
1 phase missing on power
connection
Check phases
May only be removed by an
electrician!
Phase sequence relay defective
Exchange phase sequence relay
May only be removed by an
electrician!
2
Machine does not start
Front EMERGENCY STOP
pushed
Disengage EMERGENCY STOP
Main switch set to 0
Set main switch to 1
Door contact switch defective
Inform electrician!
3
Digital display off
Notify customer service
4
Feed is not running
Feed speed controller set to 0
Increase feed speed
Feed switch set to 0
Turn feed switch to the right
5
Laser not functioning
Laser dirty
Clean laser
Protective cap on the laser
Remove the protective cap