17. SHOWER VALVE
The shower valve can be accessed from the rear of
the shower and is located on the central tower.
The valve is divided into three parts that are joined
together.
The uppermost part is the divertor. There are four
connections able to be made here. One to the
monsoon shower, another to connect to the body
jets, the third connects to the hand shower/riser
bar water inlet and the forth to the bath fi ller.
When making the connections, ensure they are
water tight. Check all pre-fi tted hoses
as these may only be hand tight
during manufacture.
The middle part of the valve handles
the water on and off . There are no connections to
be made here.
The lower part of the valve has three connections
to be made. the HOT and COLD water supplies
from you property connect to the outermost
connections - ENSURE THE FEEDS ARE THE
CORRECT WAY ROUND. The third connection is a
cold water supply from the valve and connects to
the WATER IN on the steam generator.
REMOVE THE WHITE PLASTIC BOX SECTION THAT
MAY BE COVERING THE VALE ACCESS AT THE
REAR - THIS IS FOR TRANSPORT PURPOSES ONLY
AND IS NO LONGER NEEDED.
Cold Water IN from the shower valve
connects to the Steam Generator (your
steam generator may look diff erent
than the image opposite, but the
connections are marked the same).
The STEAM OUT connects to the rear of
the Steam Pod via the INSULATED HOSE
to supply Steam into the shower.
Waste/Drain allows un-used water in
the generator after it is used, to exit into
the underside of the Plug Waste via a
thin grey hose.