4
Maintenance and service
Liquiflo FTS Transfer Pump User Manual
Series No. FTS300
43
Refilling gear oil chamber
1.
Using 6 mm hex key, install oil drain plug, Figure 1
2.
Orient the pump such that the gear oil fill port is on top.
3.
Using a 6 mm hex key, remove the gear oil fill port plug, Figure 2.
4.
Using a Phillips #2 screwdriver, remove the gear chamber vent screw, Figure 2.
5.
Refill the gear oil chamber with 1 quart (900
–950 mL) of Mobil 1™ 5W-30 synthetic motor oil, or an equivalent
SAE 5W-30 product. Liquiflo
FTS recommends Mobil 1™ 5W-30 synthetic for the Transfer Pump for longest
life and highest performance.
6.
Using 6 mm hex key, install oil fill plug.
7.
Using a Phillips #2 screwdriver, install the gear chamber vent screw.
Figure 1
Drain plug
Figure 2
Fill plug
Vent screw